Log:
valutazioni - 4, GPA: 4.3 ( )

Istruzioni per l'uso AEG, Modello CHDE 6260

Produttore : AEG
File Size : 358.29 kb
File Nome : b3a46e50-ceb9-4dd1-b181-dae210d6277d.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


• The national standard on fuel-burning systems specifies a maximum depression of 0.04 bar in such rooms. • The air outlet must not be connected to chimney flues or combustion gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed. • The air outlet installation must comply with the regulations laid down by the relevant authorities. • When the unit is used in its extractor version, a sufficiently large ventilation hole must be provided, with dimensions that are approximately the same as the outlet hole. • National and regional building regulations impose a number of restrictions on using hoods and fuel-burning appliances connected to a chimney, such as coal or oil room-heaters and gas fires, in the same room. • Hoods can only be used safely with appliances connected to a chimney if the room and/or flat (air/environment combination) is ventilated from outside using a suitable ventilation hole approximately 500-600 cm2 large to avoid the possibility of a depression being created during operation of the hood. • If you have any doubts, contact the relevant controlling authority or building inspector’s office. • Since the rule for rooms with fuel burning appliances is “outlet hole of the same size as the ventilation hole”, a hole of 500-600 cm2, which is to say a larger hole, could reduce the performance of the extractor hood. • If the hood is used in its filtering function, it will operate simply and safely in the above conditions without the need for any of the aforementioned measures. • When the hood is used in its extractor function, the following rules must be followed to obtain optimal operation: — short and straight outlet hose — keep bends in outlet hose to a minimum — never install the hoses with an acute angle, they must always follow a gentle curve only — keep the hose as large as possible (preferably the same diameter as the outlet hole). • Failure to observe these basic instructions will drastically reduce the performance and increase the noise levels of the extractor hood. Description of the Appliance • The cooker hood is designed to extract unpleasant odours from the kitchen, it will not extract steam. • The hood is supplied as an extractor unit and can also be used in a recirculation mode by fitting one charcoal filter (available from your local Service Force Centre). Extractor version • In this version fumes are extracted to the outside via a hose. • In order to obtain the best performance the hose should have a diameter equal to the outlet hole. Recirculation Version • The air is filtered through a charcoal filter and returned to the kitchen. • You will need an original AEG charcoal filter for the recirculation function. (Available from your local Service Force Centre). • Insert the charcoal filter into the lugs of the frame above using the 2 red lugs E to retain it, press the red lugs inwards, and insert the charcoal filter in the frame. Fig. 1. E EE Fig. 1 Hood Operation • Best results are obtained by using a low speed for normal conditions and high speed when odours are more concentrated. Turn the hood on a few minutes before you start cooking then you will get an underpressure in the kitchen. It should be left on after cooking for about 15 minutes or until all odours have disappeared. The control switches are located on the unit’s front panel: Intensive speed Light switch Motor switch The hood is also equipped with a micro-switch which can be found under the lower runner of the visor on the right hand side. With this micro-switch, the appliance may be automatically switched on and off by opening and closing the pull-out panel, but only if the fan speed has already been set and the light button is turned to “I”. Maintenance and care • The hood must always be disconnected from the electricity supply before beginning any maintenance work. • Never insert pointed objects in the motor’s protective grid. • Wash the outside surfaces using a delicate detergent solution. Never use caustic detergents or abrasive brushes or powders. • Only ever clean the switch panel and filter grille using a damp cloth and delicate detergents. • It is extremely important to clean the unit and change the filters at the recommended intervals. Failure to do so will cause grease deposits to build up that could constitute a fire hazard. ON OFF Metal grease filter • The purpose of the grease filters is to aspirate grease particles which form during cooking and it must always be used, either in the external evacuation or internal recycling function. Attention: the metal grease filters must be removed and washed, either by hand o...

Questo manuale è adatto anche per i modelli :
Fans - DE 6250 (358.29 kb)
Fans - DE 6260 (358.29 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie