Log:
valutazioni - 4, GPA: 3.5 ( )

Istruzioni per l'uso Crane, Modello EE-5063

Produttore : Crane
File Size : 379.59 kb
File Nome : crane-ee-5063.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


8. Use the humidity output regulator control knob to adjust the intensity of the vapor output. Turning the knob clockwise will increase the moisture output, turning the knob counterclockwise with reduce the moisture output. (see Fig. 10) Fig. 10 9. When the humidifier runs out of water the power light will turn red, and the mist output will stop. This is a safety feature to prevent the humidifier from possibly over heating and damaging the nebulizer. This safety feature uses a water level sensor to stop the nebulizer once the water level sinks below the required level in the water basin. Turn the humidifier off and unplug before removing and refilling the water tank. Please note that the RED Power Light on the humidifier body will stay on. The (red) light signal indicates that the humidifier is turned on and needs to be refilled. INSERTING HUMIDIFIER FILTER (SOLD SEPARATELY not included with your humidifier) A humidifier filter is an optional accessory for your Crane Cool Mist Humidifier. Filters are used to eliminate white dust caused by hard water and to reduce mold spores and bacteria that can build up in your humidifier. Place humidifier filter in humidifier as shown in Fig. 10A NOTE: Do not leave filter in humidifier longer than recommended time. See Filter instructions. Filters are not included with the humidifier and can be purchased separately. Fig. 10 A SET THE CORRECT HUMIDITY OUTPUT ALWAYS PLACE THE HUMIDIFIER ON AN ELEVATED NON-METALLIC WATERPROOF SURFACE FOR BEST PERFORMANCE. Adjust the vapor control so that the vapor rises up and gets absorbed by the room air. Do not turn on too high output as the vapor cannot be absorbed by the air and accumulates on the surface around the humidifier. If the humidifier is placed near a fan or air conditioning outlet the vapor may be forced down by the foreign air stream. Change the location of the humidifier or reduce the output of the other room conditioning appliances. correct wrong A NOTE ABOUT HUMIDITY .. It is best to keep the humidity level at about 30-50 percent of relative humidity. .. The comfort level of humidity will vary from room to room and with changing room conditions. .. In cold weather, windows and even some walls may fog or develop frost from excessive indoor humidity. If this occurs, reduce the mist intensity setting to avoid damage from condensed water dripping on windowsills. .. Too much humidity in the room may allow moisture to accumulate on surfaces where bacteria and fungi can grow. Moisture that gathers may also damage furniture and walls, especially wallpaper. .. To eliminate excessive humidity, especially in small rooms, leave the room door open and adjust the mist intensity control setting. MAINTENANCE CAUTION: Always be sure that the appliance is unplugged and switched OFF before cleaning or attempting to store the item. NEVER PLUG OR UNPLUG UNIT WITH WET HANDS. DO NOT leave water in water tank or water basin when unit is not in use as it may result in the build up of mineral deposits and bacteria that can inhibit the output efficiency of the humidifier. PLEASE NOTE that if water remains in the water tank for more than a day or two, bacterial growth is possible. ALWAYS use fresh cool water when using unit. NOTE: When removing water tank, water may accumulate under vapor lid and on the bottom of the water tank. It is recommended to have a dry cloth ready to dry wet surfaces. DISINFECTING THE WATER TANK AND WATER BASIN 1. Fill water tank with 1 teaspoon of household bleach in 1 gallon of water. Let stand twenty minutes, shaking vigorously with two hands every few minutes, drain and rinse with clean water until the bleach smell is gone. Dry with a clean cloth or paper towel. 2. Wipe the water basin with a soft cloth dampened in the bleach and water solution. Rinse the water basin with cool water to remove any bleach smell. DO NOT IMMERSE WATER BASIN IN WATER. 3. Wipe all exteriors surfaces of the base with a soft, dry cloth. Do not immerse the base in water or use water to clean the base. An electric shock may result or the humidifier may be damaged. NOTE: It is recommended to clean humidifier with water and bleach solution as stated above after using the humidifier the fourth time. GENERAL MAINTENANCE AND CLEANING Before any cleaning operation, switch the humidifier off and unplug it. 1. Always unplug the unit before cleaning. 2. The humidifier must be drained and cleaned before storing. 3. Once unplugged the exterior of the unit may be cleaned by wiping with a dry cloth. Caution: The ON/OFF switch must be thoroughly dry before unit is again plugged into power source. 4. There may be some lime deposits in the nebulizer, particular in areas with hard water. Overcome this drawback by cleaning the nebulizer with water and vinegar on a soft cloth regularly, as follows: A. Dampen a cloth with vinegar and wipe the nebulizer gently, until the lime deposits disappear completely. B. Rub down gently with a dry cloth and remove remains of hu...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie