6. Connect the black wire of the power supply line to the brass screw (polarized) of the socket assembly. 7. Refit the socket assembly back into the electrical box and replace the cover plate. 8. The EB-1 electrical junction box is now ready to supply power to the FK12 or FK24 fan kit, if used. Electrical Inlet Hole Gas Inlet Hole EB-1 Electrical box Depend- ing on the specific model, this box may be installed on either side of the appliance. FP1428 Fig. 6 EB-1 attachment. Remote ON/OFF Switch Installation Do not wire the remote ON/OFF wall switch for this gas appliance into a 120V power supply. 1. Thread the wiring through the holes on the end panels of the appliance. Take care not to cut the wire or insulation on metal edges. Route the wire to a conveniently located receptacle box. 2. Attach the wire to the ON/OFF switch and install the switch into the receptacle box. 3. Connect the other ends of the wire to the gas control valve, as shown in Figure 7. Remote ON/OFF Switch Gas TP Control TH Valve TP TH FP1429 Fig. 7 Remote switch wiring diagram for R models. Alternate Switch Location The remote switch can be installed on the front or the side of the access door. Simply mount the switch to the bracket provided and screw the bracket to either side of the frame, lining up the screws with the prepunched holes. (Fig. 8) 10 10006326 11 360DVS Series Direct Vent Fireplaces 10006326 FP1430 Fig. 8 Alternate switch location. Optional Top Vent Application This appliance is shipped as a rear vent unit. If the installation layout requires the unit to be a top vent configuration, the appliance can be converted by following the steps below. When removing and refitting the plates and adapter, be sure the associated gasket is undamaged and refitted as required. 1. Remove the ten (10) screws securing the outer collar adapter to the fireplace body. (Fig. 9) 2. Set the collar aside, complete with the gasket. NOTE: Do not damage the gasket, as the adapter and gasket must be refitted. 3. Remove the insulation material (exposed in Step 2) from the top of the unit. (Fig. 10) This material can be discarded; however, if the unit is converted back to rear-vent, a new piece of insulation material approved by CFM Corporation must be used for this purpose. NOTE: When converting appliance to top vent, ensure the insulation material referred to in step 3 is completely removed. 4. Remove the 4 screws securing the flue cover plate to the top of the intake box and remove the cover and gasket. (Fig. 11) 5. Remove 4 screws securing the flue pipe to back of the intake box and remove pipe and gasket. (Fig. 11) 6. Secure the plate and gasket removed in step 4 over the flue opening in the back of the intake box. Ensure the gasket is in place and undamaged. 7. Install the flue pipe and gasket removed in step 5 over the flue opening in the top of the intake box. 8. Refit the outer collar adapter and gasket to the unit with the round collar on the top. Secure the adapter with the 10 screws removed in step 1. FP1431 top vent remove screws Remove These Screws Remove These Screws Outer Collar Adapter FP1431 Fig. 9 Remove screws from outer collar adapter. FP1432 remove flue cover and pipe Insulation Pad (Must be removed) Flue Pipe FP1432 Fig. 10 Remove flue cover and pipe. FP1433 flue cover plate Flue Cover Plate Flue Pipe FP1433 Fig. 11 Flue pipe removal. 360 DVS Series Direct Vent Fireplaces Electronic Gas Control Valve This appliance may be fitted with a Honeywell ignition module. Installation of the remote ON/OFF starter switch on electronic ignition units (Fig. 12): 1. Thread the wiring through the holes on the side panels of the appliance. Take care not to cut the wire or insulation on metal edges. Route the wire to a conveniently located receptacle box. 2. Attach the wire to the ON/OFF switch and install the switch into the receptacle box. 3. Connect the white wire from the wall switch to the black wire from the transformer, using an approved wire nut. Connect the black wire from the wall switch to the black wire running from the #6 position of the ignition module, also using an approved wire nut. Fig. 12 Honeywell ignition module. General Venting Your fireplace is approved to be vented either through the side wall, or vertically through the roof. • Only CFM Corporation venting components, specifically approved and labeled for this fireplace, may be used. • Venting terminals shall not be recessed into a wall or siding. • Horizontal venting must be installed on a level plane without an inclining or declining slope. There must not be any obstruction such as bushes, PILOT HONEYWELL IGNITION MODULE ORANGE BLUE BLACK WHITE NOVA SIT 822 VALVE HI LO POWER CORD.. W/FEMALE SPADE 120 VAC RTN WHITE GREEN BLACK 120 VAC HOT BLACK YELLOW 24 VAC RET 40VA TRANSFORMER 24 VAC HOT BLACK WHITE WALL SWITCH WHITE OFF 1 2 3 MV MV/VP PV.. GRD 24V SENSE SPARK 24V ORANGE RED GREEN BLACK FP1225 5 6 8 9 garden shed, fencing, deck or utility building within 24” (610mm) from...
Questo manuale è adatto anche per i modelli :Fans - 360DVS3 (1.94 mb)
Fans - 360DVSR (1.94 mb)
Fans - 360DVS2 (1.94 mb)