|
Facilità d'uso
NOTE: Place the parts from the loose parts bags ! WARNING Do not install or use fan if any part is damaged or missing. Call Toll-Free: 1-800-654-3545 ! WARNING This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Company. Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage. in small containers to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding. NOTE: Fan blades are ordered separately and are packaged in separate carton. 1. Open styrofoam unit containing fan. Remove top half of styrofoam unit. Remove parts and check to see that you have received the following: a. Fan motor and housing assembly b. One motor cover c. One ceiling cover d. Five blade flanges e. One hanger ball/downrod assembly f. One hanger bracket g. One switch housing cover h. One uplight lead assembly i. One loose parts bag containing: 1. One setscrew 2. One 5/32" hex wrench 3. Eleven 10-32 x 5/8" oval head screws 4. Two 1” threaded studs 5. Two 1-1/4” threaded studs 6. Four knurled knobs 7. Three wire connectors 8. Two screws 8-32 x 3/8" 9. Two pull chain pendants, and couplings 10. One hairpin clip 11. One clevis pin 12. Two lockwashers 13. Sixteen 10-32 x 3/8" pan head screws FOAM PACKING PROTECTIVE PLASTIC BAG FOAM PACKING CARTON MOTOR AND HOUSING ASSEMBLY HANGER BALL/ DOWNROD ASSEMBLY HANGER BRACKET LOOSE PARTS BAG BLADE FLANGES SWITCH HOUSING COVER CEILING COVER MOTOR COVER UPLIGHT LEAD ASSEMBLY 14. Sixteen flat washers 3 Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds. If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. WARNING ! To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt. If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture. SECTION A Assembly Instructions for Installing the CF2300 Ceiling Fan with a SR120 Remote Control or with a SW140 Wall Control WARNING ! If the CF2300 ceiling fan is being installed with any other control method, skip SECTION A and go to SECTION Bto begin assembly instructions. 1. Cut the white, blue, and black wires about 3" above the motor coupling (Figure 1). Strip insulation 1/2" from end of wires and install a wire connector on the black wire; this wire will not be used. Remove the wire connectors from the red and brown wires. Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock. WARNING ! To avoid fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician. WARNING ! 2. Loosen the setscrew in the hanger ball, slide the ball down the downrod, and remove the clevis pin. Then slide the hanger ball off the downrod (Figure 2). Retain all parts for reinstallation in step 11. 3" WHITE WIRE BLACK WIRE BLUE WIRE REMOVE WIRE CONNECTORS FROM RED AND BROWN WIRES INSULATE BLACK WIRE USING WIRE CONNECTOR YELLOW WIRE MOTOR COUPLING MOTOR COUPLING SLOT Figure 1 The Emerson CF2300 Ceiling Fan is designed to be operated from a SR120 Remote Control, from a SW140 Wall Control, or from other fan/light controls. There are no controls supplied with the ceiling fan. If you are going to control your ceiling fan with a SR120 Remote Control or with a SW140 Wall Control, proceed to “SECTION A”. If you are going to control your ceiling fan in any other manner, proceed to “SECTION B”. Uplight This fan is supplied with a built-in uplight in the motor housing. This uplight does not have a built-in switch to turn it ON or OFF. A separate switch control must be used to operate the uplight. This can be done with a separate ON/OFF wall switch or one of the many Emerson Fan/Light Controls, such as the SR120, SW140 or SW95L controls. The yellow lead supplied with this fan is the power lead for the uplight. SETSCREWCLEVIS PIN HANGER BALL DOWNROD Figure 2 3. Push the wiring harness connector and the connector on the blue wire (both supplied with the SR120 Remote Contr...
Questo manuale è adatto anche per i modelli :Fans - CF2300OB01 (312.04 kb)
Fans - CF2300TG01 (312.04 kb)
Fans - CF2300WB01 (312.04 kb)