Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso Hunter Fan, Modello 41787-01

Produttore : Hunter Fan
File Size : 4.63 mb
File Nome : 41787.pdf

Lingua di insegnamento: en

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


x4 3/8" Cable Connector * * * NOTE: Strain relief cable connector must be installed. Not Included. A B C Extra Screws x2 H E D L 77864-02 F G H I J K 03242-07-133 96261-01-000 95047-02-000 74508-03-133 95776-01-000 75184-01-133 96258-01/02/03-008 75171-01/02/03-000 x2 Included. Tools Needed. (Not supplied.) Estimated assembly time: 30 to 60 minutes Before Installation NOTE: Remove all packing materials before installation New construction installation Go to Step A1, page 4 Existing construction Go to Existing Construction Installation, page 8 Turn off the power source. 41787-01 1/11/2006 3 A1 D A2 A4 New Construction Installation A6 F A5 Loosen screw securing motor. Remove the motor/blower from the housing. A3 Remove packing material. Remove the pre-loaded screw tip covers. Back out the pre-loaded screw tips until flush with the side of the housing. Remove the wiring cover screw. 41787-01 1/11/2006 4 A8 D A9 B C A7 E A10 D 5/8 1/2 5/8 1/2 A11 OPTION Remove the wiring cover. Pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and secure with the washer. Position the correct depth mark at the bottom edge of the joist–based on the thickness of your sheet rock. Screw pre-loaded screws into joist or framing. Nail the tabs on both sides to joist or framing so that the housing will be flush with the finished ceiling. (Nails are not provided.) 41787-01 1/11/2006 5 A13 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper Ground A14 Main Switch 1 (AC In) *Option Fan & Main Light Together Switch 2 (AC In) *Option A12 D E A15 F A016 D Pull the wires through the strain relief. Tighten the strain relief screws. Connect wires as shown. Connect a 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. 41787-01 1/11/2006 6 A20 0 G D A18 0 D A17 G ON OFF A21 A22 C1 Go to step on page 12 to attach grille. Connect wiring from the motor to the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. A19 H Secure the motor by tightening the 2 screws. Turn on the power source. Test the motor. If the motor does not run, check the plug connection. 41787-01 1/11/2006 7 7.25” 7.75” D B1 D Existing Construction Installation Cut out an opening for the housing. B2 Use the motor housing as a template to mark position. Existing Fan Remove the existing fan and check to make sure the opening is large enough to accommodate the new motor housing (7.25” x 7.75”). Loosen screw securing motor. B3 Remove packing material. Remove the motor/blower from the housing. 41787-01 1/11/2006 8 B4 B5 B9 B C B7 E B6 E B8 D Remove the pre-loaded screw tip covers. Back out the pre-loaded screw tips until flush with the side of the housing. Remove the wiring cover. Remove the wiring cover screw. Pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and secure with the washer. 41787-01 1/11/2006 9 2 1 B12 D B13 B11 D B10 D B14 Move the housing into position above the ceiling. Pull the wires through the strain relief and tighten the strain relief screws. Attach existing ducting to duct connector. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. Fit housing into the opening and secure by tightening the pre-loaded screws into the joist. Note: Install the box flush with the sheetrock (ceiling). Connect the wiring. 41787-01 1/11/2006 10 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper Ground B15 Main Switch 1 (AC In) *Option Fan & Main Light Together Switch 2 (AC In) *Option D E F B16 H B19 Connect wires as shown. D B17 Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. Connect wiring from the motor to the wiring cover plate. 0 G D B18 Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. Secure the motor by tightening the 2 screws. 41787-01 1/11/2006 11 B20 ON OFF B21 B22 C1 Go to step to attach grille. Turn on the power source. Test the motor. If the motor does not run, check the plug connection. Attaching the Grille C2 K L I J C1 Remove the thumbscrews. Remove glass dome. 41787-01 1/11/2006 12 I C3 C4 I Connect wiring harness. Slide light mount over posts. I J C5 C6 Install 2 Max 60 Watt A15 bulbs (Not Included). Attach thumbscrews. WARNING: To reduce the risk of electrical shock, all 3 thumbscrews MUST be properly installed. L C8 K C7 Align glass dome and push up. Screw glass dome into position. 41787-01 1/11/2006 13 Trouble Shooting Problem: Fan does not come on. Solution: • Hunter Fan Bath Ventilators are extrem...

Questo manuale è adatto anche per i modelli :
Fans - 81004 (4.63 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie