Log:
valutazioni - 2, GPA: 4.5 ( )

Istruzioni per l'uso Hotpoint, Modello HD 93 X

Produttore : Hotpoint
File Size : 545.87 kb
File Nome : HD63X_HD73X_HD93X_04307812.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Fixing to the wall 1) Draw a line on the wall along the vertical axis of the hob. Mark the 2 holes (A) to be made in the wall respecting the measurements indicated in the figure below. 2) Drill the holes (8 mm o) and fit the 2 screw anchors (provided). 3) Fix the metal bracket (B) to the wall with 2 screws using the 2 holes drilled. Use the 2 triangles cut into the bracket to position it exactly along the vertical axis of the hood. 4) Then hook the hood onto the metal bracket.Adjust the horizontal position by moving the hood to the right or left as required to align it with the wall units. If the hood also needs to be adjusted in height, operate on the adjusting screws (C). 5) Once adjusted, finally fix the hood with a further 4 screws (D): Mark the 4 holes to be drilled on the wall, unhook the hood and drill the holes marked (8 mm diameter); then use the screw anchors and the screws provided for final fixing. FOR CORRECT FUNCTIONING, THE HOOD MUST BE FIXED USING ALL FOUR SCREWS (D)! 6) For the hoods in filtering version, fit the reducer (E). Securing the decorative flue 1) Assemble the support bracket of the decorative flue and adjust the width with the 2 screws (F). Then, using the screw anchors and the screws (G), secure it to the ceiling in such a way that it is in line with the hood. 2) For the filtering version, the air vent grilles (H) must be positioned at the top. For the ducting version, turn the upper flue upside down so that the air vent grilles are at the bottom. 2 GB d) Make the electrical connection of the hood by means of the power cable (refer to the paragraph 3) Ducting version: “Electrical connection”). e) Lower the lower flue resting it on the hood. a) Connect the air vent of the hood to the air vent f) Check if the charcoal filter (P) has been hole using a flexible hose of 15 cm diameter. installed. If not yet installed, proceed by sliding Lock the flexible hose with hose clamps (hose the 2 filter clips into their seats and turn the and clamps not provided). filter upwards. b) Make the electrical connection of the hood by means of the power cable (refer to the paragraph “Electrical connection”). c) Fit the decorative flue resting it on the hood. Lift the upper flue up to the ceiling and secure it by means of the 2 screws (L). 4) Filtering version: a) Fit the baffle (M) to the upper flue using 4 flat- headed screws (N). Connect a flexible hose of 12.5 cm diameter to the baffle locking it with a hose clamp (hose and clamp not provided). b) Take the decorative flue and rest it on the hood. Lift the upper flue up to the ceilingand secure it using the 2 screws (L). c) Lift the lower flue holding it firm with some adhesive tape and connect the flexible hose to the reducer (E) with a hose clamp (not provided). 3 Technical information GB Electrical connection ! Arrange the electrical power supply within the decorative flue dimensions. ! When making the electrical connections, check that the voltage values correspond to those indicated on the data plate inside the appliance itself. ! In case your appliance is not furnished with a non separating flexible cable and has no plug, or has not got any other device ensuring omnipolar disconnection from the electricity main, with a contact opening distance of at least 3 mm, such separating device ensuring disconnection from the main must be included in the fixed installation. ! If your unit features a power lead and plug, position this so the plug is accessible. ! The following warning is valid in the United Kingdom only (in case your cable is not furnished with a plug). As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: – the wire which is coloured blue must be connected to the terminal Technical data which is marked with the letter N or coloured black; – the wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red. – the wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol [ ], or coloured green or green and yellow. Power cable ! Warning: The hood is fitted with a specially prepared cable; if the cable is damaged, it must be replaced with a cable or special cable assembly, available at the manufacturer or its technical service. Model HD63X HD73X HD93X Dimensions width 59.8 cm height 67.7 / 99.5 cm depth 50 cm Outlet pipe diameter 15 cm width 69.8 cm height 67.7 / 99.5 cm depth 50 cm Outlet pipe diameter 15 cm width 89.8 cm height 67.7 / 99.5 cm depth 50 cm Outlet pipe diameter 15 cm Gross weight 20 Kg 21 Kg 24 Kg Absorption Total 220 W Total 220 W Total 220 W Motor 1x180 W Motor 1x180 W Motor 1x180 W Lamps 2x20 W Lamps 2x20 W Lamps 2x20 W Flow rate 560 m3/h 560 m3/h 560 m3/h Grease filters Suction surface area 944 cm2 944 cm2 944 cm2 4 Description The hood may be in the filtering or ducting v...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie