|
Facilità d'uso
This gas hob conforms to the categories that are specified on the rating plate. The rating plate can be found on the appliance and additionally on the enclosed addendum sheet. By replacing nozzles, it is possible to set the appliance to any gas listed on the rating plate. If the data should not agree, the appliance must be set to the required gas type and the available pressure. As this gas hob is not intended for connection to an exhaust gas system, pay attention to the applicable installation conditions. Note on ventilation: To ensure good combustion, the room in which this appliance is installed must have a minimum volume of 10 m3 and a door that opens out to outdoors or a window that can be opened. The appliance may be installed in kitchen combinations made of wood or similar combustible materials without taking additional measures. The rear wall must consist of non-combustible material. A minimum distance of 150 mm from heat-sensitive items of furnishing or contact surfaces (cupboard side panel) must be observed. The hob conforms to appliance class 3 and must be installed in the worktop as shown in the installation sketch. The distance between the suspended cupboard and the worktop must be at least 600 mm. Attention must be paid to the manufacturer's specified safety clearance when a vapour extractor is installed. Wall trims must be heat-resistant, and the minimum distance between the hob and the wall trim is at least 35 mm. After unpacking, check the appliance for any transportation damage and report this immediately to the transportation company. Technical modifications reserved. TYPE HLVG232... RK VG 232-... FDxxxx Made in ... AC 220-240V 50/60Hz 0.8 VA Qn LNG 4 050 kcal/h LPG 337 g/h 7.2 Connecting the appliance 40 73 Fig. 7 Seal 1/2 ” Gas connection The gas connection must be in a location that permits access to the shut-off valve and which, if applicable, is visible after opening the door of the furniture item. By means of the included R 1/2" connection bracket (on the appliance end) with the affiliated washer, the appliance must be connected to a fixed connecting line or a gas safety hose to DIN 3383 Part 1 that corresponds to the type concerned. An ambient temperature of 70 °K must not be exceeded if the gas safety consists only partly of metal. The permissible ambient temperature for a gas safety hose that consists completely of metal is 115 °K. If a flexible line is used, it must be laid in such a way that it cannot come into contact with moving parts of the kitchen element (e.g. drawer). Electrical connection Electrical connection (AC 220-240 V) is established by means of a connecting cable with an earthing contact plug connected to an earthed socket, which must also be accessible after installation of the gas hob. If, after installation of the gas hob, not all poles can be isolated from the mains by removing the plug, an isolating device with a contact gap of at least 3 mm must be permanently installed. When establishing connections, make sure that the connecting lead cannot come into contact with hot parts of the gas hob or other hot parts. 7.3 Nozzle replacement Fig. 8 See table on Page 10 for details of nozzle settings. Changing over to a different gas type Only authorised specialists are permitted to change over to a different gas type. The nozzles needed for the gas type to be set are available as a conversion kit. Please specify the appliance type and the required gas type. Nozzles can be replaced without having to open the housing. Loads for all gases For all gas types and pressures, the rated load is achieved by installing the high and low setting nozzles for the required gas type (see nozzle table). The low setting nozzle is screwed in fully at the works, and so the lowest quantity is set. Replacing the low-setting nozzle 1 Proceed as follows: – Disconnect the appliance from the power supply! – Remove the cover from the underside of the appliance under the gas valves. The low-setting nozzle 1 is located in the gas valve and is screwed in from below. (see Fig. 8) – Unscrew the nozzle and insert the new nozzle as specified in the low-setting nozzle table. The nozzle must be screwed in fully. Fit the cover cap again. If it should be necessary to correct the low-setting nozzle 1 as the result of deviating gas types and pressure, the flow rate can be increased by turning to the left. Fig. 9 Fig. 9 See table on Page 10 for details of nozzle settings. Replacing the main nozzle 2 Proceed as follows: – The main nozzle 2 is visible after detaching the burner cover (see Fig. 9). It is unscrewed with a special screw key. – Unscrew the nozzle and insert the new nozzle as specified in the main nozzle table. The nozzle must be screwed in fully and firmly (torque 1.5 Nm) (metallic seal). – Please do not forget to stick the new adhesive label included with the nozzle set over the old adhesive label on the gas connection, thus documenting the changeover to a different gas type. Checking functions Th...
Questo manuale è adatto anche per i modelli :Piani di cottura - VG232222RK/04 (584.33 kb)