Facilità d'uso


It must be firmly attached to the stud framing behind the drywall. If studs are not available in the required locations, a plywood backing (min. 1/2" (13 mm) thick) spanning at least two studs must be installed. Failure to adequately support the weight as stated may result in the ventilation system falling off the wall, causing personal injury and property damage. (If plywood backing is not needed, proceed to the included installation sheet.) To install a plywood backing ^Determine and mark the location of the retaining plate for the canopy as outlined on the installation sheet. ^Make a cutting line 3" (76 mm) above and 3" (76 mm) below the outline of the retaining plate. ^ Find the studs to the left and right of the mounting location by tapping the wall or using a stud finder. ^ Mark a vertical cutting line along the center of each stud. Be careful not to damage any wiring or plumbing that may be located behind the wall. Make sure that the power supply to the area where this installation is being performed has been turned off at the breaker panel before cutting into the wall. ^ Remove the drywall between the cutting lines and replace it with plywood of a matching thickness (min. 1/2" (13 mm) thick). Tape the joints and refinish the wall. ^ Proceed to the included installation sheet to complete the installation. Electrical data All electrical work should be performed by a qualified electrician in strict accordance with national and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. The manufacturer can not be held responsible for unauthorized work. Ensure that power to the appliance is OFF while installation or repair work is performed. Important The hood comes equippped with a 5 ft (1.5 m) power cord with a NEMA 5-15 molded plug for connection to a 120 VAC, 60 Hz, 15 A power outlet. Maximum load. . . . . . . . . . . . . .390 W Lighting . . . . . . . . . . . . . . . . . .2 x 20 W Voltage . . . . . . . . . . . . . . . . . . . . . 120 V Frequency . . . . . . . . . . . . . . . . . .60 Hz Verify that the voltage, load and circuit Circuit rating. . . . . . . . . . . . . . . . . .15 A rating information found on the data plate (located behind the grease filter), match the household electrical supply before installing the hood. If there is any question concerning the electrical connection of this appliance to your power supply, please consult a licensed electrician or call Miele’s Technical Service Department. U 1-800-999-1360 V 1-800-565-6435 WARNING: THIS APPLIANCE MUST BE GROUNDED Appliance dimensions Appliance dimensions 1) Air outlet installed upwards for recirculation mode 2) and 3) Cut out area in wall or ceiling for entrance of 6" (150 mm) ductwork or 5" (125 mm) ductwork with a reducing collar. For recirculation mode only 2) and outlet installation are necessary. Do not install this exhaust hood over cooktops burning solid fuel. When installing the hood, make sure that the following minimum distance (S) between the top of a cooking surface and the bottom of the hood is: -22" (55 cm) above electric cooktops -26" (65 cm) above gas cooktops -26" (65 cm) above an open grill Follow the safety distances recommended by the cooktop manufacturer in their installation and operating instructions. If there is more than one appliance beneath the hood and they have different minimum safety distances always select the greater distance. See "Warning and Safety instructions" for further information. 26" (65 cm) is recommended for all installations to allow for optimum work space under the hood. Distance between cooktop and hood (S) The installation procedure differs depending on the model and venting method. Before beginning the installation: ^ Read all instructions. ^ Determine height (S), regarding the user’s body height, i.e. a comfortable height for the user. However, the greater the distance, the less effectively cooking odors are drawn in. ^ If the hood is fitted flush to the ceiling make sure that the remaining distance to the ceiling is not greater or less than appliance height H. Standard unit height H Air Extraction . . . . . . . . . . .28 3/16" - 38" . . . . . . . . . . . . . . . . . . . (716 - 966 mm) Recirculation. . . . . . . . . . . . . . . 33" - 42" . . . . . . . . . . . . . . . . . . (836 - 1066 mm) If the standard unit height H is not suitable to the kitchen’s ceiling height, longer optional chimney extensions are available from your Miele dealer or Miele. Installation Installation instructions ^ See the enclosed installation instruction sheet. ^ Please read the "Important Safety Instructions" and Installation instructions before installing this hood. Protective film The casing is covered with a protective film to prevent scratching during transport. ^ Peel off the film before installing the casing parts. Dismantling If the hood needs to be disassembled, follow the instructions on the installation sheet in the reverse order. A lever is enclosed for e...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie