Approximately three minutes after the defrost cycle is activated, the timer will signal the damper to return to its original position for a 2.7 minute period. The defrost cycle will repeat until the outside temperature rises above 27°F (-3°C). 5. Thermally Conductive Core The cross flow heat recovery core transfers heat between the two airstreams. The core removes easily for cleaning or service. 6. Controls - Speed Control Easy operation, simply rotate the Perfect Window. ventilator fan speed control to your desired setting. DAMPER DEFROST (MOTOR AND DOOR) CORE INSTRUCTIONS CABINET DEFROST PORT (NON-DUCTED) FILTER CLIPS (2) HEAT EXCHANGE CORE FILTERS (2) H CHANNEL (CORE GUIDE) (4) DRAIN P TRAP DUCTING (4 PORTS) SQUIRREL CAGE FAN MAIN MOTOR DRAIN PANS DRAIN LINE DOOR KEEPER PLATE (2) INSULATED ACCESS DOOR M11705A 69-0994.4 4 HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS Changing Fan Speed The control fan speed is conveniently located on the ventilator. The rotary fan speed control knob can be manually set from the off (standby) position through speeds 1 to 4. Note the fifth speed (high) is accessible only by a remote control. Off/standby mode may be used if intermittent ventilation is desired. In the off/standby position, the ventilator will not function until energized by a remote control, see information below. It is up to the individual homeowner to set their system to a speed which they find comfortable. If you feel your house is stuffy or there is an above average occupancy rate, you may need to increase your ventilation. In most applications a low to medium speed setting is comfortable. POWER CORD 4-SPEED CONTROL WITH STANDBY POSITION RECOMMENDED MAINTENANCE PRODUCT IDENTIFICATION LABEL* *NOTE: THIS INFORMATION IS VERY IMPORTANT WHEN MAKING INQUIRIES ABOUT YOUR ERV. M11704A Connecting a Remote Device Your ventilator comes equipped with a low voltage terminal strip for connection to several optional control devices. PERFECT CLIMATE COMFORT CENTER. CONTROL The Honeywell Perfect Climate Comfort Center. unit controls your ventilator automatically by using the programmed times or manually by pressing the Ventilate key. See the Perfect Climate Comfort Center. users guide (form 69-0891) for complete instructions. 5 69-0994.4 HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS The dehumidistat (connected to your ventilator) is designed to control the operation of the ventilator fan to help keep the humidity level in your home comfortable. If an independent humidifier is installed and set at 30% (a normal indoor winter level) then the dehumidistat (for the ventilator) should be set at least 10% higher, in this case 40%. With the ventilator operating on low speed and no one is home to produce humidity, the humidifier will keep the humidity level to its setpoint. If the humidity levels rise (due to occupant activity) above the 40% level, then the dehumidistat will automatically increase the speed of the ventilator fan to high until the humidity level falls below 40%. TIMER For your convenience, Honeywell provides a timer control that can fit a wide variety of needs, for example, exhaust humid air from the bathroom or kitchen (see the installation guide for selection and part numbers). WALL SWITCH A wall switch can also be used to switch your ventilator fan speed to high. The fan will run at high speed until the wall switch is turned off. When any remote device is activated the ventilator will run at high speed. All remote devices must be in the off position to return the fan to the speed manually selected on the rotary fan speed control knob. Getting the most from your Fresh Air Ventilation System HOW MUCH VENTILATION DO I NEED? During the seasons that your windows and doors are closed (winter and summer if you have air conditioning), the ventilator should operate continuously when the home is occupied, and either continuously or intermittently when not occupied. For most installations, the ventilator will normally be set to operate continuously on low speed with the option of going to high speed as the need arises. For example, if you are entertaining and there is a large number of people present (some may be smoking), the ventilator should be switched to high speed. YOUR VENTILATOR MAY BE SET TO HIGH SPEED BY: 1. selecting the highest speed on the ventilator or 2. if the system includes an optional remote control, switch it to the ON position. NOTE: To set the dehumidistat, refer to the previous section of this booklet. To operate other ...
Questo manuale è adatto anche per i modelli :Fans - PERFECT WINDOW HR150 (233.88 kb)
Fans - PERFECT WINDOW HR200 (233.88 kb)
Fans - PERFECT WINDOW HR200 (233.88 kb)