|
Facilità d'uso
Fig. 6-7. • Depending on the wall unit height, you need for return air operation a pipe union or additionally a non-flammable length of pipe (O 100/115/ 120 mm) as far as the ceiling of the wall unit. Fig. 6 Fig. 7 72 Outlet hole - Only for models DF 6260, DF 6260-ml/1 and CHDF 6260 (extractor-filter version) • When used as an extractor unit, the hood must be fitted with a 150mm diameter hose. Only for model DF 6260 - DF 6260-ml/1: Should there already be a pipe of diameter 125 mm that ducts to the outside through the walls or roof, it is possible to use the 150/125 mm reduction flange provided. In this case the hood will be slightly more noisy. Fix the flange on the hood outlet hole, using 2 screws. Fig. 8a. Filter version only • Fix the deflector to the flange. Fig. 8b. Outlet hole - Only for model DF 6160(extractor-filter version) • When used as an extractor unit, the hood must be fitted with a 120mm diameter hose. • The dimensions and position of the air outlet are given in figure 9. • Using the adapter, O100, O110 and O125 mm exhausting pipes can be used. O 125 mm exhausting hose: insert the adapter on the flange and remove, using a proper tool, the upper unused O 100 and O 110 mm rings of the adapter. O 110 mm exhausting pipe: same procedure, but removing the O 100 mm ring only. O 100 mm exhausting pipe: apply the adapter on the flange. Fig. 8a Fig. 8b Fig. 9 Fig. 10 A Spice rack • If a spice rack is to be incorporated in front of the hood, a minimum distance of 5 mm must be provided between the front edge of the fume extractor hood and the spice rack wall (this air gap being necessary for air circulation). • The upper part of the spice rack rear wall should be detachable (access for exhaust air hose or adjustment of furniture housing). Installing the extractor hood in the wall unit - extraction version (Recirculation version with charcoal filter) • Fix the drilling template to the inside wall of the wall unit on the right and left sides, and mark out and predrill O 2 mm mounting holes as well as 2 x O 6 mm - 5 mm depth holes for the mounting claws (installation aids). • Unscrew the ventilation grill mounted on the appliance (1 screw), apply the exhaust air union prepared to the required exhaust air diameter, and twist it to the right to its fullest extent (so that it is retained). • Fully withdraw the visor of the hood. • Important: Detach and insert the grease filters only when the visor is fully withdrawn. Remove the grease filters. First remove the rear and then the front grease filter. • For 19 mm side walls, the spacer discs clipped in on the appliance body must be taken out. Mount the hood with 4 or 6 x O 4 mm screws. Fig. 11. • Insert the hood in the furniture housing and engage both mounting claws (installation aids) on the right and left sides in the side wall of the wall unit and firmly hold the hood for ...
Questo manuale è adatto anche per i modelli :Fans - COOKER HOOD CHDF 6260 (613.74 kb)
Fans - COOKER HOOD DF 6160 (613.74 kb)
Fans - COOKER HOOD DF 6160 (613.74 kb)
Fans - COOKER HOOD DF 6160 (613.74 kb)