|
Facilità d'uso
x 10. rectangular duct—optional for JV338, JV347 and JV367 models Remove the exhaust adaptor from the inside of the hood. Set it aside along with its mounting screws. 31.4 x 10 rectangular exhaust adaptor and screws 2 REMOVE FILTER Remove the shipping tape holding the metal grease filter in place. Pull down on the center of the front edge of the filter. The filter will then slip out of the retaining tabs on the back. 3 Metal grease filter REVERSE THE BAFFLE FOR DUCTED INSTALLATIONS ONLY (JV347 and JV367 models) If the hood is to be recirculated, skip to the next step. Remove the baffle from the top of the hood. Re-install the baffle so the short side marked “VENTED” is visible. The long side of the baffle should be inside the hood. 4 “VENTED” is visible 5 REMOVE WIRING COVER Remove the wiring cover from inside the hood. Set the cover and its mounting screw aside. Wiring cover 6 REMOVE WIRING KNOCKOUT Remove either the top or the back wiring knockout as needed and install an approved strain relief clamp. Strain relief clamp Back knockoutTop knockout Strain relief clamp 7 REMOVE DUCT KNOCKOUT If recirculating, non-vented ductless (JN327 and RN328, and optional for JV347 and JV367 models only), skip to Step 10 D and proceed. Using a flat blade screwdriver, remove the appropriate duct knockout from the top or back of the hood. 31.4. x 10. Rectangular 7. Round vertical vertical discharge. discharge. Remove circular Remove top rectangular duct knockout only. duct knockout only. 31.4. x 10. Rectangular horizontal discharge. Remove rear rectangular duct knockout only. 10 Installation Instructions 10 FOR RECESSED-BOTTOM CABINETS ONLY ANGULAR over the appropriate depending on installation) with two exhaust adaptor top/back Tape Top/back edge Pivot (depending on installation) 8 NOTE: The exhaust adaptor/damper can be installed up to 1 inch on either side of the hood center to accommodate off-center ductwork. In extreme off- center installations, one end of the duct connector may need to be trimmed to clear the electrical cable clamp. Exhaust adaptor/damper (horizontal discharge position) FOR 7. ROUND VERTICAL DUCTED DISCHARGE INSTALLATIONS ONLY: Bend up the duct alignment ears in preparation for later attachment of the 7. duct. 9 Attachment ear tabs Wood shims (minimum thickness 3/8.) • If the cabinets have front, side or back trim, make 2 wood shims a minimum of 3/8. thick and cut to fit the width of the inner recessed cabinet bottom. Attach them to the cabinet bottom recess on both sides. See Step 11 for marking locations. 11 Installation Instructions 11 MARK HOLES C. Outside rear exhaust Select the vent option that your installation will (Horizontal duct–31.4. x 10. Rectangular) require and proceed to that section: • Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, A.Outside top exhaust electrical wiring and keyhole screw slots. (Vertical duct–31.4. x 10. Rectangular) • Use the diagram or the hood as a template and Wood shims mark the locations on the cabinet for ductwork, (recessed-bottom cabinets only–shims must be a minimum of 3/8. thick and cut to fit the width electrical wiring and keyhole screw slots. of the inner recessed cabinet bottom) Hood mounting screws (4) Cabinet front 1.2. 11 .4. 133.4. (30. hood) 133.4. (30. hood) 163.4. (36. hood) 163.4. (36. hood) Cabinet front Horizontal duct 33.4. access hole Cabinet 73.4. 51.4. 51.4. bottom Cabinet Bottom 73.4. 51.4. 133.4. (30. hood) Vertical duct 133.4. (30. hood) 51.4. 95.8. 11.4. 163.4. (36. hood) 163.4. (36. hood) access hole 1.2. 33.4. Electrical access hole 13.8. Hood mounting screws (4) Center line (in wall) Electrical access hole Wood shims (in cabinet bottom) Center (recessed-bottom cabinets only–shims must be a line D.Recirculating (non-vented ductless– minimum of 3/8. thick JN327 and RN328, and optional on and cut to fit the width JV347 and JV367 models only) of the inner recessed cabinet bottom) • Use the hood as a template and mark the locations on the cabinet for the electrical wiring and keyhole screw slots. B.Outside top exhaust (Vertical duct–7. Round) • Since the hood is to be recirculated (not to be vented • Use the diagram or the hood as a template and outside), do not cut out any vent openings in the wall mark the locations on the cabinet for ductwork, or cabinet bottom. electrical wiring and keyhole screw slots. Hood mounting screws (4) 12 CUT HOLES 133.4. (30. hood) 133.4. (30. hood) Cut holes at marked locations for duct and electrical 163.4. (36. hood) 163.4. (36. hood) Cabinet front wiring. For the vertical duct, cut out 3/4. extra toward the front of the cabinet so you can move the duct freely when installing the hood. It may also ease Cabinet 73.4. bottom installation by cutting the hole 101.2. instead of 10.. 8. DIA. 95.8. Access 11.4. HOLE hole for 7. 53.4. round duct 13.8. Electrical access Wood shims Center hole (in cabinet bottom) (recessed-bottom cabinets line only–shims must be a m...
Questo manuale è adatto anche per i modelli :Fans - JV347 (320.65 kb)
Fans - RN328 (320.65 kb)
Fans - JV367 (320.65 kb)
Fans - JV338 (320.65 kb)