LOW-PROFILE WALL HOODS DISCHARGE OPTIONS 11/2" (38) 25/8" (60) TO CENTER OF TRANSITION ATO CENTER OF TRANSITION Verticaldischarge. ATO CENTER OF TRANSITION 11/2" (38) 2" (51) TO CENTER OF TRANSITION Horizontaldischarge. 9" (229) 55/8" (143) TO CENTER OF TRANSITION ATO CENTER OF TRANSITION Verticaldischargewithaccessorytransition. Pro Wall Hood Specifications wolfappliance.com/specs Discharge Specifications 24" AND 27" DEEP WALL HOODS The illustration below provides dimensions for vertical discharge for 24" (610) and 27" (686) deep wall hoods. These dimensions are critical for proper installation. Dimension A in the illustration will vary with the width of the hood. Refer to the chart below. An optional horizontal discharge kit is available through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. 24and27DeepWallHoods WIDTH OF HOOD A 30" (762) 143/4" (375) 36" (914) 173/4" (451) 42" (1067)* 203/4" (527) 48" (1219)* 233/4" (603) 54" (1372)* 263/4" (679) 60" (1524)* 293/4" (756) 66" (1676)* 323/4" (832) 9" (229) 55/8" (143) TO CENTER OF TRANSITION ATO CENTER OF TRANSITION 24"and27"deepwallhoods—verticaldischarge. Duct Cover IMPORTANT NOTE: If an optional duct cover is to be used with any pro wall hood, it must be attached before installing the hood. Installing a duct cover will impact all aspects of the hood installation including hood location, ducting, electrical placement and the mounting surface. DUCT COVER INSTALLATION • Remove all screws from the front edge of the back panel on the top of the wall hood. Leave the two screws on the sides, there is a relief in the duct cover for them. • Attach the duct cover from the inside of the hood through the filter opening using the screws provided. • Leave screws partially loose until all screws are installed. Check alignment of the duct cover with the hood and tighten the four corner screws to secure the duct cover. Tighten all remaining screws. • Proceed with installation of the wall hood. DUCT COVER MOUNTING SCREWS Duct cover installation. Pro Wall Hood Installation Install Ductwork To reduce the risk of fire, use only metal ductwork. IMPORTANT NOTE: Pro ventilation hoods must exhaust to the outdoors except when used with the accessory recir- culating kit (30" and 36" wide hoods only). Wolf recommends that the pro wall hood be installed 30" (762) to 36" (914) above the countertop. Consult a qualified HVAC engineer for specific ducting applications. A 10" (254) round duct is recommended for pro ventilation hoods. Use only metal ductwork, do not use flex ducting. Decide where the ductwork will run between the wall hood and the outside. A straight, short duct run will allow the hood to perform most efficiently. Limit the number of elbows and transitions. The duct run should be no longer than 50' (15 m). There is a possibility of noise issues, if a remote blower is used with a short duct run. Pro low-profile wall hoods allow for a horizontal or vertical discharge. When using an in-line or external blower, an optional 10" (254) round transition is available through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. IMPORTANT NOTE: The transition included with the 500 CFM internal blower accommodates 31/4" (83) x 10" (254) ductwork. An optional 31/4" (83) x 10" (254) to 8" (203) round transition is available through your authorized Wolf dealer. Pro 24" (610) and 27" (686) deep wall hoods have a vertical discharge. If a horizontal discharge is necessary, an accessory horizontal discharge kit is required. Refer to installation instructions provided with the kit. Accessory kits are available through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. Always install a roof or wall cap if you are not installing a remote blower. Connect 10" (254) round metal ductwork to the cap and work back towards the hood. Use duct tape to seal joints between ductwork sections. Pro 24" (610) and 27" (686) deep wall hoods have a back- draft damper included in the transition assembly. Local codes may require the use of an additional backdraft damper. Contact your local HVAC professional for specific requirements. In cold weather installations, a backdraft damper is necessary to minimize the backflow of cold air into the room. Local building codes may require the use of make-up air. Consult your local HVAC professional for specific require- ments in your area. Pro Wall Hood Installation wolfappliance.com/specs Install Ductwork LOW-PROFILE WALL HOODS 24" AND 27" DEEP WALL HOODS DUCTWORK INSTALLATION THROUGH ROOF 22" (559) DEPTH OF HOOD 30" (762) TO 36" (914) COUNTERTOP TO BOTTOM OF HOOD 10" (254) HEIGHT OF HOOD 24" (610) OR 27" (686) DEPTH OF HOOD 18" (457) HEIGHT OF HOOD DUCTWORK INSTALLATION THROUGH ROOF 30" (762) TO 36" (914) COUNTERTOP TO BOTTOM OF HOOD NOTE: 10...
Questo manuale è adatto anche per i modelli :Fans - 811504 (485.06 kb)
Fans - Pro Wall (485.06 kb)
Fans - Pro Wall (485.06 kb)