Log:
valutazioni - 2, GPA: 5 ( )

Istruzioni per l'uso KitchenAid, Modello 30" and 36" Retractable Downdraft Vent Systems

Produttore : KitchenAid
File Size : 940 kb
File Nome : 30fc1baa-df9a-4347-bc06-8fc866b1954b.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


E 30” and 36” Retractable Downdraft Vent Systems IMPORTANT: Read and save these instructions. IMPORTANT: Installer: Leave Installation Instructions with the homeowner. Homeowner: Keep Installation Instructions for future reference. Save Installation Instructions for local electrical inspector’s use. \ See cooktop Retractable downdraft LUUII I~I UII I I~I Isions manufacturer’s Cutout width: instructions for .vent dimensions 30” vent -2J-112” ,,4” -:-m,n, curour 36” vent cooktop cutout -..1-... -33-112” C5/8” depth and width. 2-518” A = cabinet wall --.. to rear line of cutout \ countertop Allow l/2” from fl rear of downdraft vent to back wall 8-114” of cabinet. retractable vent height Left cabinet ‘, I” wall cutout: II 1J-i/16” Cabinet centerline NOTE: Vent cutout I30” vent base width -27” II I I shown assumes 36” vent base width -33” rear edge of cooktop overlaps Use dimensions edge of downdraft for ductwork vent by 3/W. cutout location that applies to ‘: your installation. 26-118” Locate power supply junction box at lower right corner of cabinet. Allow 112” min. See cooktop Exterior-mounted motor: from rear of manufacturer’s downdraft vent IA b8s.r instructions for to back wall of Interior-mounted motor Cutout CutoutCutout width: width:width: cabinet. cooktop cutout 3@” wnnt 37-4 13” 1 depth and width. 3E C b 9” round hole can be F cut in floor, or right %-l/4” or left side of retractable cabinet. vent height I 9” round hois. Hsioht Use dimensions for 30”;ent base width -27” 9” round hole. location that applies 36” vent base width -33” Height can vary to your installation. as needed. 1-l I I Ii I -------- Locate power supply junction box at lower right corner of cabinet. NOTE: Vent cutout shown assumes rear edge of cooktop 8” overlaps edge of downdraft vent by 318”. cutout 8” dimensions Exterior-mounted motor Figure 1 Figure 2 Dimension A: If just a “Max.” dimension is Example: KECSl 00, 1g-3/8” cutout given, that dimension must be used. “A Max.” 20-518” *If dimension A is between the “Min.” and Actual “A” -19-318” “Max.“: Subtract actual dimension “A” from 1-l/4” + 2 = 518” “A Max.” Divide by 2. C (for A Max.) 9/l 6” Add to “C (for A Max.)” for required + 518” C dimension. l-3116” = Required C dimension Models When installed with Figure ( see ( size ( Gn. ( Mtx. / B / :$L~zo~:.( x ( I I KIRD801 KECSlOP, KGCTlOO’ 2 30” 18-314" 20-5/8" l-314" l-1/2" g/16" 27-l/2" KIRD802 KECT305*, KGCT305* 2” j::‘:‘::.. i~~~~~~~~~ - c‘.‘.:.:.~~~~:i:i:i:i:~ 27-1,2 II KECC500, KECC502, 1 30” ~~~~~~ 20-l p . .....-.i-:.;-,-::. ......... .,...__ y.:.::::.:::.:.:.:.:.:::::::::::’ i:~:~;~~:~:~:~:::::::::::~:::~ -~-~i~-~iis’iiii~~ii KECC507 .:~~:~:~:~~~:~:~:~:~:iiI:I:I::: :::::... . ....__.... . ......... .. KECN507 1 30” 19-l/4" 2-l/8" 27-l/2" KIRD861 KECG260'.KGCG260* 2 36” 18-314" 20-518" l-314" l-112" 9116" 33-l/2" IKIRD862 1KECT365’. KGCT365’ 1 1 1 I I 1 KECN560,‘KECN567 1 36” ~~~~I~I 19-l /4” 2-l/8” 36” v 1 20-l 12” KECC560, KECC567 :~~~~~~~~~~~ Panel A Before you start... Important: Observe all governing codes and ordinances. Proper installation is your responsibility. Make sure you have everything necessary for correct installation. It is the responsibility of the installer to comply with the installation clearances specified on the model/serial rating plate. The model/serial rating plate is located on the front of the downdraft vent above the wiring box cover. Check location where downdraft vent will be installed. The location should be away from strong draft areas, such as windows, doors and strong heating vents or fans. Before making countertop cutout, check that downdraft vent and cooktop location will clear cabinet walls, backsplash, and rear wall studs inside cabinet. ALL OPENINGS IN THE WALL OR FLOOR WHERE RETRACTABLE DOWNDRAFT VENT IS TO BE INSTALLED MUST BE SEALED. Electrical ground is required. See “Electrical requirements,” Panel B. When installing retractable downdraft vent, the cabinet drawer will need to be removed and the drawer front installed permanently to cabinet. 30” min. base cabinet is required. If cabinet has a drawer, 3-l/2” depth clearance from the countertop to the top of the drawer (or other obstruction in the base cabinet) is required. Note: Downdraft vent is installed directly behind the cooktop. Install downdraft vent first. Downdraft vent is not approved for use in mobile homes. Cabinet construction: Downdraft vent is designed for use in a cabinet with a depth of 24”. The maximum depth of the overhead cabinet is 13”. Overhead cabinets installed at either side of the downdraft vent must be 18” above the cooking surface. See cook-top Installation Instructions for the minimum distance between the front edge of the countertop and front edge of cooktop. The minimum horizontal distance between the overhead cabinets is the same as the width of the installed downdraft vent. When installing a 36” retractable downdraft vent with three “Create-A-Cook-top” modules, the optional support must be installed ...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie