Log:
valutazioni - 5, GPA: 4.6 ( )

Istruzioni per l'uso Broan, Modello U24211 EFT 535

Produttore : Broan
File Size : 516.87 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


The appliance has not been serviced, maintained, repaired, taken apart or tampered with by any person not authorised by us. All service work under this guarantee must be undertaken by an Electrolux Service Force Centre. Any appliance or defective part replaced shall become the Company’s property. This guarantee is in addition to your statutory and other legal rights. Home visits are made between 8.30am and 5.30pm Monday to Friday. Visits may be available outside these hours in which case a premium will be charged. Exclusions This guarantee does not cover: Damage or calls resulting from transportation, improper use or neglect, the replacement of any light bulbs or removable parts of glass or plastic. Costs incurred for calls to put right an appliance which is improperly installed or calls to appliances outside the European Community (EC) or European Free Trade Area. Appliances found to be in use within a commercial environment, plus those which are subject to rental agreements. Products of Electrolux manufacture which are not marketed by Electrolux. European Guarantee If you should move to another country within Europe then your guarantee moves with you to your new home subject to the following qualifications: The guarantee starts from the date you first purchased your product. The guarantee is for the same period and to the same extent for labour and parts as exists in the new country of use for this brand or range of products. This guarantee relates to you and cannot be transferred to another user. Your new home is within the European Community (EC) or European Free Trade Area. The product is installed and used in accordance with our instructions and is only used domestically, i.e. a normal household. The product is installed taking into account regulations in your new country. Before you move please contact your nearest Customer Care centre, listed below, to give them details of your new home. They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances. France Senlis +33 (0)3 44 62 20 13 Germany Nurnberg +49 (0)800 234 7378 Italy Pordenone +39 (0) 800 117511 Sweden Stockholm +46 (0)20 78 77 50 UK Slough +44 (0) 1753 219898 39 Technical Specifications Model EFT 630 - EFT 635 EFT 530 - EFT 535 EFT 630/GB - EFT 635/GB Dimensions (in cm): Height (cm) 13 13 13 Width (cm) 59,8 49,8 59,8 Depth (cm) 51 51 51 Maximum absorbed power: 160W 160 W 180 W Motor absorption: 1 x 120 W 1 x 120 W 1 x 120 W Lighting: 1 x 40 W 1 x 40 W 2 x 40 W Length of the cable: 150 cm 150 cm 150 cm Electrical connection: 220 - 240 V 220 - 240 V 220 - 240 V Subject to change without notice. Installation Unpacking Check that the cooker hood has no damages. Transportation damages should immediately be reported to the company responsible for the transportation. Damages, faults and eventually missing details should immediately be reported to the retailer. Take care of the packing materials so that small children cannot play with them. Fitting The hood is to be mounted on the wall. When installed, the hood must be not less than 60 cm. above electric burners or 65 cm. above gas or mixed-fuel burners. The hood can be installed above these heights but for optimum performance it should be installed at the distance quoted for the appropriate heat source. Electrical connection (not for UK) Safety warnings for the electrician Before connecting the appliance to the power supply, check that the voltage indicated on the rating plate corresponds to the mains power supply available. Appliances fitted with a plug can be connected to any standard power socket within easy access. Should it be necessary to provide a fixed connection, the hood must only be installed by an electrician authorised by the local electricity board. When installing, a double pole switch with a distance of at least 3 mm between contacts must be provided. Fixed connection of the appliance must only be carried out by an authorised electrician. Min 65 cmMin 60 cm Fig. 7 - Fitting Electrical connection for UK only Safety warnings for the electrician Connect the hood to the mains supply via a double pole switch which has 3 mm minimum separation between the contacts. The switch must be accessible at all times. The following is valid in the United Kingdom only: -the wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black, -the wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red. 40 Installation Mounting accessories included 4 screws 5 x 45 mm 4 wall plugs (brick fixing) O 8 mm 4 screws 4,2 x 35 mm 1 flange O 125 mm 1 allen spanner (for TORX screws) 1 screw 2.9 x 13 Wall unit mounting • Make the holes on the bottom of the cupboard (2), using the drilling template (1). Make a hole for the exhaust pipe (4) if the hood is to be used in the extraction version (3). • From inside the cupboard, insert the 4 supplied s...

Questo manuale è adatto anche per i modelli :
Fans - U24211 EFT 530 (516.87 kb)
Fans - U24211 EFT 635 (516.87 kb)
Fans - U24211 EFT 630 (516.87 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie