Log:
valutazioni - 2, GPA: 5 ( )

Istruzioni per l'uso Air King, Modello FHWC3055LSA

Produttore : Air King
File Size : 1.59 mb
File Nome : 316902442en.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


• Keep duct runs as short and straight as possible. • Duct (elbows and transitions) reduce air • Back to back elbow and “S” turns give very poor delivery and are not recommended. • A short straight length of duct at the inlet of the remote blower gives the best delivery. • Transition to duct from the integral blower or remote duct transition as close to the downdraft as is possible. • Use a suitable 6” round duct. • Flexible metal round ducts should only be used when no other duct exists. Limit use to short lengths and do not crush when making corners. Installing the hood 7 Examples of possible ducting or air fig. recirculation fig. Roof pitch with Sidewall cap Recirculator flashing and cap Pipe Collar Pipe Collar Pipe Collar Installing range hood to the wall (Exhaust operation) IMPORTANT This range hood is very heavy. Adequate structure and support must be provided in all types of installations. Install framing for hood support • If drywall is present, mark the screw hole locations. • Cut away enough drywall to expose 2 vertical studs at the holes location indicated by the template. Install two horizontal supports at least 1” x 6” between two wall studs at the bottom and top mounting holes installation location (fig. ). • The horizontal support must be flush with the room side of the studs. Use cleats behind both sides of the support to secure to wall studs. • Reinstall drywall and refinish. IMPORTANT Framing must be capable of supporting 100 lbs. Step 1: • Make sure that no cables or pipes will become damaged (e.g. electric, gas, water; test the areas in question with a cable detector). • Using supplied template (15), mark and drill 8 holes in the wall. Drill the holes according to the measured distances from the diagram (fig. ). • Upper/Lower bracket (3, 4): Insert 4 wall plugs (9) into the 4 drilled holes. • Range hood (1): Installation is depending on wall type: Wall type Required fasteners Wood No wall plugs (9) required Brick/Concrete 4 wall plugs (9) GB 8 GB fig. 2.95” 5.1” 15.67” 0.86” Long screws 1.5” Wood screws 8.3” 5.9” 15.98”-FHWC3055L 23.86”-FHWC3655L Ceiling Wall Dimension A (see table) Desired range hood distance above a 36” high cook top Ceiling height 8 Feet 9 Feet 10 Feet *1 A*2 A*2 A*2 26”*3 27-5/16” 27”*3 28-5/16” 28-5/16” 28”*3 29-5/16” 29-5/16” 29-5/16” 29”*3 30-5/16”*4 30-5/16” 30-5/16” 30”*3 31-5/16”*4 31-5/16” 31-5/16” 31”*3 32-5/16”*4 32-5/16” 32-5/16” 32”*3 33-5/16”*4 33-5/16” 33-5/16” 33” 34-5/16” 34-5/16” 34” 35-5/16” 35-5/16” 35” 36-5/16” 36-5/16” *1: with 10’ xtension chimney kit FHW10X55LS (14) (not supplied). Please call Frigidaire at 1.800.944.9044 to order this kit. *2: “Dimension A” in the chart represents the height from cook top to where the bottom screw mounting holes would be located. *3: Recommended mounting height *4: Recirculation Kit cannot be installed. Step 2: • Install the range hood (1) either with wood screws or long screws, depending on the wall type: Wall type Required screws Wood 4 wood screws...

Questo manuale è adatto anche per i modelli :
Fans - FHWC3655LSA (1.59 mb)
Fans - FHWC3055LSA (1.59 mb)
Fans - FHWC3055LSA (1.59 mb)
Fans - FHWC3055LSA (1.59 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie