Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric shock or injury to persons, always use a licensed electrician. contempraef INSTALLATION 1. Make sure the unit is switched OFF (refer to operating instruction section). 2. Plug the unit into a 15Amp/120volt outlet. If the cord does not reach, you may use an extension cord rated for a minimum of 1875 watts. OPERATION To access the controls go to the front panel of the unit (refer to diagram below) 1. Three position ON/OFF switch The switch has two ON positions marked with “-“ and “=”. The “-“ position is for manual operation. In this position the built-in remote control is bypassed. The “=” position is for operating the unit with the provided remote control. When in “=” position the unit is operated with the ON and OFF buttons of the remote control. When the switch is in the center position the unit is off. 2. HEATER ON/OFF SWITCH The HEATER ON/OFF SWITCH supplies power to the heater fan and the heater element and must be turned on before heat can be created. 3. HEATER THERMOSTAT CONTROL To adjust the temperature to your individual requirements, turn the heater thermostat control knob clockwise all the way to turn on the heater. When the room reached the desired temperature, turn the thermostat knob counter clockwise until you hear a click. Leave in this position to maintain the room temperature at this setting. For additional heat, turn clockwise until you hear the click again and the heater will turn on. To turn the heater off, switch the HEATER ON/OFF SWITCH to the OFF position. NOTE:- When the heater is switched ON, the heater fan will operate. The heater element may or may not be on, depending on the thermostat control setting (SEE “HEATER THERMOSTAT CONTROL” above). 3 REMOTE CONTROL The fireplace is supplied with an integrated on/off remote control. Note: Ensure that the fireplace 3 position switch is set to the remote control setting. To operate, push the ON button to turn fireplace on, push the OFF button to turn the fireplace off. BATTERY REPLACEMENT To replace the battery, slide battery cover open on the hand held transmitter. Correctly install one 12 volt (A23) battery in the battery holder. Close the batter cover. RESETTING THE TEMPERATURE CUTOFF SWITCH This unit is equipped with a thermostat which controls the temperature of the room. It does this by turning the heater on and off. The heater is protected with a safety device to prevent overheating. Should the heater overheat, an automatic cut out will turn the heater off and it will not come back on without being reset. It can be reset by switching the ON/OFF SWITCH to OFF and waiting 5 minutes before switching the unit back on. CAUTION If you need to continuously reset the heater, unplug the unit and call Dimplex North America Limited at 1-800-668-6663. MAINTENANCE WARNING Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire, electric shock or damage to persons. LIGHT BULB REPLACEMENT Allow at least 5 minutes for light bulbs to cool off before touching bulbs to avoid accidental burning of skin. Light bulbs need to be replaced when you notice a dark section of the flame or when the clarity and detail of the log exterior disappears. There are two bulbs under the log set which generate the flames and embers. GLASS CLEANING The glass is cleaned in the factory during the assembly operation. During shipment, installation, handling, etc., the glass surface may collect dust particles, these can be removed by buffing lightly with a clean dry cloth. To remove fingerprints or other marks, the glass can be cleaned with a damp cloth using a good quality household glass cleaner. The glass should be completely dried with a lint free BATTERY COVER BATTERY 4 ON BUTTON OFF BUTTON cloth or paper towel. Do not use abrasive cleaners on glass surface or spray liquids directly onto any surface. contempraef SURFACE CLEANING Use warm water only to clean painted surfaces of the contempraef. Do not use abrasive cleaners on surface or spray liquids directly onto any surface. TO REPLACE THE LIGHT BULBS 1. On the back of the contempraef remove the screws from the light access cover. 2. Remove the light access cover. 4. Reach into the opening, locate and examine the bulbs to determine which bulb(s) required replacement. 5. Unscrew the bulb(s) counter clockwise. 6. Insert new bulb(s). 7. Install the light access cover and install the screws HELPFUL HINTS It is a good idea to replace all light bulbs at one time if they are close to the end of their rated life. Group replacement will reduce the number of times you need to open the unit to replace light bulbs. BULB REQUIREMENTS Quantity of 2 clear chandelier or candelabra bulbs with an E-12 (small) socket base, 60 watt rating. Example GE 60BC of Philips 60 CTC. ONE YEAR LIMITED WARRANTY Products to which this limited warranty applies This limited warranty applies to the following models of your newly ...