Log:
valutazioni - 3, GPA: 4.7 ( )

Istruzioni per l'uso Kobe Range Hoods, Modello CH0030SQB (30")

Produttore : Kobe Range Hoods
File Size : 2.02 mb
File Nome : be7589ba-424e-41c1-848c-660b0ea9b2b1.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


What to Do If You Smell Gas • Extinguish any open flame. • Do not try to turn on the lights or any type of appliance. • Open all doors and windows to disperse the gas. If you still smell gas, call the Gas Company and Fire Department right away. CAUTION 1) For general ventilation use only. Do not use to exhaust hazardous or explosive materials and vapors. 2) To reduce the risk of fire, use only metal ductwork. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) to prevent back drafting. 3) Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and code authorities. 4) Activating any switch on may cause ignition or an explosion. 5) Due to the size and weight of this hood, two people installation is recommended. ELECTRICAL SHOCK HAZARD – Can result in serious injury or death. Disconnect appliance from electric power before servicing. If equipped, the fluorescent light bulb contains small amounts of mercury, which must be recycled or disposed of according to Local, State, and Federal Codes. 2 COMPONENTS OF PACKAGE (Must keep all material for returns or refunds) RANGE HOOD BOX KOBE Range Hood – 1 Warranty Registration Card –1 Instructions Manual – 1 Baffle Filter -2 (30”, 36”, 42”) -3 (48”) Stainless Steel Spacer -2 (30”) -2 (36”) -3 (42”) -2 (48”) Oil Tunnel – 1 Ducting Transition – 1 Screw Package for Transition – 1 Hood-Mounting Bracket-2 Screw Package for Hood-Mounting Bracket w/ Rubber Stand –1 DUCT COVER KIT (Sold Separately) Option Of: Model No. CH0030DC-12 for 30” hood KOBE Duct Cover – 1 Screw Package for Duct Cover -1 Model No. CH0036DC-12 for 36” hood KOBE Duct Cover – 1 Screw Package for Duct Cover -1 Model No. CH0042DC-12 for 42” hood KOBE Duct Cover – 1 Screw Package for Duct Cover -1 Model No. CH0048DC-12 for 48” hood KOBE Duct Cover – 1 Screw Package for Duct Cover -1 3/16" X 3/8" (8 pc) . OPTIONAL RECIRCULATING KIT ALSO AVAILABLE. . FOR MORE INFORMATION, PLEASE VISIT OUR WEBSITE WWW.KOBERANGEHOODS.COM OR CONTACT KOBE RANGE HOODS AT (626) 350-1355. 3 INSTALLATION PLEASE READ ENTIRE INSTRUCTION BEFORE PROCEEDING Calculation before Installation To calculate installation, please refer to Table 1. (All calculation in inches.) -FOR UNDER THE CABINET TABLE 1 A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”) C = Height of Counter Top to Hood Bottom (Recommended 27” to 30”) [(A – B) – (D + E)] D = Height of Hood E = Height of the Cabinet -FOR WALL MOUNT (WITH OPTIONAL DUCT COVER) TABLE 2 A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”) C = Height of Counter Top to Hood Bottom (Recommended 27” to 30”) D = Height of Hood E Height of Duct Cover F = Height of the Hood Installation [A – (B+C)] 4 SAFETY WARNING HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF REMOVING ANY PARTS FOR INSTALLING, CLEANING OR SERVICING. NOTE: USING ELECTRICAL SCREWDRIVERS MAY CAUSE DAMAGE TO THE HOOD. Installation Table of Contents UNDER THE CABINET INSTALLATION................................................................................6 Preparation Before Installation................................................................................................6 Hood Installation ........................................................................................................................6 Ductwork Installation.................................................................................................................7 Wiring to Power Supply.............................................................................................................7 Final Assembly ...........................................................................................................................7 STAND ALONE INSTALLATION ...........................................................................................9 Preparation Before Installation................................................................................................9 Hood Preparation Before Installation .....................................................................................9 Hood Installation ........................................................................................................................9 Wiring to Power Supply...........................................................................................................10 Duct Cover Installation............................................................................................................11 Final Assembly .........................................................................................................................11 5 UNDER THE CABINET INSTALLATION Preparation Before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS ...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie