|
Facilità d'uso
4. You may fill your Recirculating Evaporative Humidifier two different ways: A) Fill the Base with cool water to level indicated in Figure 2A. B) Replace the Upper Housing on the Base and push Water Lens down to pour water into the Humidifier (Figure 2B) until it reaches the level indicated in Figure 2A. Do not overfill and never use hot water. CAUTION: Do not pour water through the Exhaust Grill on the Upper Housing. Doing so may cause damage and personal injury. Do not overfill. Overfilling the Unit may cause motor damage. Always carry filled Humidifier carefully. Never move water filled Humidifier while plugged in. OFF SEASON STORAGE 1. Clean and dry Humidifier thoroughly per the CLEANING and FILTER CARE section. Do not leave any water in the Unit while storing. 2. Dispose of the Evaporative Pad. Do not store a used Evaporative Pad in the Humidifier. Do not dispose of Pad Holder. 3. Place Humidifier back in its carton and store in a cool dry place. CLEANING and FILTER CARE 1. Regular cleaning is necessary to ensure proper and efficient operation. The frequency of cleaning depends on the amount of impurities which may be found in the water or how often the Humidifier is in operation. In either instance, it is recommended that the Humidifier be cleaned at least once a week. CAUTION: To prevent electric shock, always turn Control Knob to OFF (0) position and unplug before cleaning. 2. Remove Upper Housing from Base. Be careful not to let excess water from pump spill onto furniture or flooring. 3. With water lens pushed down, the filter may be removed for cleaning or replacing. (Figure 4) 4. Remove Evaporative Pad Holder from Base and inspect Small Water Drip Holes for any blockage. (Figure 5) It is important that these Drip Holes remain open at all times for proper water supply to Evaporative Pad. 5. To increase the life of your Evaporative Pad, unsnap Holder, remove Pad and flip over. (Figure 6) Evaporative Pad life may be extended by cleaning the Pad in a vinegar solution. To clean Pad, mix one part undiluted vinegar with four parts warm tap water. Soak the Pad in this solution for 20 minutes, rinse Pad thoroughly with warm water to remove vinegar odor. DO NOT FLATTEN, SQUEEZE OR TWIST FILTER WHEN CLEANING. 6. Discoloration of the Evaporative Pad is normal after extended use. The discoloration is caused by mineral deposits in the water, and the degree of discoloration will vary depending upon the amount of mineral content in the water. When the Pad surface area is thoroughly discolored, or you notice reduced water usage, it is a good indicator that the Evaporative Pad needs to be replaced. The Evaporative Pad should be replaced at least once every season. The Replacement Pad to be used in this unit is: The Replacement Evaporative Pad Model 9932 (Available Separately) 7. TO DESCALE BASE AND DRIP SHIELD: Mix one part undiluted white vinegar with four parts warm tap water. Let vinegar solution stand for 20 minutes then wipe away any scale buildup using a soft brush or cloth. Do not use soap or detergents and never use an abrasive cleaner. 8. TO DISINFECT BASE AND DRIP SHIELD: Fill with 1 teaspoon of chlorine bleach and 1 gallon of water. Let solution stand for 20 minutes. Carefully empty Jug and rinse well with water until bleach smell is gone. TROUBLE PROBABLE CAUSE SOLUTION Foul odor • Filters need to be replaced Replace Filter • Base/reservoir needs to be cleaned Follow Instructions under CLEANING and FILTER CARE • Whole humidifier needs cleaning Follow Instructions under CLEANING and FILTER CARE Filter discoloration • Mineral deposits in water Replace Filter Water discoloration • Humidifier needs to be cleaned Follow Instructions under CLEANING and FILTER CARE • Hard water - Iron in water Use filtered or distilled water • Some humidifier additives can cause discoloration No water show • No water in Humidifier Fill with cool water • Hose not connected to water show Connect Hose to Water Show • Hose not connected to pump Connect Hose to Pump TROUBLE SHOOTING GUIDE Figure 3 HIGH (3): For fast humidification of a large room. This setting will provide approximately 3 gallons of moisture output in a 24 hour period.* MED (2):For normal operation. LOW (1):For quiet, night time operation. * Calculations based on ambient conditions of 70° F and 30% relative humidity in a room of average insulation. 8. Water usage will vary depending upon initial humidity level in the room. If humidity is low, the Unit will use water more rapidly until the humidity in the room is stabilized. If the humidity is already near or above 50% relative humidity, water consumption will be low. CAUTION: Be careful not to direct airflow towards walls or furniture, as excessive moisture may cause damage. 9. Refill Humidifier when water level in the Base is low. 10. If you do not plan to use your Humidifier for several days, empty all water from the Unit. Standing water may provide an environment for the growth of algae. 5. Take extra care to ...
Questo manuale è adatto anche per i modelli :umidificatori - 9915A (415.36 kb)