Log:
valutazioni - 4, GPA: 3.8 ( )

Istruzioni per l'uso Air King, Modello 4C630P/9012P

Produttore : Air King
File Size : 448.53 kb
File Nome : air-king-9012.pdf
Lingua di insegnamento: enes
Vai a scaricare



Facilità d'uso


FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. 10 14 15 25 5 2 8 18 6 7 3 17 16 DESCRIPTION Air King® 12" (30,4 cm) and 16" (40,6 cm) Wall Mounted Oscillating Fans offer rotary knob/pull cord speed control, variable oscillation, a permanent split capacitor motor and OSHA-complying front steel mesh grill with a 6 ft (1,8m) 18/3 cord set. SPECIFICATIONS Motor ..................................120V, 60 Hz (12" 30,4 cm) 120V, 60 Hz (16" 40,6 cm) Blade diameter....................12" ( 30,4 cm) Model 4C630P/9012P 16" (40,6 cm) Model 4C631Q/9016Q Speeds................................3 Control................................Rotary Knob/Pull Cord Air flow distribution............90° Approvals............................ETL Listed. Close mesh Fan Guard meets OSHA requirements. 26 18 24 7 4 19 11 12 20 LISTA DE REPUESTOS Ref. Parte No. for Modelo No. 4C630P/9012P 4C631Q/9016Q Descripcion Cant. 1 2060316 2060316 Placa de Montaje 1 2 2090003 2090003 Tornillo Phillips #8 x 1-1/4" 2 3 02090045A 02090045A Tornillo Phillips Tipo 25 #8 x 3/4" 6 4 02090272 02090272 Pata de Caucho 2 5 2060202 2060202 Placa Tracera para Colgar 1 6 2010554 2010554 Tapa del Interruptor 1 7 2090008 2090008 Tornillo Phillips #8 x 1/2" 2 8 02055047 02055047 Interruptor con Cordon Accionador 1 9 7091854 7091854 Plastico Protector 2 10 2010512P 2010512P Cuerpo 1 11 2090539 2090539 Casquillo del Cordon Accionador 1 12 02090744 02090744 Tire Cuerda 1 13 02035035 02035036 Conjunto de Motor 1 14 02010162B 02010162B Placa de Trinquete 1 15 02090518 02090518 Resorte de Elevacion 1 16 02090521A 02090521A Eje de Elevacion 1 17 02090033 02090033 Tuerca Hexagonal 1 18 02010548A 02010548A Boton Tipo H.C. 2 19 2010131 2010131 Boton del Interruptor (Rotatorio) 1 20 02050009FPB 02050009FPB Cordon Electrico 1 21 2011212 2011200M Rejilla Plastica Trasera 1 22 2010359 2010359 Tuerca de Seguridad 1 23 2010008 2011013 Aspa 1 24 2010058 2010090 Tapa 1 25 02096217 02096214I Rejilla Frontal 1 26 02010381A 02010381A Ornamento 1 MODEL 4C630P/9012P 4C631Q/9016Q SPEED HIGH MED LOW HIGH MED LOW CFM 940 800 700 1510 1380 1190 M3/s 0.44 0.38 0.33 0.71 0.65 0.56 RPM 1470 1320 1100 1411 1280 1110 Amps 0.46 0.37 0.32 0.80 0.57 0.47 Watts 51 44 39 87 70 57 dBA 45 41 36 51 47 42 GENERAL SAFETY INFORMATION When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to person, including the following: 1. Read all instructions before using Fan. 2. Make certain that the power source conforms to the electrical requirements of the Fan. 3. Use this Fan only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electrical shock, or injury to persons. 4. Unplug power cord before installing, servicing, or moving the Fan. WARNING: DO NOT DEPEND UPON THE ON-OFF SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR SERVICING THE FAN. ALWAYS UNPLUG THE POWER CORD. 5. This Fan must NOT be used in potentially dangerous locations such as flammable, explosive, chemical-laden or wet atmospheres. 6. DO NOT use Fan in or near a window. Rain may create an electrical hazard. 7. The power cord is equipped with a three-prong grounded plug that must be inserted into a matching receptacle. Under no circumstances should the grounding prong be cut off the plug. Where a two-prong wall receptacle is encountered, it must be replaced with a properly grounded three-prong receptacle installed in accordance with the National Electrical Code (NEC) and all applicable local codes and ordinances. This work must be done only by a qualified electrician, using copper wire only. WARNING: USE OF A THREE-PRONG TO TWO-PRONG ADAPTER IS NOT RECOMMENDED. IMPROPER CONNECTION MAY CREATE THE RISK OF ELECTRIC SHOCK. USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA. WARNING: This plug is a safety feature. To reduce the risk of fire, electric shock and personal injury, do not remove, replace, repair or tamper with the originally supplied plug. If the Fan does not function properly, it may be due to the safety device incorporated in this plug. 8. Where possible, avoid the use of extension cords. If they must be used, minimize the risk of overheating by ensuring that they are UL listed. Never use a single extension cord to operate more than one Fan. 9. NEVER operate any Fan with a damaged cord or plug or after the Fan malfunctions, has been dropped or damaged in any manner. 10.Do not insert or allow fingers or foreign objects to enter any ventilation or exhaust opening as it may cause an electric shock or fire, or damage the Fan. Do not block or tamper with the Fan in any manner while it is in operation. 11.Always place the Fan on a stable, flat, level surface when operating, to avoid the chance of the Fan overturning. Locate the Power Cord so the Fan or other objects are not resting on it. Do not run Power Cord under carpeting. Do...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie