Inspect joints of the firebox as well as the points of sealing between the firebox and the finishing materials. When a firebox is installed in a chase or on an outside wall, the enclosure should be insulated like any other outside wall of the home. Plywood or hardboard may be placed on the standoffs and insulation placed on this surface. (Fig. 8) UVSTR / UVCVR Series Vent-Free Fireboxes Finishing FP681 Hard Flat Surface Insulation Platform See Page 5, Figure 3 for allowable finishing materials and clearances to combustibles. All joints (top, bottom and sides), where the wall or decorative facing material meets the firebox surround must be completely sealed with a noncombustible material. Refer to Figures 9-12. Hearth Extension A hearth extension may be used but is not required for these fireboxes. Fig. 7 Insulation between firebox and platform. FP684 Top View Noncombustible Caulking/Insulation 2 x 4 Stud Finishing MaterialFireplace Front Standoff FP682 Insulation Plywood Support Fig. 9 Seal spaces between firebox and finishing materials. FP683 Finished Wall Stud 2 x 4 Finished Header Standoff Mantel Shelf See mantel drawing for shelf-to-surround dimen- sion Seal with noncombus- tible material ONLY Surround Fireplace Front Side View 1/2" Finished Wall May be sealed with noncombustible material Fireplace Front Top View Fig. 8 Additional insulating methods. UVSTR36 shown. Fig. 10 Surround flush with finished wall. UVSTR / UVCVR Series Vent-Free Fireboxes FP610 Finished Wall Must be sealed with noncombustible mate- rial Noncombustible Decorative Fac- ing Surround 2 x 4 Finished Header Standoff Fig. 11 Appliance surround flush with finish wall. FP611 Fig. 12 Facing on firebox flush with finished wall. Finished Wall 2 x 4 Finished Header Covered Wall Must be sealed with non- combustible material Standoff Noncombustible Decorative Fac- ing Surround Install Hood A 2" or 4" Hood can be purchased for the UVSTR36 and the UVCVR36. A Hood must be installed if the mantel falls within the dimensions and location shown in Figure 3. Failure to do so may create a fire hazard. WARNING: When the black surround is covered by a brick surface, (Fig. 13), use an extended hood. The hood should extend out to the brick surface (Refer to Figs. 13 and 14) and be attached to the firebox. The maximum brick to noncombustible surface that may extend out past the black surround surface is 4...". The size of the Hood required depends on BTU ratings and clearances. See the Accessories section on Page 13 for details. Fig. 13 Side view of firebox with extended hood. FP685 4..." Max. Brick Sur- face Extended Hood Screw (Fastens to side rail from inside hood) Use Top Slot Slot Screw FP613 Fig. 14 Hood location. UVSTR / UVCVR Series Vent-Free Fireboxes Maintenance Keep the control compartment, logs and burner area surrounding the logs clean by carefully vacuuming or brushing at least twice a year or as necessary. THE LOGS CAN GET VERY HOT – HANDLE ONLY WHEN COOL. Always turn off the gas to the pilot before cleaning. For relighting, refer to the lighting instructions located on the Rating Plate of the gas log set. Never obstruct the flow of combustion and ventilation air, Keep the front of the appliance clear of all obstacles and materials. Leave at least a 36" clearance from the front of the firebox to any room furnishings. Contact CFM Corporation for questions concerning prices and policies covering replacement parts. Parts may be ordered through your Majestic Fireplaces distributor or dealer. You will need the following information when ordering replacement parts: 1. The appliance model number. 2. The serial number. 3. A description of the part. Should you need additional information beyond what your dealer can furnish, contact: CFM Corporation 410 Admiral Meadowvale Blvd. Mississauga, Ontario Canada L5N 8A3 Firebox Model and serial numbers are listed on the rating plate (located on right side of combustion chamber). Record your model and serial numbers here for future reference: Model # ____________________________ Serial # ____________________________ Vent-free Log Heater Record your model and serial numbers here for future reference: Model # ____________________________ Serial # ____________________________ 10 7412960 UVSTR / UVCVR Series Vent-Free Fireboxes 7 1 2 4 5 6 3 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. UVCVR Vent Free Firebox Ref. Description UVCVR 1. Brick - Filler 3079148 2. Brick - Side 3079147 3. Brick - Hearth 3087102 4. Screen Assembly (Screens and Rod) 3036118 5. Brick - Hearth End 3090102 6. Screen Assembly - End 3080137 7. O.S.A. Assy. 20003212 7412960 11 UVSTR / UVCVR Series Vent-Free Fireboxes 1 2 3 4 5 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. UVSTR Vent Free Firebox Ref. Description UV...
Questo manuale è adatto anche per i modelli :Fans - UVSTR36 (457.26 kb)