|
Facilità d'uso
Use only the bottles provided. CONTROLS & OPERATION 10) Plug cord into wall receptacle. Your humidifier is now ready for use. The humidifier should be placed at least FOUR inches away from any walls and away from heat registers. Unrestricted airflow into the unit will result in the best efficiency and performance. Set desired levels and speed. 11) Open control panel door by lifting under the tab. Depending on which model, you may have a choice of 2, 4, or variable fan speed allowing you to use the low setting for the quietest operation or a high setting for maximum output. Models 4D7 300 and 800 have a digital humidistat with LCD display. The room’s Relative Humidity (%RH) is displayed at the top and the desired humidity level is displayed at the bottom. The desired humidity level can be manually adjusted between 30 and 90%, using the “Set Humidity” button. 45% RH is the suggested initial setting. 12) All models have an automatic humidistat. The humidistat will turn the humidifier on when the relative humidity in your home is below the humidistat setting and will turn the humidifier off when the relative humidity reaches the humidistat setting. For initial operation, set the humidistat at its midpoint “comfort zone” setting and adjust up or down from there to achieve the desired humidity level. Turning the variable speed humidistat all the way counterclockwise will turn the unit off regardless of the relative humidity. This must be turned on again before the unit will work. 13) The refill light will indicate when the unit is completely out of water. The motor will also shut off. The right bottle will empty first. To refill, see Step 9. **When excessive condensation exists, a lower speed setting is recommended. CAUTION: Disconnect power before filling, cleaning or servicing unit. Keep grille dry at all times. OPTIONAL AIRCARE® FILTER -1051 The first stage of the air filter is a, high-efficiency, electrostatically charged filter media which traps dust, pollen, and airborne pollutants. The second stage of the AirCare filter is an activated carbon media which absorbs odors from cooking, pets, or tobacco smoke. We recommend replacing the AirCare filter at least once a year and more often if necessary. When the white filter media is coated with a layer of dust and dirt, it is time to replace the AirCare filter. The certified water out output of your humidifier will be reduced when using the AirCare filter. AirCare filters are optional and are not required for normal operation of the humidifier. AirCare is a registered trademark of Essick Air Products. CARE AND MAINTENANCE Cleaning your humidifier regularly helps eliminate odors and bacterial and fungal growth. Ordinary household bleach is a good disinfectant and can be used to wipe out the humidifier base and bottle/reservoir after cleaning. We recommend cleaning your humidifier at least once every two weeks to maintain optimum environmental conditions from your humidifier. We also recommend using Essick Air BacteriostatTreatment each time you refill your humidifier to eliminate bacterial growth. Add bacteriostat according to the instructions on the bottle. Please call 1-800-547-3888 to order Bacteriostat Treatment reference part#1970. 1) Turn off unit completely and unplug from outlet. 2) Lift out the water bottle and the power pack. 3) Unplug interlock plug from chassis/power pak receptacle. 4) Lift off end covers and remove both water bottles. Note: Water bottles must be removed before chassis/power pak to prevent possible switch lever damage. 5) Lift chassis/power pak unit from cabinet. REMOVING SCALE 6) Carry base to cleaning basin. Lift the wick from the base allowing excess water to drain. Rinse wick under freshwater only. Do not use soap, detergent, or any other cleaners on the wick. Leave in sink to drain. 7) Empty the water from the base and/or water bottle. Fill the base and/or water bottle with water and 8 oz. (1 cup) of undiluted vinegar. Let stand 20 minutes. Then empty solution. 8) Dampen a soft cloth with undiluted white vinegar and wipe out water bottle and/or base to remove scale. Rinse the water bottle and/or base thoroughly with fresh water to remove scale and cleaning solution before disinfecting. DISINFECTING UNIT 9) Fill the water bottle and reservoir with 1 gallon of water and add 1 teaspoon of bleach to each. Wet all surfaces on water bottle and reservoir only. Let solution stay for 20 minutes, then rinse with water until bleach smell is gone. Dry with clean cloth. The outside of the unit and water bottle may be wiped down with a soft cloth dampened with fresh water. 10) Refill unit and re-assemble per ASSEMBLY instructions. SUMMER STORAGE 1) Clean unit as outlined in Care & Maintenance section. 2) Discard used wicks and any water in the reservoir and allow cabinet to dry thoroughly before storage. Do not store with water inside reservoir. 3) Do not store unit in an attic or other high-temperature area. 4) Install new filter at beginning ...
Questo manuale è adatto anche per i modelli :umidificatori - 4D7 300 (307.76 kb)
umidificatori - 697 500 (307.76 kb)