OSHA and AGGIH have adopted a current maximum concentration for these materials of 5 milligrams per cubic meter of air. EPA has adopted similar limitations for concentrations of these materials in sewer disposal, but the limitation for a particular disposer is set based on the total allowable for his district or water shed area. Using a closed loop cleaning system, with “oil” wash reduces disposal issues, thus lowering customers disposal costs and helps prevent environmental issues with the EPA and other local agencies. (2) Reclamation of Machine Tool Fluids - customers can reclaim and reuse expensive machine tool fluids, thus providing a tangible ROI on our equipment. (3) Fewer Agency Approvals - closed loop systems require fewer agency permits to operate. (4) No competition - currently, there are no competitors offering a closed loop system. (1) Only Air Boss models 12, 22 and 73 series are approved for use with a closed loop cleaning system. The cabinet seams are continuously welded. (2) Stand off, ceramic insulator or Venturi type insulators are required. (3) Inertia impingers must be used as the pre-filters. (4) Quenchall 100 with Exxon cleaner additive is the only approved wash medium. (5) Minimum pressure at the manifold header must be 50 PSI. (6) Wash tank reservoir must be in accordance with Trion design part number 448226 (attached). Tanks being supplied by others must be reviewed and approved by Trion for adequate capacity, pump, filtration device, means of sludge removal, solenoid valve and pipe size. (7) Oil tank reservoirs must be equipped with an adequate oil heating device. The oil must be heated to at least 140° F prior to starting the wash cycle. (8) The wash frequency shall be once a day, not once a week, or once a month, no exception without a written release of warranty liability from end user. The wash control sequence shall be as follows: (a) Wash cycle is activated. (b) Oil temperature must meet 140° F before system shutdown. (c) Power supply and fan are shut down, fan coast time 60 seconds. (d) Quenchall + Exxon cleaner spray time 2 minutes. (e) Soak time 2 minutes. (f) Rinse time 2 minutes. (g) Dry time 10 minutes minimum. (h) Forced dry time 10 minutes. (i) If there is no forced dry time the fan shall be turned on first for a minimum of 5 minutes before power supplies are turned on. (9) Fire suppression system (by others) is recommended to customer as part of quote in writing to customer. If customer decides not to use fire suppression system, customer shall be aware of the risk factor involved and waive Trion from any fire liabilities in writing. (10) The PWM power supply shall be used for all ESP systems offered with close loop oil wash system, including Air Boss/Models12, 22 and 73 series. Furthermore, when multiple PWM power supplies are used for powering their outputs shall be connected to respective tier of cells, i.e., power outputs shall be in parallel and isolated from each other, so that...
Questo manuale è adatto anche per i modelli :Fans - Air Boss 22 Series (276.69 kb)
Fans - 73 Series (276.69 kb)