|
Facilità d'uso
• Tighten the 4 screws (7). • Insert and tighten another 2 screws in the remaining free holes (8) for secure fixing. • Carry out the electrical connection (9) to the mains power supply, only turn on the power supply upon completion of assembly. • Hook the hood onto the truss (10) , ensuring it fits properly – to hook the hood onto the truss partially tighten 4 screws (see also step 12). • Secure the hood to the truss using two screws (11); this will also help center the two sections. • Tighten the 4 screws securing the truss to the hood (12). • For extractor versions (13A), connect the other end of the exhaust pipe to the flue. For filter versions (13F), fit deflector F to the truss and secure it to the bracket supplied using 4 screws, then connect the exhaust pipe to the connection ring located on the deflector. 90 2a 3 4 4 4 4 4 4 6 6 7 7 7 7 8 8 2a 5 7 9 10 10 10 10 11 11 14,5 273 273 244 214 190 6 12 2b 2b Fig. 6 • Fit the nuts with fixing hooks (14) supplied inside the top and bottom sections of the flues at the rectangular slots. A total of 10 nuts must be fitted. • Join the two top sections of the flue to cover the truss (15) so that one of the slots on the sections is situated on the same side of the control panel and the other on the opposite side. Screw the two sections together with 4 screws (2 each side- see the plan diagram for joining the two sections). • Fix the top flue assembly to the truss, near the ceiling, with two screws (16 - one each side). • Carry out electrical connection of control panel and bulbs (17). • Join the two bottom sections of the flue covering the truss (18) using 6 screws (3 each side, see the plan diagram for joining the two sections). • Insert the bottom section of the flue in its seat so that it completely 92 15 15 15 15 15 16 16 15 15 13F F 13A 15 14 Fig. 7 covers the motor compartment and electrical connection box, then ensure it from inside the hood using two screws (19). • Apply the 2 tabs (20 - supplied) to cover the fixing points of the bottom flue (CAUTION! THE BOTTOM FLUE TABS ARE THE NARROWER AND SHALLOWER ONES). The wider and deeper tabs are those used for the top flue, and must be cut to size. • Turn the mains power on again at the central electrical panel and check for correct hood operation. 94 19 18 18 18 18 18 18 18 18 18 18 M X 17 17 19 20 X 20 Fig. 8 ...
Questo manuale è adatto anche per i modelli :Fans - DI 8610 (2.24 mb)
Fans - DI 8610 (2.24 mb)
Fans - DI 8610 (2.24 mb)
Fans - DI 8610 (2.24 mb)