Log:
valutazioni - 3, GPA: 4 ( )

Istruzioni per l'uso Field Controls, Modello TYPE "C"

Produttore : Field Controls
File Size : 946.97 kb
File Nome : 04052900.pdf
Lingua di insegnamento: enesfr
Vai a scaricare



Facilità d'uso


The Type “C” Draft Inducer is installed on the top of the vent system outside of the building. English .......Page 1 Francais .....Page 4 Espanol ......Page 6 Page 2 INSTALLATION SMOKE PIPE, TYPE “B” VENTS AND TYPE ”L” VENTS 1. Insert the Type “C” housing directly into the vent pipe. (See Figure 1) 2. Fasten housing to vent pipe using three (3) sheet metal screws, located 120. apart. 3. Seal joint with a high temperature silicone adhesive sealant MASONRY CHIMNEYS 1. Measure the size of the chimney liner and compare this dimension to the diameter of the base plate on the inducer. Allow for at least . inch overlap of the base plate. If this overlap cannot be maintained, refer to Installation with Chimney Cap Section. 2. Apply a bead of high temperature silicone adhesive sealant around the edge of the masonry top or chimney liner. 3. Install the draft inducer on top of the chimney with the unit resting on the base plate. Make sure the unit is sealed. Fasten the inducer to the chimney using anchor bolts and securing wires or cables. (See Figure 2) WITH CHIMNEY CAP 1. Construct a chimney cap that completely covers the outside of the chimney. (See Figure 3) 2. Apply a bead of high temperature silicone adhesive sealant around the hole cut in the center of chimney cap. Fasten chimney cap onto draft inducer base plate with three (3) sheet metal screws. 3. Apply a bead of high temperature silicone adhesive sealant around edge of the masonry top and fasten chimney cap onto chimney. (See Figure 4) Figure 1 Figure 2 Figure 3 Figure 4 Page 3 WIRING 1. Remove the four (4) screws that hold the conical rain cover in place.This will expose the motor juction box. CAUTION: Disconnect electrical power when wiring draft inducer. 2. Wire the draft inducer in accordance with the National Electrical Code and applicable local codes. UNIT MUST BE GROUNDED! Check ground circuit to make certain the unit has been properly grounded. The wiring should be protected by an overcurrent protection circuit, such as a fuse or circuit breaker rated at 15 amperes. (See Diagram A) 3. After wiring, replace conical rain cover. Diagram A Page 4 INDUCTEUR DE TIRAGE DE TETE DE CHEMINEE Model: Type “C” INSTALLATION TUYAUX DE CHEMINEE, EVENTS DE TYPE"B" ET EVENTS DE TYPE "L" 1. Inserer le boitier de type "C" directement dans le tuyau de ventilation. (Voir Le Schema 1) 2. Fixer le boitier au tuyau de ventilation au moyen de trois vis a tole, a 120° de distance. 3. Sceller le joint au moyen d’un adhesif de silicone a haute temperature. CHEMINEES DE MACONNERIE 1. Mesurer la doublure de cheminee et comparer ses dimensions au diametre de la plaque de base de l’inducteur. Prevoir un chevauchement d’au moins . po sur la plaque de base. Si ce chevauchement est impossible, se reporter a la section Installation avec chapiteau de cheminee. 2. Appliquer un cordon d’adhesif de silicone a haute temperature au bord de la cheminee de maconnerie, dans le haut, ou au bord de la doublure de cheminee. 3. Installer l’inducteur de tirage dans le haut de la cheminee, en s’assurant que l’unite repose bien contre la plaque de base. S’assurer que l’unite est scellee. Fixer l’inducteur a la cheminee au moyen de boulons d’ancrage et de fils ou de cables de fixation. (Voir Le Schema 2) AVEC CHAPITEAU DE CHEMINEE 1. Construire un chapiteau de cheminee qui couvre entierement l’exterieur de la cheminee. (Voir Le Schema 3) 2. Appliquer un cordon d’adhesif de silicone a haute temperature autour du trou coupe au centre du chapiteau de cheminee. Fixer le chapiteau a la plaque de base de l’inducteur de tirage au moyen de trois vis a tole. 3. Appliquer un cordon d’adhesif de silicone a haute temperature au bord de la cheminee de maconnerie, dans le haut, et fixer le chapiteau a la c...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie