|
Facilità d'uso
5. Take the backing off the tape. 6. Lay the cover plate against the top cabinet and press firmly into place. 7. Fix the plate through the four holes with the supplied blind rivets. The downdraught extractor must not be used beside a gas unit if air recirculation is chosen for the kitchen. 25 Mounting The unit may be mounted in any type of kitchen worktop with a thickness of 28 to 40 mm. Position It is advisable to position the down- draught extractor immediately next to the hob. If two or more hobs are being used, the downdraught extractor should be positioned between them so that optimum use can be made of its variable extraction direction. 26 Cutting Out When fitting this product: read the instructions on this page. When fitting this unit in conjunction with other units: read the instructions on the following page. For fitting this unit you will need a Phillips screwdriver and the fixing supplied (see fig.). Distance from wall: Min. 150 mm from flammable material Min. 50 mm from non-flammable material. 1. Saw a hole of the specified dimensions in the worktop, see “Technical data, installation dimensions”. 2. Insert the unit in the hole and use the fixing supplied in the slot that is the best fit for the kitchen worktop or the thickness involved. Secure the fixing with a manual screwdriver. 27 28 Mounting more than one hob Cutting out The measurement of the selected combination is calculated in the following way: Depth: 490 mm Width: 1. Calculate the sum of all units’ width. 2. Subtract 20 mm from the total width. Example: A hob of 720 mm + a downdraught of 180 mm + a gas hob of 360 mm. 1. 720+180+360= 1260 mm 2. Width of the hole: 1260-20=1240 mm Distance to Wall: Min. 150 mm to flammable material. Min. 50 mm to non-flammable material 490 mm Reinforcement beam Distance to wall: Min. 50 mm (non-flammable material) Distance to wall: Min. 150 mm (flammable material) 29 Mounting: When mounting several hobs together you must use a reinforcement beam between each hob as well as the silicone supplied with the hobs (see fig.) 1. Cut a hole of the calculated size in the table top 2. Place the individual hobs upside down on a mat. Take care that the top side is not scratched. 3. Mount the clamping fittings in the holes in the side of the base panels (see fig.) 4. Place the first hob in the hole. 5. Apply silicone to the two corners joining the next hob (see fig.) Use only the silicone supplied with the hobs as this is intended to tolerate the high temperatures of the appliance. 6. Push a reinforcement beam up against the hob. Apply silicone on the reinforcement beam (see fig.) 7. Tighten the clamping fittings to the table top using a screwdriver. 8. Repeat the process for the other hobs. Silikonet Overview of the outside width of the units 180 mm Downdraught 360 mm Glass ceramic hob with 2 cooking zones Gas hob with 2 burners Induction hob with 2 cooking zones Grill Grill / Fryer Wok 580 mm Glass ceramic hob with 4 cooking zones Gas hob with 4 burners 720 mm Glass ceramic hob with 4 cooking zones Gas hob with 4 burners Induction hob with 4 cooking zones What to do if... If the appliance is not working correctly, please carry out the following checks before contacting your local AEG Service Force Centre. IMPORTANT: If you call out an engineer to a fault caused by incorrect use or installation, a charge will be made even if the appliance is under guarantee. Problems Remedy The downdraught extractor doesn’t work............. The fuses are constantly blowing.. There was a power cut while the extractor was in use. Extraction is off but the extractor is raised. “CL” is visible on the timer display. If the downdraught extractor is obstructed on the way up........... Check whether the extractor is switched on. Check the main fuse has not failed. Check the fuses for the extractor. Possibly, you have too many electrical appliances in use at one time. If the extractor is connected to a 13 Amp fuse group, there is a high risk of overload. Turn the extractor on and press k. Adjust the extractor to the setting you want. The filter cleaning indicator is on. See the section entitled “Cleaning and maintenance of...Filter” for how to clean the filter and reset the indicator. The extractor will switch off automatically and cannot be activated. To activate the extractor, turn the power off and reconnect at the contact or main switch. 31 In-guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mecanicas or electrical brakedown. Please note that it will be necessary to provide ...
Questo manuale è adatto anche per i modelli :Fans - FM 2500DD-A (413.43 kb)
Fans - FM 2500DD-A (413.43 kb)
Fans - FM 2500DD-A (413.43 kb)
Fans - FM 2500DD-A (413.43 kb)