The desired humidity level can be manually adjusted between 30 and 90%, using the “Set Humidity” button. 45% RH is the suggested initial setting. 17) The automatic humidistat will turn the humidifier ON when the relative humidity in your home is below the humidistat setting and will turn the humidifier OFF when the relative humidity in the room exceeds the humidistat setting by 6% R.H. This will reduce rapid cycling. When the humidifier is running, you will feel cool, invisible, humid air exiting from the outlet grill. 18) When first plugged in, the display will show the current % Room Humidity and will default to 45% Set Humidity. If there is no water in the cabinet, the red “Refill” indicators will be lit and the fan motor will not run. Fill both water bottles, following the “Filling Water Bottles” instructions. When the bottles have been filled, the LCD display will initiate with a segment display test, the Room and Set humidity % will be displayed, and the fan speed will be shown as OFF. FAN SPEED 19) The fan speed can be set to the desired airflow level by pressing the “Set Speed”, (left), button. The Green power indicator will be lit. To increase fan speed, repeatedly press the “Set Speed” button. A bar segment indicator at the left side of the display will indicate increasing fan speed. After the HIGH fan speed has been reached, the next press of the button will return back to the LOWEST fan speed. To turn the humidifier OFF, press AND HOLD the “Set Speed” button down for two seconds. HUMIDITY SETTING 20) If the room humidity is lower than the Set Humidity, the fan motor will start and run until the room humidity exceeds the Set Humidity by +6% R.H. If higher than the Set Humidity, the fan motor will not start. The desired humidity level can be changed with the “Set Humidity”, (right), button. Press the button once, and the display will flash. Repeatedly pressing the button will increase the Set Humidity in steps of 5% RH. When the desired humidity level is reached, (between 30 – 90 % RH), release the button. If the button is released and then held down while flashing, the display will auto-advance through the range. Release the button to exit the auto-advance mode. BOTTLE REFILL SYSTEM 21) When one bottle empties, one red refill indicator light will light, and the fan will continue to run. When the water bottles are both empty, the two red refill indicator lights will be lit and the fan motor will stop. 22) After the “Set Humidity” button has been inactive for three seconds, the control will exit the Set Mode with the last programmed number remaining on the display. NOTICE: Under certain conditions, cold objects in the room, such as windows and outside walls, may cause moisture to condense. Severe condensation on window sills and walls may result in water damage. When these conditions exist, a lower humidistat setting is recommended. Air Care® Filter MODELS 4D7 800, 497 800, 497 300, 447 401, 447 301 AND 427 300 Air Care® models feature a...
Questo manuale è adatto anche per i modelli :umidificatori - 447 301 (321.06 kb)
umidificatori - 427 300 (321.06 kb)
umidificatori - 447 401 (321.06 kb)
umidificatori - 497 300 (321.06 kb)