Log:
valutazioni - 3, GPA: 4.3 ( )

Istruzioni per l'uso Bionaire, Modello BCM7307

Produttore : Bionaire
File Size : 334.15 kb
File Nome : 510ee448-ba0a-4a57-94b5-23d7c4d44c44.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


2. Remove the housing and the reservoir from the humidifier and place in sink or tub. 3. Carry the base of the unit to the sink, remove the wick holder and wicks, place in sink, drain any remaining water and rinse thoroughly to remove any sediment or dirt. Wipe clean, and dry with a clean cloth or paper towel. NOTE: the base and wick holder are dishwasher safe TOP RACK ONLY. 4. Drain the water from the reservoir into the sink and rinse reservoir thoroughly. Wipe clean, and dry with a clean cloth or paper towel. 5. Put filters back in wick holder, replace on base, replace the housing, then refill reservoir with cool tap water as instructed earlier in the Filling Instructions. Do not overfill. 6. Follow Operating Instructions. WEEKLY MAINTENANCE To Remove Scale: 1. Repeat steps 1-4 in the Daily Maintenance section. 2. Clean the base by partially filling the base with one 8-oz cup of undiluted white vinegar, or by using Clean-AwayTM (model DMS216) by the manufacturer. Leave this solution in the base for 20 minutes, while cleaning all the interior surfaces with a soft brush. Remove base scale by wiping the base with a cloth dampened with undiluted white vinegar. 3. Rinse with clean warm water to remove the cleaning solution before disinfecting the reservoir. To Disinfect Humidifier Base and Reservoir: 1. Fill humidifier base with 1/4 gallon of water and 1/2 teaspoon of chlorine bleach. 2. Fill the reservoir 1/2 full with water and 1/2 teaspoon of chlorine bleach. 3. Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces. 4. Carefully empty the base and reservoir after 20 minutes, and rinse with water until you cannot detect any bleach smell. Dry with a clean cloth or paper towel. 5. Refill the water reservoir as directed with cool tap water, replace the humidifier housing, and turn the unit on. STORAGE INSTRUCTIONS When not using your humidifier for an extended period of time: 1. Dispose of the filters. DO NOT leave in unit. 2. Clean, rinse and thoroughly dry the humidifier as directed in weekly maintenance. DO NOT leave any water in the unit when storing. Leaving water in the unit may render the unit inoperable for the following season. 3. Place the humidifier in the original carton and store in a cool, dry place. 4. Order your replacement filter for next year’s use. Frequently Asked Questions Question Answer • What are the variables that The estimated run time for this humidifier is based on affect run time? average room conditions. The actual run time of your humidifier is dependent on numerous variables such as: Air exchange in the room where the humidifier is placed. Room construction of the room where the humidifier is placed. Temperature of the room where the humidifier is placed. Humidity levels in the room where the humidifier is placed. . Movement of occupants and the opening and closing of doors in the room where the humidifier is placed. Home furnishings in the room where the humidifier is placed. • How do I remove film on See Daily Maintenance instructions. Regular cleaning is water tank? recommended. • How can I extend the run Run your unit on the lowest setting. time? . If your unit has electronics, set it to your desired humidity level. The unit will turn on and off, which will extend the run time. . Fill the tank all the way full, place it on the base, let the water empty into the base until it stops bubbling, then refill he tank full again. This ensures maximum water capacity and will extend run time. Troubleshooting for your Cool Mist Humidifier Trouble • LED not illuminated. • Mist output minimal to none. • Water leaks from water reservoir. • Filter turns brown. • Water in reservoir appears cloudy. • Humidistat cycles on/off. • Very tight reservoir cap. • FilterCheck® is not working. • Humidifier continuously displays 21%. • Humidifier continuously displays 90%. Probable Cause Unit not plugged in. Power failure. Filter has not absorbed water. Mineral buildup in base. Humidistat is set too low. Filter needs to be replaced. Normal operation. Rubber O-ring is missing or improperly placed. Reservoir cap not tight enough. The filter needs to be replaced. Short filter life. Filter needs to be replaced. Humidifier is reacting to room humidity level. Over tightened. Takes 60 minutes to register. Humidity at the humidifier is at or below 21%. Humidity at the humidifier is at or above 90%. Solution Plug in unit. Check circuit breaker or outlet. Wait 30 minutes before starting humidifier. Regular cleaning of tray after each use will help keep the unit functioning properly. Set the humidistat to high. Replace your filter (BWF100) by calling 1-800-253-2764, or visiting Mist is invisible. Check to see if inlet or outlet grills are blocked. Remove reservoir cap then replace or reposition ring. Tighten the reservoir cap. Replace your filter (BWF100) by calling 1-800-253-2764, or visiting In areas with hard ...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie