1. Remove any tape that might be holding the damper in place during shipping and connect the ducting to the fan’s duct collar (Figure 8). Secure in place using tape or screw clamp. Always duct the fan to the outside through a wall or roof cap. Figure 8 SECTION 5 Wiring CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. WARNING: THIS UNIT MUST BE WIRED ON A SEPARATE 20 AMP CIRCUIT. CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN. 210572111 Rev. B 5-06 3 of 8 1. Run wiring from approved wall switches carrying SECTION 6 the appropriate rating. One neutral (white), one Completing the Installation ground (green or bare copper), and three hot (black, red, blue leads connected to the switch, one for 1. Insert the plug from the heating unit into the each function). Secure the electrical wires to the receptacle marked “HEAT”, and the plug from the housing with an approved electrical connector. Make fan into the receptacle marked “VENT”(Figure 11). sure you leave enough wiring in the box to make the connection to the fan’s receptacles. 2. Connect the white wire from the house to the three white wires from the fan. Connect one hot (black) wire from the wall switch to the black wire from the fan (this is the fan control). Connect second hot (red) wire from the wall switch to the red wire from the fan (this is the heat control). Connect the third hot (blue) wire from the wall switch to the blue wire from the fan (this is the light control). Connect the ground wire from the house to the green wire from the fan (Figure 9). Use approved methods for all connections. 210572111 Rev. B 5-06 3. Reinstall the wire compartment cover by sliding the tabs at the bottom of the cover into the slots in the housing. Make sure all wires are tucked inside of the compartment and are not being pinched or showing through. Reinstall the two screws removed in Step 3 of SECTION 1 Preparing the Unit(Figure 10). Figure 9 Ground Supply from house White Hot (Blue) Hot (Black)Hot (Red) Figure 10 Tab Slot Light 2. Remove grill from carton and open light lens area by pushing in on the two tabs of the light lens and pulling outward from lens. The lens will swing open on the connector bars. DO NOT remove the lens from the grill (Figure 12). 3. Install light reflector into grill by lining up the posts on grill with the holes in light reflector (Figure 13). Raise light reflector and grill up to housing and insert plug from light into receptacle marked “LIGHT” (Figure 11). 4 of 8 Figure 12 Tabs Connector Bar Figure 13 Hole Post Post Figure 11 Heater Vent 4. Attach light reflector in place with the two screws removed during Step 2in SECTION 1 Preparing the Unitso grill fits snuggly against ceiling (Figure 14). Figure 14 Screws CAUTION: FAILURE TO SECURE THE REFLECTOR SCREWS MAY RESULT IN A RATTLING OR HUMMING NOISE. 5. Install a 100 watt maximum, type A19 medium base incandescent bulb (not included). 6. Close the light lens and secure in place by swinging back into position and snapping the tabs in place (Figure 15). Figure 15 Tabs Connector Bar 7. Restore power and test your installation. SECTION 7 Use and Care CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT. 1. Cleaning the Grill: Reverse the instructions in Section 6 Completing the Installationto remove grill. Use a mild detergent, such as dishwashing liquid, and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Completely dry grill before reinstalling. Refer to instructions in Section 6 Completing the Installation, to reinstall grill. 2. Cleaning the Fan Assembly: Wipe all parts with a dry cloth or gently vacuum the fan. NEVER IMMERSE ELECTRICAL PARTS IN WATER. CAUTION: ALLOW BULBS TO COOL BEFORE REPLACING. 3. Changing the Light Bulb: Disconnect power to the unit. Open light lens by pushing in on the two tabs of light lens and pulling outward from lens. The lens will swing open on the connector bars. DO NOT remove the lens from the grill (Figure 16). Figure 16 Tabs Connector Bar 4.Unscrew bulb from lamp holder and replace with a 100 watt maximum, type A19 medium base incandescent bulb. Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1. Fan does not operate when the switch is on. 2. Fan is operating, but air moves slower than normal. 3. Fan is operating louder than normal. 1a. A fuse may be blown or a circuit tripped. 1b. Connector plug from motor is not plugged in. 1c. Wiring is not connected properly. 2. Obstruction in the exhaust ducting. 3a. Motor is loose. 3b. Fan blade is hitting housing of unit. 1a. Replace fuse or reset circuit breaker. 1b. Turn off power to unit. Remove Grill and plug motor into receptacle in housing. Restore power to unit. 1c. Turn off power to...
Questo manuale è adatto anche per i modelli :Fans - BFLH70L (158.7 kb)