and who will comply with the I.E.E. and local regulations. The wires in the mains lead of this appliance are coloured in accordance with the following code: Green & Yellow = Earth, Blue = Neutral, Brown = Live. As the colours of the wires in the mains lead for the appliance may not correspond with the coloured markings identifying the terminals connecting to the fuse spur, proceed as follows: • The wire which is coloured green and yellow must be connected to the terminal marked E (Earth) or coloured green. • The wire which is coloured blue must be connected to the terminal marked N (Neutral), or coloured black. • The wire which is coloured brown must be connected to the terminal marked L (Live), or coloured red. Note: Use a 3A Fuse Assembly and electrical connection should be carried out by specialised personnel. When installing this product we recommend you seek the help of another individual. DOUBLE POLE SWITCHED FUSE SPUR OUTLET USE A 3 AMP FUSE Gas Supply Requirements IMPORTANT: THIS APPLIANCE SHOULD BE FITTED BY A GAS SAFE REGISTERED FITTER OR OTHER SUITABLY QUALIFIED PERSON. • This installation must comply with the Gas Safety (installation and use) Regulations 1984. • This appliance is category II2H3+ and is designed for use in the UK and Ireland. The installation must comply with the Gas Safety (installation and use) Regulations 1984. • The CDA Group Ltd is not legally able to provide any assistance in the installation of gas appliances except to Gas Safe registered installers. Any Gas Safe registered fitter requiring help must provide their name, address and registration number. Information supplied will be validated before help is provided. • This appliance is suitable for conversion to Liquid Petroleum Gas (G30 or G31). A kit is provided. Do not attempt to fit the conversion kit yourself. • This appliance is adjusted for natural gas (G20) at 20mbar only. • In the event that this appliance is not installed in accordance with the above requirements, the appliance may be disconnected from the mains gas supply until any faults are rectified; this is a legal requirement. • This appliance should be installed using 15mm copper pipe connected via a shut-off valve in an adjacent unit. The shut-off valve needs to be accessible in an emergency or for service purposes. • This appliance must not be connected to a combustion gas recovery scavenging system • The connection to the gas supply must comply with all current regulations in force. • We are not legally able to offer advice on the installation of gas appliances to non Gas Safe registered personnel. Ventilation All rooms require a window or equivalent (e.g. a door) which can be opened. Some rooms require a permanent vent in addition to a window (see below). This unit must not be used in a room which is less than 5m3. The following table details the requirements based on the kitchen volume (L x W x H) in m3. Room Volume (m3) Air Vent Required (cm3) 5 100 6 to 10 50 6 to 11 No permanent vent required if a door opens to the outside 11 or more None required The above requirements also allow use of a gas oven and grill but if there are any other fuel burning appliances in the same room, consult the relevant British Standard (BS5440) or Gas Safe document. Natural Gas to LPG Conversion This hob can be converted from natural gas to propane operation at a nominal inlet pressure of 37mbar, or butane operation at a nominal inlet pressure of 28/30mbar. This conversion must only be carried out by a competent person (i.e. a Gas Safe registered fitter). Instructions to fit replacement injectors: 1. Disconnect the appliance from the gas and electrical supplies. 2. Remove burner components and pan supports. 3. Remove the injectors and replace with the corresponding injector as shown in the table below. Setting up minimum flow rates: 1. Remove the control knobs. 2. Turn on the LP gas supply, light the burners and turn the controls to the minimum position, as indicated by the small flame. 3. Insert a 2.5mm screwdriver into the hole at the top of the tap and turn the adjustment screw fully clockwise as shown in figure 6. 4. Turn the controls to maximum position then quickly to the minimum position - make sure the flame does not extinguish. 5. Replace the knobs. LPG to Natural Gas Conversion This hob can be converted from propane operation at a nominal inlet pressure of 37mbar or butane operation at a nominal inlet pressure of 28/30mbar to natural gas at 20mbar. This conversion must only be carried out by a competent Required: • 7mm AF nut spinner• Replacement injectors • LPG identity plateRequired: • 7mm AF nut spinner• Replacement injectors • NG identity plateBurner Rapid Semi-Rapid Auxiliary Natural Gas Injector 115 95 69 LPG Injector 85 65 50 Burner Triple Ring Semi-Rapid Auxiliary Natural Gas Injector 130 95 69 LPG Injector 95 65 50 Fig.6 person (i.e. a Gas Safe registered fitter). HCG601 HCG611 / HCG621 Fitting the Hob Unpacking the hob: Take care not to lose or mishand...

Questo manuale è adatto anche per i modelli :
Piani di cottura - HCG601 (534.5 kb)
Piani di cottura - HCG621 (534.5 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie