5. Remove the black plastic distribution tray (5) from the evaporative assembly by unsnapping the white plastic holding strips from the tabs at the end of the tray. Lightly scrape out any calcium deposits and clean the “V” notches (6), but do not scrape off the granular coating from the bottom. This textured surface helps ensure even water flow for maximum performance. See page 2 if removed. 6. Slide the Water Panel evaporator (7) out from the white plastic Scale Control Insert (8). Clean the Sc
Soaking the tray in vinegar or a lime-removing agent is helpful when trying to remove stubborn mineral deposits. For trays with granular coating: Do not scrape off the granular coating, but lightly scrape out any mineral deposits and clean the “V” notches. This textured surface helps ensure even water flow for maximum performance. See page 3 if removed. 6. Slide the Water Panel evaporator (7) out from the plastic Scale Control Insert (8). Clean the insert frame by twisting and flexing it to loos
5. Remove the black distribution tray (4) from the evaporative assembly (3) by unsnapping the white plastic holding strips from the tabs at the end of the tray. Lightly scrape out any calcium deposits and clean the “V” notches (5) but do not scrape off the granular coating from the bottom. This textured surface helps ensure even water flow for maximum performance. 6. Slide the Water Panel evaporator (6) out from the white plastic scale control insert (7). Clean the insert frame by twisting and f
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Materials Provided and Not Provided . . . . . . . . . . . . . . . . . . 3 Electrical Specifications, Capacities and Weights . . . . . . . . 4 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Overview of Humidifier Operation . . . . . . . . . . . . . . . . . . . . . 7 INSTALLATION Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Setting Slide Switches. . . . . .
................................................................................................................................................................................ AIRFLOW PROVING SWITCH INSTALLATION INSTRUCTIONS Description: FIGURE 20 The airflow proving switch is a safety device that will prevent the humidifier from producing steam when there is no airflow present in the HVAC system. The switch is a pressure differential measuring device that determines if there is airflow present
For multiple lamps, the reading would be a multiple of this value, i.e., with two lamps installed, the amp reading will be at least 300 mA. f. If the lamp is operating correctly, remove the ammeter from the wiring and put back any access panels that were removed during this procedure. If the lamp is not operating correctly, refer to the ‘Troubleshooting’ section of this manual. Note: If other electrical components or accessories share the same circuit as the UV lamp(s), the current draw will be
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 II. Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 III. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Installation of External Mount Rooftop Units (Models 1952 & 1953) . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Installation of Internal Mount Rooftop Units (Model 1972) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The Automatic Humidifier will accurately control the humidity in your home to a maximum of 45% RH and a minimum of 10% RH. The values of outdoor temperature and dial settings may fall in between or outside of the listed values in Table 2. In these cases, you can only approximate your home’s actual indoor RH. - 4 To check the humidifier’s operation, note the current setting and set the Automatic Humidifier Control to the test mode when the furnace blower motor is operating. Water will flow into t
To remind yourself when you put the ISS into operation, please check the current month on the stamp and write the current year on the line provided. Water Quality Maintenance The Ionic Silver Stick® (ISS) keeps the water free of microbial growth. The ISS uses the anti-microbial effect of silver to prevent the growth of microbes in the water base. It begins to function as soon as it comes into contact with water, even if the unit is switched off. The Ionic Silver Stick should be changed every yea
5 Setting up the Tripod .................................................................................................................. 5 Attaching the Telescope Optical Tube to the Tripod.................................................................. 6 Moving the Travel Scope Manually ........................................................................................... 6 Installing the Diagonal & Eyepiece ..............................................................................