Istruzioni per l'uso Bionaire, Modello BWM8305C

Produttore : Bionaire
File Size : 308.94 kb
File Nome :
Lingua di insegnamento: plsvenesfrdenldafi
Vai a scaricare



Facilità d'uso


The AccuSet Plus™ Digital Humidistat will automatically turn the humidifier ON or OFF, depending on the preset comfort level. The comfort level ranges from 30% to 65% relative humidity. MANUAL MODE NOTE: After starting the unit from cold, it will take 5–10 minutes before any noticeable steam is emitted from the Outlet Grill. 1. When plugged in, the Display will show the current room humidity. 2. Press the Button once and the Display will show OFF (OF) . 3. To start the unit, push the MODE/OFF Button again for the LOW (LO) manual setting. After 2 seconds, the Display will return to show the current room humidity. 4. Press the Button again for the HIGH (HI) manual setting. After 2 seconds, the Display will return to show the current room humidity. 5. To stop the unit, keep pressing the Button until the Display reads OFF (OF). AccuSet Plus™ HUMIDISTAT MODE To take advantage of the AccuSet Plus™ Digital Humidistat 1. Press the MODE/OFF through Manual LO/HI until the speed is set in either the AUTO LOW (AL) or AUTO HIGH (AH) setting. 2. Adjust the set humidity by using the Up and Down Buttons. The Display will show a setting in the range 30% – 65% and the humidity can be increased/decreased in increments of 5%. When the humidity level is set, the Display will return to show the current room humidity. When the room humidity level rises above the set humidity, the Humidifier will stop. When the humidity level drops below the set humidity, the Humidifier will turn on automatically. NOTE: The AccuSet™ Humidifier has memory. This means that when you turn the AccuSet™ mode, it will remain Humidifier was previously set has been unplugged. RESET PROCEDURE NOTE: When the Water Tank is empty and the 3 BWM8305/8305CI/IUK04M1 V.qxd 4/30/04 17:00 Page 9 water in the Heating Chamber is almost empty, the Red RESET light will illuminate and the Automatic Shut Off will activate. The unit will not operate again until you refill the Water Tank and reset the Humidifier as follows. 1. Unplug the unit. 2. Remove and refill the Water Tank, being sure to follow the Maintenance Instructions. Replace the Tank onto the Base. 3. Wait 5 minutes for the Automatic Shut-Off to reset. 4. After the 5 minutes, plug in the unit and turn the unit on. The RESET light should now be off (if not repeat steps 1 through 4). In about 5 minutes, the Humidifier will begin to produce moisture. If you do not plan to use the Humidifier for two or more days, make sure any residual water is drained from the Water Tank and Base to prevent algae or bacteria growth. USING THE PROGRAMMABLE TIMER AccuSet Plus™ allows the user to program the Humidifier to come on at a preset time, or turn off after a set amount of time. Setting the Off Timer: 1. Select the Mode and temperature you wish the Humidifier to run in. 2. While the Humidifier is running, press and hold the Up and Down Buttons simultaneously for 2 seconds. The display will flash "00". 3. By pressing the Up and Down Buttons, program the Humidifier to turn off up to 16 hours later in increments of 1 hour. 4. After setting the timer, the display will return to show the current room temperature. An indicator on the display will illuminate to show that the timer is activated. 5. After the predetermined length of time has passed, the Humidifier will automatically shut off. Setting the On Timer: 1. While the Humidifier is off, press and hold the Up and Down Buttons simultaneously for 2 seconds. The display will flash "00" . 2. By pressing the Up and Down Buttons, program the Humidifier to turn on up to 16 hours in advance in increments of 1 hour. 3. After the preset length of time has passed, the Humidifier will automatically turn on in Auto Mode HI at 45%. CLEANING AND MAINTENANCE INSTRUCTION The following maintenance procedures must be routinely followed in order to ensure proper, efficient operation of your humidifier. The unit WILL FAIL if it is not cleaned properly. Regular cleaning prevents scale build-up on the heating element and tray. It also prevents microorganisms from growing on the tray and tank. This ensures that maximum efficiency will be achieved. We cannot over-emphasize how essential proper cleaning is to the maintenance and continued use of your unit and the avoidance of algae or bacteria build-up. Regular Maintenance 1. Be sure the unit is OFF and is disconnected from the electrical outlet. 2. Remove the Water Tank then unlock the Housing by moving the two Locks towards the front of the humidifier. Lift the Housing from the Base. 3. Empty water and minerals from the Base and place in the top rack of the dishwasher. NOTE: the Base is dishwasher safe TOP RACK ONLY. 4. Drain the water from the Tank into the sink and rinse tank thoroughly. Leave to dry. 5. Wipe the Heating Element clean with a soft cloth after it has had a chance to cool. The Electronic Thermal Control Heating element is lined with a Teflon® coating that is designed to provide the easiest cleaning and prolong the operating efficiency ...

Questo manuale è adatto anche per i modelli :
umidificatori - BWM8305 (308.94 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie