Log:
Scaricare : 2   File Size : 5 mb   Produttore : EMI  
Categoria : Fans
@name

A field installed crankcase heater is standard on S1H 09 &12 (Thermostatically controlled) models, and is available as optional equip ment on other models. inStaller SUpplieD itemS • Power wiring • Low volt wiring (18 awg minimum) • Secure mounting pad or foundation • Refrigerant piping (if not purchased from EMI) • High Volt Disconnect • Refrigerant for charging interconnect piping (see charge table on page 10) • Compressor and fan motor contactor • Run capacitor • Loss of charge switch (09 - 1

Scaricare : 0   File Size : 698 kb   Produttore : EMI  
Categoria : Fans
@name

Design and specifications may change without notice. System performance data: matched with emi AmericaSeries indoor units S1C eleCtriCAl SpeCiFiCAtiOnS model # Volts/HZ/pH Fan motor Compressor total AmpS min Volt m.C.A. HACr BrKr AmpS Hp rlA lrA S1C9A 115/60/1 1.4 0.125 6.7 29.0 8.1 104 9.8 15 S1C2A 115/60/1 1.4 0.125 8.4 44.0 9.8 104 11.9 20 S1C9D 208/230/60/1 0.8 0.125 3.5 19.0 4.3 197 5.2 15 S1C2D 208/230/60/1 0.8 0.125 4.5 21.0 5.3 197 6.4 15 S1C8D 208/230/60/1 0.8 0.125 5.4 36.0 6.2 197 7.6

Scaricare : 0   File Size : 698 kb   Produttore : EMI  
Categoria : Fans
@name

The S1C/S1H system can be recommended for both commercial and residential use. S1C/S1H 9-24 and S1C 30-36 SIN GLE ZONE Ductless Split Condensing Unit P/N 240005841, Rev. A [05/08] Low Ambient cooling operation down to 32. F are standard on all S1H (heat pumps) factory installed (optional on S1Cs) • Low Ambient cooling operation down to 32. F – Specify this option if the S1C system will be operated in cooling mode at outside temperatures below 60. F (field installed kit) • Low Ambient controls fo





categorie