Log:
valutazioni - 3, GPA: 4 ( )

Istruzioni per l'uso GE, Modello GE Monogram 49-80565

Produttore : GE
File Size : 594.04 kb
File Nome : 835ff7b3-ffbf-47a6-bef3-9c504ea0adf6.pdf
Lingua di insegnamento: enesfr
Vai a scaricare



Facilità d'uso


It remembers the last light level used. The buttons allow you to cycle around to the desired setting. (There are four light levels/settings and OFF.) 5. POWER ON/OFF. Press to activate (turn on)/deactivate (turn off) the control buttons. When the buttons are active (turned on), their outer rings will be illuminated. When active (turned on), the hood lights and fan will automatically turn on at their last settings. NOTES: • Always deactivate (turn off) the buttons when the hood is not in use. • If both the LIGHT and FAN are set to OFF, the buttons will automatically deactivate (turn off) after 10 seconds. 1 2 3 54 Care and Cleaning Custom Hood Insert For your safety Before servicing or cleaning the unit, switch power off at the service panel and lock the service panel to prevent power from being switched on accidentally. If the service panel cannot be locked, fasten a tag or prominent warning label to the panel. Metal grease filters The metal filters trap grease released by foods on the cooktop. The filters also help prevent flames (from food, grease) from damaging the inside of the hood. For this reason, the filters must ALWAYS be in place when the hood is used. The grease filters should be cleaned every 6 months, or as needed. To remove: Support the filter with one hand while pulling down filter clip with the other. Pull the filter down and out. To replace: 1. Tip the filter into the back tab slots and lift up. 2. While maintaining slight upward pressure on filter, open clip and press into place with two hands. To clean, swish the filter in hot soapy water and rinse in clean water or wash it in the dishwasher. Do not use abrasive cleansers. Clip Clip Care and Cleaning Custom Hood Insert Stainless steel hood surfaces Do not use a steel wool pad; it will scratch the surface. To clean the stainless steel surface, use warm sudsy water or a stainless steel cleaner or polish. Always wipe the surface in the direction of the grain. Follow the cleaner instructions for cleaning the stainless steel surface. To inquire about purchasing stainless steel appliance cleaner or polish, or to find the location of a dealer nearest you, please call our toll-free number: National Parts Center 800.626.2002 monogram.com Light bulbs To change the light bulbs: 1. Grasp the outer trim ring and twist until reaching the unlock position. Then pull the ring straight out. 2. Grasp the bulb and twist until reaching the unlock position. Then gently pull the bulb straight out. 3. Replace with the same wattage, type and size bulb. Wear gloves. Do not touch bulb with your bare fingers. These 120 volt, 50 watt halogen bulbs with a GU10 base are available at specialty lighting stores and home building centers. 4. Replace the outer trim ring by inserting the two retaining tabs into the two tab slots, pressing the ring flush with the surface of the hood insert and twisting until reaching the lock position. The Problem Solver Custom Hood Insert Questions? PROBLEM POSSIBLE CAUSE Use this problem solver! FAN AUTOMATICALLY • The Sensor feature will automatically turn the fan on at the TURNS ON AND CAN MED setting if cooking temperatures become too hot. The fan NOT BE TURNED OFF will stay on for a minimum of 3 minutes and will then turn off when temperatures cool to an appropriate level. FAN DOES NOT • A fuse may be blown or a circuit breaker tripped. Replace fuse or OPERATE WHEN reset circuit breaker. TURNED ON • The power disconnect switch inside the hood may be switched off. Remove the metal grease filters and flip the switch on. FAN FAILS TO CIRCULATE • Check to be sure the metal grease filters are clean. Clean the metal AIR OR MOVES AIR grease filters (see the Metal grease filters section). If cleaning SLOWER THAN NORMAL the filters does not correct the problem, call for service. FAN KEEPS GOING OFF AND ON • The motor is probably overheating and turning itself off. This can be harmful to the motor. Check to be sure the filters are clean. If off and on cycling continues, call for service. LIGHT WILL NOT STAY ON HIGH SETTING • Use 120 volt, 50 watt halogen bulbs with a GU10 base and make sure they are inserted securely. See the Light bulbs section. THE HOOD CONTROLS • Disconnect power to the hood by removing the fuse or turning the ARE NOT OPERATING circuit breaker off in the home fuse box. Wait 30 seconds to allow the CORRECTLY hood controls to reset and then replace the fuse or move the circuit breaker back on. SEQUENTIAL PRESSES OF THE LIGHT OR FAN BUTTONS WILL SOMETIMES CHANGE THE SETTING FROM THE LOWEST SETTING–TO OFF– TO THE HIGHEST SETTING, OR FROM THE HIGHEST SETTING–TO OFF–TO THE LOWEST SETTING • It is normal for the light and fan buttons to cycle around through the settings so that you can easily set the controls to the desired setting. WHEN PRESSING THE • For your convenience, it is normal for the lights and fan to remember POWER ON/OFF BUTTON their last setting when you press the Power On/Off button. If you TO TURN ON THE LIGHT, want on...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie