Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso Dimplex, Modello BFH24RB, BFH24RS, BFH24R

Produttore : Dimplex
File Size : 117.61 kb
File Nome : a1fe14db-1f0e-4223-972a-fc7441b70433.pdf

Lingua di insegnamento: en

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


Safety Warnings • DO NOT COVER OR OBSTRUCT the air inlet or outlet grille. • ENSURE THE APPLIANCE IS EARTHED. Do Not place heater immediately below a socket outlet. If the appliance is covered, there is a risk of fire. Do not use this heater with young children unattended. Do not use this heater in areas where excessive dust exists. Do not touch or obstruct the grille areas when the heater is in operation. Introduction This heater has been designed for fitting in the space behind the plinth of floor standing kitchen units or other fitted furniture units. It is recommended that the heater is not installed under cupboards used for storing perishable goods. It can be accommodated in plinths with a minimum height of 12Omm, and is suitable for cupboards of 500mm width and above. Installation The installation of this appliance should be carried out by a competent electrician and be in accordance with the current IEE wiring regulations. Before undertaking installation work, ensure the electricity supply is disconnected from any relevant fixed wiring. The heater is more easily fitted during the installation of new furniture units, or on existing furniture units if they can be temporarily moved from their position against the wall. If an existing furniture unit cannot be moved, then it may be necessary to remove the back of the unit in order to gain access to carry out the wiring installation. Before installing the unit consider the location with respect to the following; The electrical supply and cable length. Position heater to deliver heat effectively without causing personal discomfort from overheating while standing at work surfaces etc. Minimum plinth height of 120mm and minimum furniture unit width of 500mm. Procedure 1. Cutting the aperture in the Plinth Cut aperture in furniture unit plinth to dimensions shown. This must be positioned so that the minimum distance from the bottom of the aperture to the TOP surface of any floor covering is not less than 12mm and not more than 25mm. If an overhang above the heater is greater than 75mm, then a distance of at least 100mm must be maintained between the overhang and the uppermost part of the heater. Note: If fitted in corner with adjacent cupboards to left hand side of heater then a distance of at least 150mm must be maintained between the left hand end of the heater and the front of the adjacent cupboard door. * This dimension must be maintained above the top surface of any floor covering material. All dimensions in millimetres. 2. Power supply connection Check that the supply voltage details on the heater are in accordance with your electricity supply. A 2.5 metre length of inter-connecting cable is supplied. The 6 core inter-connecting cable should be routed from the plinth space to the connection box, ensuring that the cable is left with enough slack to allow removal of the appliance for maintenance. The cable must be protected from any sharp edges. a.) Remote Control Switch Panel Flush or Surface Mounting Conduit/Trunking Two Gang box for Remote Control Switch MK Switches 1. Embedded – Rounded or oval conduit 2. Surface Mounting mini- trunking 3. Surface Mounting – Cable clipped to wall 4. DryLining Box 1. MK 892 ALM (Metal) 2. Marshall Tufflex MSSB 16 (PVC White) 3. MK 2142 WHI (White Moulded) 4. Marshall Tufflex MDLB 2 (Plastic) Determine desired position for remote control switch panel above work bench i.e. 900mm minimum above floor level. It is designed for use with either a surface mounted or flush mounted box as listed in the Table opposite. The left hand column of the Table indicates the type of conduit/trunking required, if any, and the right hand column indicates the corresponding two gang box for the control switch panel. Fix the chosen mounting box in position. b.) Electrical Connection to Remote Control Panel Strip back the outer sheath of the inter-connecting cable by 125mm, at both ends. The conductor sheath should be stripped back by 8mm. Select suitable trunking or conduit from the Table if required. Connect remote control switch panel to the six core inter-connecting cable, in accordance with the wiring diagram. If the 2.5 metre length of cable supplied is insufficient and a substitute cable is used, Ensure that the conductors are of minimum 1.5mm. cross-sectional area. The same size of conductor should be used to link the switch and fuse terminals on the remote control switch panel as indicated in the wiring diagram. c.) Electrical Connection to Appliance Remove the screws securing the top, front and rear covers in order to gain access to the terminal block. Feed the 6 core flexible inter-connecting cable through the cable-clamp at the side of the heater and connect it to the terminal block in accordance with the wiring diagram. It may be necessary to remove the terminal block from its fixing while making connections to it. 3. Fitting the Rear Support Bracket The heater is supplied with a rear support bracket. Fit to the back of the applianc...

Questo manuale è adatto anche per i modelli :
Fans - BFH24R (117.61 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie