Log:
valutazioni - 1, GPA: 4 ( )

Istruzioni per l'uso AEG, Modello HG654440SM

Produttore : AEG
File Size : 622.62 kb
File Nome : 201901EN.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


• Make sure that there is an access to the mains plug after installation. • Do not pull the mains cable to disconnect the appliance. Always pull the mains plug. • The appliance must not be connected with an extension cable, an adapter or a multiple connection (risk of fire). Check that the ground connection is in conformity with the standard and regulations force. • The power cable must be placed in such a way that it does not touch any hot part. • Connect the appliance to the mains with a device that lets to disconnect the appliance from the mains at all poles with a contact opening width of minimum 3 mm, eg. automatic line protecting cut-out, earth leakage trips or fuse. • None of a parts of the connection cable can not get a temperature 90°C. Electrical Requirements Any permanent electrical installation must comply with the latest I.E.E. Regulations and local Electricity Board regulations. For your own safety this should be undertaken by a qualified electrician, e.g. your local Electricity Board, or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting (NICEIC). The manufacturer declines any liability should these safety measures not be observed. 10 10 Installation This hob is designed to be connected to a 230 V 50 Hz AC electrical supply. Before switching on, make sure the electricity supply voltage is the same as that indicated on the hob rating plate. The rating plate is located on the bottom of the hob. The hob is supplied with a 3 core flexible supply cord incorporating a 3 amp plug fitted. In the event of having to change the fuse, a 3 amp ASTA approved (BS 1362) fuse must be used. 123451 Green and Yellow 2 3 amp fuse 3 Brown 4 Cord clamp 5 Blue Should the plug need to be replaced for any reason, the wires in the mains lead are coloured in accordance with the following code: Green and Yellow -Earth Blue -Neutral Brown -Live 1. Connect the green and yellow (earth) wire to the terminal in the plug which is marked with the letter 'E' or the earth symbol or coloured green and yellow. 2. Connect the blue (neutral) wire to the terminal in the plug which is marked with the letter 'N' or coloured black. 3. Connect the brown (live) wire to the terminal in the plug which is marked with the letter 'L' or coloured red. Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath. A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard. Ensure that the cut off plug is disposed of safely. The replacement of electric cable must be carried out exclusively by the service force centre or by personnel with similar competencies, in accordance with the current regulations. Installation 11 Replacement of the connection cable To replace the connection cable use only H05V2V2-F T90 or equivalent type. Make sure that the cable section is applicable to the voltage and the working temperature. The yellow/ green earth wire must be approximately 2 cm longer than the brown (or black) phase wire. Building In min. 55 mm min. 650 mm 560 mm min. 450 mm 30 mm 480 mm min. 600 mm 10 mm 11 mm 11 mm A 3 mm A - supplied seal A B A - supplied seal B - supplied brackets Possibilities for insertion Kitchen unit with door The panel installed below the hob must be easy to remove and let an easy access in case a technical assistance intervention is necessary. min 20 mm (max 150 mm) 30 mm 60 mm b a a) Removable panel 12 12 Product description b) Space for connections Kitchen unit with oven The hob recess dimensions must obey the indication and the kitchen unit must be equipped with vents to let a continuous supply of air. The electrical connection of the hob and the oven must be installed separately for safety reasons and to let easy remove oven from the unit. 50 cm2 360 cm2 180 cm2 120 cm2 MANUFACTURER: ELECTROLUX ITALIA S.p.A. C.so Lino Zanussi, 30 33080 PORCIA (PN) -ITALIA PRODUCT DESCRIPTION Cooking surface layout 3121 Cooktop 2 Semi-rapid burner 3 Triple Crown burner 4 Auxiliary burner 5 Control knobs 45 Control knobs Symbol Description no gas supply / off position ignition position / maximum gas supply minimum gas supply OPERATION Ignition of the burner WARNING! Be very careful when you use open fire in kitchen environment. Manufacturer decline any responsibility in case misuse of the flame Always light the burner before you put cookware. To light the burner: 1. Turn the control knob counterclockwise to the maximum position ( ) and push it down. 2. Keep the control knob pushed for approximately 5 seconds; this will let thermocouple to warm up. If not, the gas supply will be interrupted. 3. Adjust the flame after it is regular. If after some tries the burner does not light, check if the crown and its cap are in correct positions. Each control knob has a pilot light. It lights up when you turn the control knob. 3 4 2 1 1 2 3 4 Operation 13 14 14 Helpful hints and tips 1 2 3 4 Burner cap Burner crown ...

Questo manuale è adatto anche per i modelli :
Piani di cottura - HG654440SM (622.62 kb)
Piani di cottura - HG654440SM (622.62 kb)
Piani di cottura - HG654440SM (622.62 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie