Log:
valutazioni - 3, GPA: 4.3 ( )

Istruzioni per l'uso GE Monogram, Modello STAINLESS STEEL PROFESSIONAL HOOD ZV30RSFSS

Produttore : GE Monogram
File Size : 225.82 kb
File Nome : 66d380a2-5940-75a4-3192-643f29e5889b.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


R Listed by Underwriters Laboratories 12" 22-1/2" 29-15/16" 29-15/16" 25" Each hood is shipped with a stainless steel backguard and a warming shelf. Hoods may be installed with the shelf or backguard alone, or with both as shown. Installation Clearances These vent hoods are designed to be installed onto a wall or beneath a soffit or cabinet. Installation with Warming Shelf • Hoods must be installed 32" Min., 38" Max. over any type cooking surface when warming shelf is used. Installation without Warming Shelf • Install these hoods 30" Min. to 36" Max. above the cooking surface when installed over any professional style cooktop or range. • These hoods may be installed 24" min. above a gas or electric drop-in style cooktop. Note: Clearances may vary due to type of cooking product and local codes. Check with local inspectors to be sure standard is applicable. Soffit Installation Warming Shelf Backguard SOFFIT SOFFIT 32" Min. 38" Max. 30" Min. 36" Max. Install these hoods 30" Min. to 36" Max. over a professional style cooktop or range. Allow 32" Min. and 38" Max. clearance above any cooking surface when installed with shelf. In this installation the ductwork running from the top of the hood will be concealed in the soffit or upper cabinetry. Wall Mount Installation SOFFIT SOFFIT 32" Min. 38" Max. 30" Min. 36" Max. Install these hoods 30" Min. to 36" Max. over a professional style cooktop or range. Allow 32" Min. and 38" Max. clearance above any cooking surface when installed with shelf. For this installation, a decorative duct cover is available to conceal the ductwork running from the top of the hood. Use of the duct cover requires special consideration to the installation height above the countertop. ZV30RSFSS – GE Monogram 30" Stainless Steel Professional Hood Advanced Planning Ductwork Planning • These vent hoods are equipped for 10" round ductwork. In most instances they may be transitioned to 8" round. • This hood may be vented vertically through upper cabinets, soffit or ceiling. A duct transition piece is supplied for vertical exhaust. Use locally supplied elbows to vent horizontally through the rear wall. • Determine the exact location of the vent hood. • Plan the route for venting exhaust to the outdoors. • Use the shortest and straightest duct route possible. For satisfactory performance, duct run should not exceed 150 ft. equivalent length for any duct configurations. • Refer to “Duct Fittings” chart to compute the maximum permissible length for duct runs to the outdoors. • Use metal ductwork only. • Install a wall cap or roof cap with damper at the exterior opening. Order the wall or roof cap and any transition needed in advance. Wall Framing for Adequate Support • These vent hoods are heavy. Adequate structural support must be provided. Hoods must be secured to vertical studs in the wall. • It is strongly recommended that the vent hood with duct cover be on site before final framing and wall finishing. This will also help to accurately locate the ductwork and electrical service. Decorative Duct Covers: Decorative duct covers, 6" and 12" high, are available to fit all models. The duct cover conceals the ductwork running from the top of the hood to the ceiling or soffit. Stack one or more duct covers over the top of the hood to reach your ceiling height. Optional Duct Cover Accessories 6" Duct Cover 12" Duct Cover Decorative duct covers are available in 6" and 12" heights. Duct covers may be stacked, in various combinations, to conceal the ductwork running from the top of the hood to the ceiling. • Before you begin, you should determine the installation height of the hood and order the correct size duct cover. The duct covers should be ordered at the same time as the vent hood and be on site before installation. Order the duct cover corresponding to your model. Specification Created 10/02 POWER SUPPLY IMPORTANT – (Please read carefully) WARNING: FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED. Remove house fuse or open circuit breaker before beginning installation. Do not use an extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances. Electric supply These vent hoods must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse. • Wiring must be 2 wire with ground. • If the electrical supply does not meet the above requirements, call a licensed electrician before proceeding. • Route house wiring as close to the installation location as possible on the back wall or ceiling. • Connect the wiring to the house wiring in accordance with local codes. Grounding instructions The grounding conductor must be connected to a ground metal, permanent wiring system, or an equipment-grounded terminal or lead on the hood. WARNING: The improper connection of the equipment-grounding conductor can result in a risk of electric shock. C...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie