|
Facilità d'uso
. . Notify Assign and enable notifications: Mail Modem LAN 1 to LAN 5 Alert Window The selected function must be enabled: Setup menu > Network > Notification DLR -XXN/XX Setup menu, continued Setup menu... Event Video Loss Actions 2 Term Symbol Meaning No. Number of covert camera PTZ Select PTZ cameras to record in event of alarm and select the desired settings Spot Monitor Select spot monitor on which camera image is displayed in event of alarm DLR -XXN/XX Setup menu, continued Event – Text-In On the “Text-In” menu the text input device is defined and the responses to text input are configured. Setup menu... Event Text-In Settings Term Symbol Meaning No. Number of text input device Setup Configuration of text input >> Title Name of text input Setup Term Symbol Meaning Port Interface Setup… Setting as specified by manufacturer of text input device (ATM, cash-till etc.): Baud Rate Data Bit Stop Bit Parity Text-In Product Type of text input: Generic Text Epson Transaction Start Character string with which text input must start for the DVR to respond Any Character DVR responds to any character Transaction End Character string with which text input must end for the DVR to respond 0 more line(s) Enables recording of n more lines Line Delimiter Line delimiter as specified by the text input device manufacturer: ^J for LF or ^M for CR Ignore String Character string in the text input which the DVR is to ignore All transmittable character strings are specified by the text input device manufacturer. Case Sensitive Case sensitivity according to text input device manufacturer’s specification DLR -XXN/XX Setup menu, continued Setup menu... Event Text-In Actions 1 Term Symbol Meaning No. Number of alarm input Record Assignment of cameras to record in event of alarm These cameras must be in “Event” or “Time and Event” mode within the time slot: Setup menu > Record > Schedule Alarm-Out Assign and enable alarm outputs internal beep by DVR These alarm outputs and the internal beep must be enabled within the time slot: Setup menu > Devices > Alarm-Out > Schedule . . Notify Assign and enable notifications: Mail Modem LAN 1 to LAN 5 Alert Window The selected function must be enabled: Setup menu > Network > Notification Setup menu... Event Text-In Actions 2 Term Symbol Meaning No. Number of alarm input PTZ Select PTZ cameras to record in event of alarm and select the desired settings Spot Monitor Select spot monitor on which camera image is displayed in event of alarm DLR -XXN/XX Setup menu, continued Event – System Event On the “System Event” menu the self-diagnostics and corresponding messages are configured. Setup menu... Event System Event Health Check Term Symbol Meaning System System self-diagnostics interval Check Recording Setup... . Configuration of schedule >> Check Alarm-In Interval and status for checking alarm inputs Setup Term Symbol Meaning Schedule On Enables schedule entries No. Number of schedule entry Day Day of the week Range Time range at 15-minute intervals Interval Checking interval Setup menu... Event System Event Storage Term Symbol Meaning Disk Bad Notify Percentage of bad sectors on hard disk as from which an alarm is triggered Disk Almost Full Notify Percentage hard disk space available as from which “Disk Almost Full” alarm is triggered Setup… Configuration of data media S.M.A.R.T. check Opens a window in which the frequency rate and time and a temperature limit (in Celsius or Fahrenheit) for the S.M.A.R.T. check can be specified. If the temperature limit is exceeded an alarm is triggered. For details of your hard disk’s temperature limit refer to the manufacturer’s manual. DLR -XXN/XX Setup menu, continued Setup menu... Event System Event Actions Term Symbol Meaning Event Events (based on checks): System System check failed Panic Record Panic recording in progress Check Recording Recording check failed Check Alarm-In Check of alarm inputs failed Disk Almost Full Preset limit value for hard disk capacity reached Disk Full Hard disk full Disk Bad Preset limit value for number of bad sectors reached Disk Temperature Preset temperature limit reached Disk S.M.A.R.T. S.M.A.R.T. check failed Alarm-Out Assign and enable alarm outputs internal beep by DVR Note: Not possible for system event and panic recording . . Notify Assign and enable notifications: Mail Modem (not in case of system event) LAN 1 to LAN 5 (not in case of system event) Alert Window (not in case of system event) The selected function must be enabled: Setup menu > Network > Notification DLR -XXN/XX Setup menu, continued Event – Event Status The “Event Status” menu indicates the status of all possible events: . Grey text: Event detection not enabled . White text: Event detection enabled . Flashing border: Message – acute event for 5 sec . Yellow field: Pending event Setup menu... Event Event Status Event Status Term Event Alarm-In At alarm input 1 to 16 Check Alarm-In Error detected at one of alarm inputs 1 to 16 Motion Motion detected on came...
Questo manuale è adatto anche per i modelli :Video - DLR3-08N/160CD (421.8 kb)
Video - DLR3-08N/660CD (421.8 kb)
Video - DLR3-16N/160CD (421.8 kb)
Video - DLR3-16N/410CD (421.8 kb)