Log:
valutazioni - 2, GPA: 3.5 ( )

Istruzioni per l'uso Universal Metal Industries, Modello ULT2830

Produttore : Universal Metal Industries
File Size : 99.36 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Always observe local building codes. Always use a dedicated circuit. The Trade-Wind® hood is supplied with a 5.0 amp variable speed fan control. Wire connections: (See Diagram Below) There are 3 wires on the front panel that require connection. BLACK 120 VAC from electrical panel (usually black) WHITE Neutral from electrical panel (white) GREEN Ground from electrical panel (usually green) CAUTION: The neutral wire (white) must only be connected to the white neutral wire coming in from the electrical panel. Hood BLK WHT GRN House Electrical Panel Green White 120V Black (L) PART 3 Determining Direction of Vent and Securing the Hood MOUNTING HOLES: Because the Trade-Wind® Ultra Series rangehood was designed for all applications, no mounting holes have been pre-drilled. This allows the hood (or liner) to be attached in the areas of the cabinet or wood hood canopy that have proper wood frame support. The hood should be attached to the wood framing through the top. Remove the filters. Mark and drill screw holes through the hood as required. Secure the hood by driving screws (provided by others) through the screw holes. NOTE: DRILLING THROUGH STAINLESS STEEL REQUIRES TITANIUM DRILL BITS. BE CAREFUL NOT TO DRILL THROUGH THE UL LABEL OR INTO THE HOOD’S ELECTRICAL COMPONENTS. DETERMINING THE DIRECTION OF VENTING (TOP, REAR AND RECIRCULATE): TOP VENT BACK VENT RECIRCULATION IMPORTANT NOTE: If hood is to be vented out the Top or Back, the charcoal filters must be removed. Top Vent: Range hoods are shipped with the motor and blower installed to vent out the top. However, the vent covers in the rear vent opening and recirculation vent opening must be taped on all edges to prevent air leaks and vibration noise. The vent covers are not taped when shipped from the factory because the direction of venting may be changed. Vent covers can be placed on either the outside or inside of the hood. Vent covers placed on the inside of the hood should be neatly foil taped. Duct covers placed on the outside of the hood can be duct taped. If the rear vent and recirculation vent covers are not already in place, slightly bow the vent cover and place the side slots over both sides of the vent openings. Tightly fasten the motor & blower housing to the studs on the hood top. When installed correctly, the motor & blower housing will be approximately .” from the back wall of the hood. Back Vent: Unplug the electrical connection and remove the motor & blower housing from the hood. IMPORTANT: Remove the vent cover from the rear vent opening. Slightly bow the vent cover removed from the rear vent opening and place the side slots over both sides of the top vent opening. The vent cover can be placed on the inside or outside of the hood. We recommend the inside. Vent covers placed on the inside of the hood should be neatly foil taped. Vent covers placed on the outside of the hood can be duct taped. Vent covers must be taped on all edges to prevent air leaks and vibration noise. Do not re-use the pieces of duct tape shipped with the hood. Reposition the blower housing to vent out the back of the hood and align the housing mounting brackets so that the housing tightly fits against the back wall. Securely fasten the motor & blower housing to the studs on the hood top. Reconnect the electrical connectors. Recirculation: Note: “NRV” Models (No Recirculation Vent) do not have the recirculation feature. Unplug the electrical connection and remove the motor & blower housing from the hood. IMPORTANT: Remove the vent cover from the front vent opening. Slightly bow the vent cover removed from the front vent opening and place the side slots over both sides of the top vent opening. The vent cover can be placed on the inside or outside of the hood. We recommend the inside. Vent covers placed on the inside of the hood should be neatly foil taped. Vent covers placed on the outside of the hood can be duct taped. Vent covers must be taped on all edges to prevent air leaks and vibration noise. Reposition the blower housing to vent out the front of the hood and align the housing mounting brackets so that the housing tightly fits against the front wall. Securely fasten the motor & blower housing to the studs on the hood top. Reconnect the electrical connectors. Charcoal Filters: Charcoal Filters remove cooking odors. When properly installed in the hood, the charcoal material should be on the top side of the filter and not visible. Charcoal filters will not remove odors ...

Questo manuale è adatto anche per i modelli :
Fans - ULT2824 (99.36 kb)
Fans - ULT2820 (99.36 kb)
Fans - ULT2836 (99.36 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie