|
Facilità d'uso
65 x 30 mm 3) Height range for appliance in extraction mode 4) Height range for appliance in recirculation mode 5) Ventilation grille positioned at the top for recirculation Exhaust connection C 150 mm (not needed for recirculation mode) DA 424 V (Ceiling fixing viewed from above) Appliance dimensions Safety distance between hob and cooker hood (S) The minimum safety distances between the top of a cooker or hob and the bottom of the cooker hood are as follows, unless a greater distance is specified by the manufacturer of your cooking appliance: – 550 mm above electric hobs and cookers, – 650 mm above gas hobs and cookers, – 650 mm above an open grill or deep fat fryer. For further advice, see "Warning and Safety". If the distance falls below the recommended safety distance when the canopy is lowered, the max. interval it is allowed to be lowered must be re-set during installation. See the installation instructions for further advice. Installation Assembly parts 4 screws 8 x 60 mm with 4 washers and 4 plugs S 10 to secure the cover plate to the ceiling The screws and plugs are designed for use in concrete ceilings. For other types of construction, alternative suitable fixings will be required. Make sure the ceiling is strong enough to bear the weight of the cooker hood. 2 spring clips to hang the cooker hood onto the cover plate 4 countersunk screws M 6 x 20 mm with locating bar and 4 self-locking nuts M 6 to secure the cooker hood to the cover plate Before installation, it is important to read the information given on the following pages as well as the "Appliance dimensions" and the "Warning and Safety instructions" at the beginning of this booklet. This is particularly crucial when using the cooker hood at the same time as a heating appliance that relies on oxygen from the same room, which could result in the build-up of toxic fumes. Installation instructions See enclosed Installation sheet for instructions on how to install this appliance. Special installation instructions for recirculation mode (DA 420 V only) In order to use the cooker hood in recirculation mode, it has to be fitted with a special conversion kit which is available from the Spare Parts Department (see "Technical data"). It is supplied with its own fitting instructions. After the cooker hood has been installed, the charcoal filter has to be fitted, and the operating hours counter has to be set. 1 cable clip for securing the exhaust ducting to the exhaust stub. Electrical connection All electrical work should be undertaken by a suitably qualified and competent person in strict accordance with current national and local safety regulations (BS 7671 in the UK). Installation, repairs and other work by unqualified persons could be dangerous, for which the manufacturer cannot be held liable. Ensure power is not supplied to the appliance until after installation or repair work has been carried out. Do not connect the appliance to the mains electricity supply by an extension lead. These do not guarantee the required safety of the appliance. The voltage and connected load are given on the data plate. This is visible when the grease filters have been removed. Ensure that these match the household mains supply. Connection of this appliance should be made via a suitable isolator or a double pole fused spur connection unit which complies with national and local safety regulations and the On-Off switch should be easily accessible after the appliance has been built in. When switched off there must be an all-pole contact gap of 3 mm in the switch (including switch, fuses and relays according to EN 60 335). If the switch is not accessible after installation (depending on country), an additional means of disconnection must be provided for all poles. For extra safety it is advisable to install a residual current device (RCD) with a trip current of 30 mA. Important U.K., IRL, NZ, ZA: This appliance is supplied for connection to an a.c. 230 V single phase 50 Hz supply. AUS: This appliance is supplied for connection to an a.c. single phase 240 V, 50 Hz supply. The wires in the mains lead are coloured in accordance with the following code: Green/yellow = earth Blue = neutral Brown = live WARNING: THIS APPLIANCE MUST BE EARTHED Operation with Control module DSM 400 The Miele DSM 400 Control module can be used to combine the cooker hood with other components. It enables the following: Connection to a window contact switch If adequate ventilation to the room can only be ensured by having a window open when the cooker hood is in use at the same time as a heating appliance which depends on the air from the same room, then the control module can be used to connect a window contact switch (not supplied) to the appliance. Once connnected, the cooker hood can only be operated when the window is sufficiently open (see also "Warning and Safety instructions"). When the window is closed the cooker hood fan cannot be switched on. The indicator lamp for the On/Off touch contro...
Questo manuale è adatto anche per i modelli :Fans - DA 420 V (832.63 kb)
Fans - DA 420 V EXT (832.63 kb)
Fans - DA 424 V (832.63 kb)