INPUT 34,500 BTU/HR 30,000 BTU/HR MIN. INPUT 20,000 BTU/HR 20,000 BTU/HR MANIFOLD PRESSURE 3.5” W.C. 10” W.C. M/FOLD PRESSURE LOW 1.0/3.5” W.C. 4.5/10.0” W.C. MIN. INLET PRESSURE 5.0” W.C. 11.0” W.C. MIN. SUPPLY PRESSURE 5.5” W.C. 11” W.C. MAX. SUPPLY PRESSURE 10.5” W.C. 14” W.C. ORIFICE SIZE #34 #51 MINIMUM CLEARANCES TO COMBUSTIBLES England’s Stove Works highly recommends the use of smoke detectors and Carbon Monoxide detectors with any hearth product, including this unit. Follow all manufacturer’s instructions when using smoke or Carbon Monoxide detectors. THIS APPLIANCE SHALL BE INSTALLED ON A METAL OR WOOD PANEL THAT EXTENDS THE FULL WIDTH AND DEPTH OF THE APPLIANCE WHEN INSTALLED ON A COMBUSTIBLE SURFACE OTHER THAN WOOD. WARNING: WHEN USED WITHOUT FRESH AIR THIS HEATER MAY GIVE OFF CARBON MONOXIDE, AN ODORLESS POISONOUS GAS. OPEN A WINDOW AN INCH OR TWO FOR COMBUSTION AIR. WARNING This appliance is equipped for (natural or propane) gas. Field conversion is not permitted. This heater is equipped with a PILOT LIGHT (OXYGEN DEPLETION SENSOR) SAFETY SYSTEM designed to turn off the unit if there is not sufficient fresh air available. If the appliance keeps shutting off, have it serviced. DO NOT TAMPER WITH THE PILOT LIGHT (ODS) SAFETY SYSTEM! Keep the burner and control compartment clean. CARBON MONOXIDE POISONING MAY LEAD TO DEATH Early signs of carbon monoxide poisoning resemble the flu, with headache, dizziness and/or nausea; if you have these signs the heater may not be operating properly. Get fresh air at once! Have the heater serviced by a qualified technician. Some people – pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, or those at high altitudes are more affected by carbon monoxide. THE INSTALLATION MUST CONFORM TO LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, THE CURRENT NATIONAL FUEL GAS CODE – ANSI Z223.1 (NFPA 54). ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING THIS UNIT MUST BE REPLACED PRIOR TO OPERATING THE HEATER. CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE. THIS HEATER SHALL NOT BE INSTALLED IN A CONFINED SPACE UNLESS PROVISIONS ARE PROVIDED FOR ADEQUATE COMBUSTION AND VENTILATION AIR. THE NATIONAL FUEL GAS CODE DEFINES A CONFINED SPACE AS A SPACE WHOSE VOLUME IS LESS THAN 50 CUBIC FEET PER 1,000 BTU PER HOUR (4.8 CUBIC METERS PER KW) OF THE AGGREGATE INPUT RATING OF ALL APPLIANCES INSTALLED IN THAT SPACE. ROOMS COMMUNICATING DIRECTLY WITH THE SPACE IN WHICH THE APPLIANCES ARE INSTALLED THROUGH OPENINGS NOT FURNISHED WITH A DOOR, ARE CONSIDERED A PART OF THE CONFINED SPACE. DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES. DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIAL ON OR NEAR THE APPLIANCE. INSTALLATI...
Questo manuale è adatto anche per i modelli :Fans - 60-TRULP (136.53 kb)
Fans - 26-GUHLP (136.53 kb)
Fans - 26-GUHNG (136.53 kb)
Fans - 26-GULP (136.53 kb)