|
Facilità d'uso
0.04 mbar. The safe joint operation of chimney-linked appliances and fume extractor hoods is only guaranteed if space and/or dwelling (space/air interaction) are externally ventilated by a suitable supply air opening of around 500—600 cm2 and an underpressure thereby avoided when the fume extractor hood is running. SIE2 5/90 - SIKM1 11/89 GB/EU SIKM1 11/89 - SIKM3 5/90 GB/EU In doubtful cases, please seek the advice and consent of the competent area chimney-sweep or the local building authorities. Since, in spaces without fireplace, the rule is: “Supply air opening as large as exhaust air opening”, the efficiency of the exhaust air device may be impaired by the greater opening of 500-600 cm2. Operation of the hood as a return air hood in such circumstances is safe and is not subject to the regulations noted above. Operation of the fume extractor hood in return air mode is optimum only when the following are ensured: — short, straight exhaust air runs — as few pipe bends as possible — running of pipes in flat arcs, not in acute angles — as large as possible pipe diameters (basically min. 120 mm dia. for two-motor hoods). Failure to observe these principles is inevitably associated with power losses and increased operating noise. During installation of the fume extractor hood, the following minimum distances from the upper edge of the hob to the lower edge of the fume extractor hood must be complied with: Electric cookers 650 mm Gas cookers 650 mm Coal- and oil-fired cookers min. 700 mm For the kitchen furniture installer General Appliance description The fume extractor hood is supplied as an exhaust air appliance and may be used as a return air appliance through application of an active carbon filtre (special accessory). For this purpose, you need the AEG Original Active Carbon Filter (see special accessories). A = Light switch B = Blower switch (On/Off) C = Blower switch settings D = Metal filter grille (fat filter) The fume extractor hood is switched on and controlled via the different controls Technical data Dimensions: 860 D Height Width Depth (in mm) 255 599 490 Weight: Net: 22 kg 8609 D Height 255 Width 899 Depth 497 (in mm) Weight: Net: 24.5 kg AL1 11/89 - GBM3 5/90 - TDM1A 5/90 GB/EU TDM2B 5/90 - TDM3A 5/90 - LAD3 5/90 GB/EU Connection value: 860 D 8609 D Total connected load: 179 W 180 W Fan motor: 2 x 82 W 2 x 82 W Lighting: 1x 15 W 1x 16 W {fluorescent lamp) (fl. lamp) Fan outputs (settings) to DIN 44 971 860/8609 D Setting 1 Setting 2 Setting 3 Setting 4 Exhaust air: 200 m3/h 320 m3/h 400 m3/h 520 m3/h Return air: 140 m3/h 240 m3/h 290 m3/h 360 m3/h Exhaust air system 125 mm dia. Air outlet arranged centrally above Pipe connection of 125 mm dia. for exhaust air hoses of 125 mm dia. Air outlet Draufsicht = Plan 31 Accessories/installation materials Preparing for exhaust air operation 1 wall rail (for mounting of fume extractor hood) 4 wall plugs for 8 mm, 40 mm long wood sc...
Questo manuale è adatto anche per i modelli :Fans - 860 D (574.54 kb)
Fans - 860 D (574.54 kb)
Fans - 8609 D (574.54 kb)
Fans - 8609 D (574.54 kb)