Log:
valutazioni - 3, GPA: 5 ( )

Istruzioni per l'uso NuTone, Modello 671R

Produttore : NuTone
File Size : 280.18 kb
File Nome : 671Rins87597.pdf
Lingua di insegnamento: enfr
Vai a scaricare



Facilità d'uso


1. Insert hanger bars in slots provided in housing. 2. Locate fan housing between joists so that the bottom of the housing is even with the planned finished ceiling. Extend the hanger bars to the joists. 3. Use screws or nails (not provided) to secure hanger bars to ceiling joists. INSTALLING DUCTWORK 1. Refer to Figure 2. Place duct collar over flanges at discharge opening of fan. Secure collar by snapping tabs into slots in flanges. 2. Run 4" round duct from outside to fan’s discharge opening. 3. Connect duct to fan’s duct collar. WIRING All wiring must comply with local codes and unit must be properly grounded. 1. Run 120vAC house wiring (with ground) from wall switch to fan location. 2. Pull wire through access hole and into junction box. 3. Refer to Figure 4. Use approved wire nuts to connect house supply wires to fixture as follows: white to white; black to black. Connect green or bare ground wire to green ground lead. FIGURE 3 FIGURE 2 WIRING KNOCKOUT MOUNTING TAB FLANGES HANGER BARS (SOLD SEPARATELY) COLLIER DE GAINE PREDE COUPES PATTES DE MONTAGE COLLERETTES LES BARRES DE SUSPENSION SONT VENDUES SEPAREMENT JUNCTION BOX BOITER DE RACCORDEMENT STANDARD WALL SWITCH (NOT INCLUDED) 120vAC, 60Hz HOUSE POWER COURANT DOMESTIQUE 120V CA, 60 Hz GREEN GROUND LEAD VIS VERTE DE MISE A LA TERRE SWITCH BOX BOITER D’INTERRUPTEUR FIELD GROUNDING WIRE TERRE FIGURE 4 POWER/BLOWER UNIT INSTALLATION 1. Place power/blower unit into housing so that mounting plate’s tabs insert into slots in housing. 2. Press other end of mounting plate down until it is firmly seated over scroll and plug-in receptacles. 3. Secure mounting plate to housing with provided screw. 4. Refer to Figure 5. Insert motor plug into junction box receptacle. GRILLE INSTALLATION 1. Refer to Figure 6. Squeezing grille’s mounting springs together, insert springs into slots on both sides of the housing. 2. Press grille firmly into place against ceiling. INSTALLATION IN EXISTING CONSTRUCTION FIGURE 6 SLOTS GRILLEMOUNTING SPRINGS FENTES LA GRILLE RESSORT DE MONTAGE Note: Installation in a finished house requires at least a small accessible area (attic or crawl space) above the planned installation location. 1. After determining desired location for fan, drill a small hole in the ceiling. Place a coat hanger or other stiff wire up through hole to help in locating from above. 2. Place fan housing on top of ceiling surface and use the housing as a template to mark area to be cut out. 3. After cutting out opening, mount housing in the opening using the hanger bars (sold separately), or mount directly to joist using mounting tabs. A. Insert hanger bars in slots in housing. B. Position housing in opening so that bottom of housing is flush with ceiling. C. Use screws or nails (not provided) to secure hanger bars to ceiling joists. D. Complete installation as described above. FIGURE 5 INSERT TABS INTO SLOTS LES INSERER PATTES LES FENTES One Year Limited WarrantyWARRANTY OWNER: NuTone warrants to the original consumerpurchaser of its products that such products will be free from defects inmaterials or workmanship for a period of one (1)year from the date oforiginal purchase. THEREARENOOTHERWARRANTIES, EXPRESSORIMPLIED, INCLUDING, BUTNOTLIMITEDTO, IMPLIEDWARRANTIESOFMERCHANTABILITYORFITNESSFORAPARTICULARPURPOSE. During this one year period,NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective undernormal use and service. THISWARRANTYDOESNOTEXTENDTOFLUORESCENTLAMPSTARTERSORTUBES, FILTERS, DUCT, ROOFCAPS, WALLCAPSANDOTHERACCESSORIESFORDUCTING. This warranty does not cover (a)normal maintenance andservice or (b)any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than byNuTone), faulty installation or installation contrary to recommendedinstallation instructions. The duration of any implied warranty is limited to the one year period asspecified for the express warranty. Some states do not allow limitation onhow long an implied warranty lasts, so the above limitation may not applyto you. NUTONE’SOBLIGATIONTOREPAIRORREPLACE, ATNUTONE’SOPTION, SHALLBETHEPURCHASER’SSOLEANDEXCLUSIVEREMEDYUNDERTHISWARRANTY. NUTONESHALLNOTBELIABLEFORINCIDENTAL, CONSEQUENTIALORSPECIALDAMAGESARISINGOUTOFORINCONNECTIONWITHPRODUCTUSEORPERFORMANCE.Some states do not allow the exclusion orlimitation of incidental or consequential damages, so the above limitationor exclusion may not apply to you. This warranty gives you specific legalrights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. WARRANTYSERVICE: To qualify for warranty service, you must (a)notify NuTone at the address stated below or telephone 1/800-543-8687, (b)give the model number and part identificationand (c)describe the nature of any defect in the product or part. At the time of requesting warranty service, you must presentevidence of the original ...

Questo manuale è adatto anche per i modelli :
Fans - 672R (280.18 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie