Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso Carrier, Modello 62MC

Produttore : Carrier
File Size : 2.15 mb
File Nome :

Lingua di insegnamento: en

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


24 — 62MD,ME075,120 Coupled with Carrier 48/50PG03-14 Vertical Discharge Rooftop Unit 23 Accessory Transition ERV Wheel must be watertight) Rooftop Unit Accessory Transition (Includes front panel) 62M Unit Rooftop Unit ERV Curb Locator pieces (included with ERV curb, 62M075-120 ERV Unit LEGEND ERV — Energy Recovery Ventilator NOTE: When using a 62M ERV unit coupled with a Carrier rooftop unit, the rooftop factory or field- installed economizer cannot be used. TOP VIEW ROOF CURB LOCATION DETAIL ERV Curb A B 30 1/12" 27" 2 3/4" 20" Locator pieces (included with ERV Curb) A A Curb Detail Rooftop Unit Curb 20" ERV Unit Curb Side View A-A Rooftop Unit Curb ROOFTOP MODEL ROOFTOP SIZE 62M TRANSITION ERV CURB DIMENSIONS (in.) A B 48/50PG 03-07 62M-ATR-PG26-H 62M-A-CRB-14MC 805/16 4411/16 08-14 62M-ATR-PG712-H 62M-A-CRB-14MC 923/4 5315/16 Fig. 25 — 62MD,ME075,120 Coupled with Carrier 48/50PG03-14 Horizontal Discharge Rooftop Unit 24 Top View Locator Pieces (included with ERV curb, must be watertight) ERV Curb Filter door shipped with Rooftop unit Rooftop curb Rainhoods for optional economizer ERV Wheel SUPPLY RETURN 30” 62M ERV Unit 62M170-285 ERV Unit Accessory Transition Rooftop Unit Rooftop unit Top View Locator Pieces (included with ERV curb, must be watertight) ERV Curb Filter door shipped with Rooftop unit Rooftop curb Rainhoods for optional economizer ERV Wheel SUPPLY RETURN 30” 62M ERV Unit 62M170-285 ERV Unit Accessory Transition Rooftop Unit Rooftop unit 49 5/8" B A 38" 2 3/4" 45 1/2" Locator Pieces ( included with ERV curb) Cover panel provided Rooftop Unit curb ERV curb ROOF CURB LOCATION DETAIL LEGEND ERV — Energy Recovery Ventilator NOTE: When using a 62M ERV unit coupled with a Carrier rooftop unit, the rooftop factory or field-installed economizer cannot be used. Use the 62M economizer instead. Top View ROOFTOP UNIT MODEL ROOFTOP SIZE TRANSITION P/N ERV CURB P/N ROOFTOP ECONOMIZER DIMENSIONS (in.) A B 004-007 62M-BTR-HJ36-D 62M-B-CRB-14MC 62MA-900---004 673/8 373/16 48/50HJ,TF,TJ,TM 008,009 62M-BTR-HJ78-D 62M-B-CRB-14MC 62MA-900---005 781/4 50 012,014 62M-BTR-HJ1012-D 62M-B-CRB-14MC 62MA-900---006 781/4 50 Fig. 26 — 62MD,ME170-285 Coupled with Carrier 48/50HJ,TF,TJ,TM004-014 Vertical Discharge Rooftop Unit 25 Optional Horizontal Economizer Top View ERV Wheel Accessory Transition 62M170-285 ERV Unit Rooftop Unit Horizontal ERV curb, ERV CurbReturn duct must be watertight) (field supplied) Rooftop Unit Filter door shipped with Rooftop unit. 62M ERV Unit Locator pieces (included with B Rooftop Unit curb ROOF CURB LOCATION DETAIL Locator Pieces ( included with ERV Curb) Cover Panel provided A 49 5/8" ERV curb 45 1/2" 2 3/4" 38" Top View LEGEND NOTE: When using a 62M ERV unit coupled with a Carrier rooftop unit, the rooftop factory or field-installed economizer cannot be used. Use the 62M economizer instead. ERV — Energy Recovery Ventilator ROOFTOP UNIT MODEL ROOFTOP SIZE TRANSITION P/N ERV CURB P/N ROOFTOP ECONOMIZER DIMENSIONS (in.) A B 004-007 62M-BTR-HJ36-H 62M-B-CRB-14MC 62MA-900---008 673/8 373/16 48/50HJ,TF,TJ,TM 008,009 62M-BTR-HJ78-H 62M-B-CRB-14MC 62MA-900---009 781/4 50 012,014 62M-BTR-HJ1012-H 62M-B-CRB-14MC 62MA-900---010 781/4 50 Fig. 27 — 62MD,ME170-285 Coupled with Carrier 48/50HJ,TF,TJ,TM004-014 Horizontal Discharge Rooftop Unit 26 Rooftop Unit LEGEND ERV — Energy Recovery Ventilator NOTES: 1. The 62M ERV unit cannot be coupled with horizontal return 48/50TJ,TM016-028 and 48/50HJ015,017 units. 2. The ERV unit can be used with a factory- installed economizer, if desired. TOP VIEW SIDE VIEW 62M ERV unit ERV curb Unit curb Accessory Transition Rooftop Unit ERV Wheel 15 to 25 Ton Rooftop Unit Transition *Optional Economizer Accessory Transition 62M170-285 ERV Unit 62M170-285 ERV Unit ROOF CURB LOCATION DETAIL ERV Unit Curb 67 1/16"* 74 1/4" Rooftop Unit Curb ERV Curb 18 11/16" 49 5/8" 45 1/2" 44 3/4" SUPPLYRETURN44 3/4" Rooftop Unit Curb A A TOP VIEW SIDE VIEW A-A *Length is 891/16 . for 48/50TM028 units. ROOFTOP UNIT MODEL ROOFTOP SIZE TRANSITION P/N ERV CURB P/N 48/50TJ,TM 016-028 62M-BTR-HJ1525-D 62M-B-CRB-14S 48/50HJ 015,017 62M-BTR-HJ1525-D 62M-B-CRB-14S Fig. 28 — 62MD,ME170-285 Coupled with Carrier 48/50TJ,TM016-028 and 48/50HJ015,017 Vertical Discharge Rooftop Unit 27 Supply ERV Wheel TOP VIEW Transition Return Supply ERV Wheel TOP VIEW Transition Return Rooftop Unit Accessory ERV curb, ERV Curb must be watertight) 62M170-285 ERV Unit LEGEND ERV — Energy Recovery Ventilator Accessory Transition (Includes front panel) 62M ERV Unit Rooftop Unit Locator pieces (included with NOTE: When using a 62M ERV unit coupled with a Carrier rooftop unit, the rooftop factory or field-installed economizer cannot be used. ROOF CURB LOCATION DETAIL ERV Curb A B Supply Return 49 5/8" 45 1/2" 38 3/4" Locator pieces (included with ERV Curb) A A Curb Detail Rooftop Unit Curb 38 3/4" ERV Unit Curb Side View A-A 0" Rooftop Unit Curb ROOFTOP MODEL ROOFTOP SIZE 62M TRANSITION ERV CURB DIMENSIONS (in.) A B 48/50P...

Questo manuale è adatto anche per i modelli :
Fans - 62MB (2.15 mb)
Fans - 62MD (2.15 mb)
Fans - 62ME (2.15 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie