|
Facilità d'uso
Follow the dimensions shown in the Installation illustration on page 4. Wolf Pro wall hoods are shipped without a blower assembly. Internal, in-line or remote blower assemblies are available. Blower options also vary with the volume of air that needs to be moved and the length of the duct run. Refer to the charts at the end of this section for Pro ventilation recommendations and blower options. IMPORTANT NOTE: Install this ventilation hood only with a Wolf blower. Pro wall hoods require a separate, grounded 110/120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker. Placement of the electrical supply is not critical, as long as you provide enough 120 V AC, 60 Hz power cable to make the electrical connection. Locate electrical within the shaded area shown in the Installation illustration on page 4. You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. Refer to the installation instructions shipped with each Wolf product for detailed specifications. This information can also be found on our website, wolfappliance.com. Dimensions in parentheses are in millimeters unless otherwise specified. 5 Planning Information Planning Information Pro 24" (610) Deep Wall Ventilation Hood MODEL PW302418(R) DUCTING CONSIDERATIONS Wolf Pro 24" (610) deep wall hoods are shipped without the blower assembly. Internal, in-line and remote blower assemblies are available. IMPORTANT NOTE: Install this ventilation hood only with a Wolf blower. Pro 24" (610) deep wall hoods have a vertical discharge. A horizontal discharge kit is available as a sales accessory. The hood will operate most efficiently when ductwork does not exceed 50' (15 m) in length. Local building codes may require the use of make-up air. Consult your local HVAC professional for specific requirements in your area. IMPORTANT NOTE: Wolf Pro 24" (610) deep wall hoods must be vented to the outside except when used with the accessory recirculating kit with the 600 CFM blower. Use only metal ductwork. Refer to the illustration below for ducting considerations for Pro 24" (610) deep wall hoods. Ducting for Pro 24" (610) deep wall hoods. DUCTWORK INSTALLATION THROUGH ROOF 24" (610) DEPTH OF HOOD ROOF CAP OR REMOTE BLOWER 10" (254) ROUND DUCT SOFFIT OR CABINET OR DUCT COVER NOTE: HORIZONTAL DISCHARGE REQUIRES AN ACCESSORY KIT. VERTICAL DISCHARGE TRANSITION 221/4"W x 9"D TO 10" ROUND 10"H (INCLUDING FLANGES) 30" TO 36" (762–914) COUNTERTOP TO BOTTOM OF VENTILATION HOOD 36" (914) STANDARD FLOOR TO COUNTERTOP HEIGHT 18" (457) HEIGHT OF HOOD WALL HOOD Dimensions in parentheses are in millimeters unless otherwise specified. 6 Planning Information Planning Information Pro 24" (610) Deep Wall Ventilation Hood MODEL PW302418(R) WOLF BLOWER ASSEMBLIES A ventilation system must include a blower assembly. Wolf ventilation hoods are shipped without the blower assembly. An internal, in-line or remote blower assembly must be selected to accommodate the cooking appliance, CFM requirements and homeowner preferences. Internal, in-line and remote blower assemblies are available as sales accessories through your Wolf dealer. IMPORTANT NOTE: Use only a Wolf blower with all Wolf ventilation products. 113/4" (298) 211/2" (546) 243/8" (619) 181/2" (470) 121/4" (311) 41/2" (114) 18" (457) 22" 247/8" (632) 12" (305) 18" 8" (203) Internal blowers are mounted inside the hood canopy. In-line blowers are mounted in between the hood and the exterior of the home. Remote blowers can be mounted on the roof or in some cases, on an exterior wall. Refer to the illustrations below for dimensions of Wolf in-line and remote blowers. Pro ventilation recommendation charts on the following page provide minimum CFM recommendations according to the cooking appliance and ventilation hood used and blower options for each specific Pro 24" (610) deep wall hood. (559) (457) In-line BLOWER-60IL In-line BLOWER-110IL 241/2" (622) 151/2" (394) 281/4" (718) 203/4" (527) 243/4" (629) 14" (356) 43/4" (121) 10" (254) Diameter 143/4" (375) 291/2" (749) 291/2" (749) 18" (457) 22" (559) 101/8" (257) 71/4" (184) 10" (254) 10" (254) Diameter 143/4" (375) 291/2" (749) 291/2" (749) 21" (533) 25" (635) 103/8" (264) 71/4" (184) 10" (254) 10" (254) Diameter Remote BLOWER-60REM and Remote BLOWER-120REM Remote BLOWER-150REM BLOWER-90REM Unit dimensions may vary by ± 1/8" (3). Dimensions in parentheses are in millimeters unless otherwise specified. 7 Planning Information Planning Information Pro 24" (610) Deep Wall Ventilation Hood MODEL PW302418(R) PRO VENTILATION CFM RECOMMENDATIONS Pro 24" (610) Deep Wall Hoods Model PW302418 PW362418 PW422418 PW482418 PW542418 PW602418 PW662418 DF304 / R304 / SRT304 600 600 DF366 / R366 / SRT366 / RT366 900 900 DF364 / R364 / SRT364 / RT364 900 900 RT362 900 900 R488 / RT488 1100 1100 DF486 / R486 / SRT486 / RT486 1100 1100 DF484 / R484 / SRT484 / RT484 1100 1100 DF606 / R606 1500 1500 DF604 15...
Questo manuale è adatto anche per i modelli :Fans - PW302418 (226.78 kb)