Istruzioni per l'uso Faber, Modello KPEU722M

Produttore : Faber
File Size : 570.01 kb
File Nome : c133f9fb-5db1-448a-be4e-6fc9c72f82f9.pdf

Lingua di insegnamento: enfr

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


(6.8 m) Recommended standard fittings 3-1/4" x 10" (8.3 cm x 25.4 cm) to 6" (15.2 cm) = 4.5 ft. (1.4 m) 6" (15.2 cm) to 3-1/4" x 10" (8.3 cm x 25.4 cm) = 1 ft. (0.3 m) 3-1/4" x 10" (8.3 cm x 25.4 cm) to 6" (15.2 cm) 90° elbow = 5 ft. (1.5 m) 6" (15.2 cm) to 3-1/4" x 10" (8.3 cm x 25.4 cm) 90° elbow = 5 ft. (1.5 m) 90° elbow = 5 ft. (1.5 m) 45° elbow = 2.3 ft. (0.8 m) 6" wall cap = 0 ft. (0 m) WARNING Installation steps Excessive Weight Hazard Use two or more people to move and install downdraft vent. Failure to do so can result in back or other injury. 1. Put on gloves and safety glasses. Place cardboard or another form of protection on top of a flat surface where you can easily assemble the downdraft vent system. Remove parts packages, downdraft vent and blower box from carton and set on protective surface. Remove all shipping materials, tape and protective film from downdraft vent and blower box. over counter support arm 2. Attach the left side and right side overcounter support brackets to the downdraft. Use 1 screw with each bracket. 3. Attach the left side and right end cap side end caps to the downdraft. Use 1 screw with each end cap. support leg 4. Attach support legs to side of downdraft vent with 2 screws in each leg. Do not tighten screws. 5. Carefully insert downdraft vent into countertop cutout. Two people are recommended to support the weight of the downdraft vent during lifting. Check that downdraft vent is parallel to side of cutout and that mounting brackets overlap level mark 6. Move support legs down against cabinet floor. Place a level against front of downdraft vent base and adjust until downdraft vent is level vertically. Use a pencil to mark the top of each leg on downdraft vent. Then mark location of support leg mounting holes on cabinet floor. Remove downdraft vent from cutout. Drill starter holes at each mounting screw location on cabinet floor. Align top of legs with pencil marks on the face of the downdraft vent. Tighten screws in legs. 7. Determine which direction (down, rear, left, or right) vent will need to run from blower vent when installed in cabinet. Down venting: Downdraft vent is shipped with blower in down venting position so no modification is required. Go to Step 8. Left or right venting: a. Remove 4 hex nuts that attach blower box to downdraft vent base. Remove blower box. b. Rotate blower box 90° to left or right so that vent blower is repositioned in the direction needed. c. Reattach blower box to downdraft vent base with 4 hex nuts. Rear venting: a. Remove 4 hex nuts that attach blower box to downdraft vent base. Remove blower box. b. Note how wiring cable is installed under plastic clips inside vent base. Then carefully remove wiring cable from plastic clips. Disconnect blower wiring cable. c. Remove 6 Phillips-head screws attaching blower to blower box. Remove blower. countertop. bracket for rear venting d. Remove screws attaching brackets to each side of blower. Reposition brackets on blower as shown. Then reinstall screws. e. Reinstall blower in blower box with mouth of blower pointing out open side of blower box. Secure blower to blower box with 6 Phillips-head screws. NOTE: Square metal frame attached to mouth of blower must be installed for proper operation. f. Attach metal cover from parts bag over down-venting knockout in blower box. Remove rear knockout cover on back of vent base. g. Reconnect blower wiring cable. Secure wiring cable in 2 black plastic clips inside vent base.The wiring cable must be properly secured in the 2 clips (see step b.) Reattach blower box to downdraft vent base with 4 hex nuts. 8. Attach backdraft damper over blower box knockout with 2 Phillips-head screws. 9. Remove the 2 Phillips-head screws attaching the wiring box cover. Determine which direction (rear or down) electrical connection will need to run from appliance wiring box. Remove rear or bottom knockout and install conduit connector. WARNING Excessive Weight Hazard Use two or more people to move and install downdraft vent. Failure to do so can result in back or other injury. 10. Insert downdraft vent into countertop cutout. Two people are recommended to support the weight of the downdraft vent during lifting. Position downdraft vent so it is centered in cutout and parallel to edge of cutout. Check that downdraft vent is level vertically. Then fasten lower support legs to cabinet floor with screws. When attaching undercounter bracket to underside of countertop, make sure that the screw length will not go through countertop when tightened. 11. Attach one undercounter bracket on front upper right corner of downdraft vent with slot over vent mounting hole and flange against countertop. Attach other bracket to left side of downdraft vent. Carefully drill starter holes through undercounter mounting brackets into underside of countertop. Insert appropriate length screws into holes and tighten brackets to countertop. WARNING Electrical Shock Hazard Disconnect power before servici...

Questo manuale è adatto anche per i modelli :
Fans - KPEU722M (570.01 kb)
Fans - KPEU722M (570.01 kb)
Fans - KPEU722M (570.01 kb)
Fans - KPEU722M (570.01 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie