|
da questo dispositivo ha anche altre istruzioni :
Facilità d'uso
When connecting the appliance, ensure the earth wire is connected first and that all wires are connected to the correct terminals. If a direct connection to the mains is required, it is necessary to install a device that ensures an omnipolar disconnection from the mains, with an opening distance of the contacts such as to ensure the complete disconnection in the conditions foreseen by the category of overvoltage III, as per the installation’s regulation. This is not the case if the connection is by means of a plug, provided the user has easy access to the plug itself. Fuse rating: 3 Amp. When connecting the appliance please ensure that the earthing wire is properly connected. In the event of an accident due to the fact that the appliance is not earthed, or that the earthing is faulty, we do not accept any form of responsibility. The type of cable connecting the appliance to the electricity supply must be H05RR-F3 G 0.75. In the event that the connecting cable must be replaced due to damage only this type of cable should be used. This should only be carried out by one of our after-sales service technicians. CE: This appliance complies with the following EU directives: -72/23/EEC - Low Voltage Directive -89/336/EEC - EMC Directive -90/396/EEC - Directive on Gas Appliances Gas connection (for the fitter) The gas supply system must comply with the local standards in the country in effect. Attach the elbow coupling to the appliance gas supply, using the seal provided. Your hob is pre-mounted with the connection ISO 7-1. In order to change the elbow coupling (see picture 4) Picture 4 In compliance with the currently effective regulations, the hob must be connected to the gas pipe with a stop valve. This valve must be easily accessible at all times. After connecting the unit to the gas mains always check the seal of the connection using a solution of soapy water. Never check the seal using a flame. Using flexible pipes: • do not allow the pipes to be constricted or crushed; • the pipes must not be subjected to traction or twisting forces; • do not allow the pipes to come into contact with cutting or sharp edges, etc... • do not allow any gas connecting pipe and/or any electric connecting wire to come into contact with the bottom of the hob; make sure that the entire length of the pipes and/or electric connecting wire is available for inspection. Particular care must be taken to ensure leak proof connection. The maximum permissible length of the gas connecting pipe is 2.5 m. IMPORTANT!!! This safety gas tube must be routed in such a way that it is not fed through hot areas and does not come into contact with any hot parts of the appliance, e.g. underside of hob. Installation of the tube must ensure that it runs freely and that it cannot come into contact with any movable parts of the kitchen cabinets, e.g. a drawer. Only switch on the circuit breaker or main switch Caution once the appliance has been installed. The appliance must be installed in the furniture in accordance with these operating, installation and maintenance instructions. It is important to note that we shall accept no liability for damage which is a direct or indirect result of improper connection or installation. The appliance must always be disconnected from the mains before repairs are carried out. If repairs are needed, never open the appliance yourself, but call our after-sales service. Particular care must be taken to ensure leak-proof connection! Gas connection may only be completed by an approved fitter in accordance with applicable regulations. In addition, local regulations and the requirements of the local gas supply company must also be observed. This guarantees that the regulations and the local supply company's requirements are observed. Converting the burners to another type of gas (for the fitter) Picture 5 Picture 6 Nozzles for conversion to LPG are provided with this appliance or can be obtained from the after sales service (see list included). Prior to making the necessary adjustments, the hob must be disconnected from the mains. To see which gas type has been preset in the factory; refer to the rating plate in this manual or on the underside of the hob. CHANGING THE NOZZLES The burners are adaptable to different types of gas by replacing only the nozzles for the type of gas used (see data table). To access the nozzle, simply remove the cap and flame-breaker. To change the nozzles, use a no. 7 socket wrench (picture 5). REGULATION OF MINIMUM FROM LPG TO NG Our taps are suitable for all types of gas and are regulated at the minimum as follows: 1. Light the burner and turn the knob to the minimum position. If the flame should go out, proceed as follows: a.) light the burner at maximum capacity (large flame) b.) remove the knob c.) introduce a small screwdriver in hole B on the shaft of the tap (picture 6) and unscrew the adjustment screw by two turns. d.) replace the knob and turn to the minimum position (small flame) 2. Remove the ...
Questo manuale è adatto anche per i modelli :Piani di cottura - ER37353EU/02 (302.87 kb)