Facilità d'uso


w Flange-back Adjusting Ring This ring adjusts the back-focal distance or picture focus. Rotate this ring clockwise for a C-mount lens or counterclockwise for a CS- mount lens. e Lens (option) r Mount Adapter The camera mounting screw hole is for mounting the camera onto a mounting bracket. The camera is originally designed to be mounted from the bottom, however, a top- mounting type is also available. To mount from the top, remove the mount adapter from the bottom of the camera by removing two fixing screws. Attach the mount adapter to the top as shown in the diagram, then mount the camera on the mounting bracket. Make sure that two original screws are used when mounting the mount adapter; longer type screws may damage inner components, too shorter type screws may cause the camera drop. t Focus Fixing Screw y Power Cord (only for WV-CP240) Connect this power cord to an electrical outlet of 120 V AC 60 Hz. u DC 12 V Input Terminal [DC 12V IN (only for WV-CP242)] This terminal is for connecting the 12 V DC power supply cord. i AC 24 V Input Terminal [AC 24V IN (only for WV-CP244)] This terminal is for connecting the 24 V AC 60Hz power supply cord. o Synchronization Mode Selector [INT, LL (only for WV-CP240 and WVCP244)] Selects the camera synchronization mode as either internal sync mode (INT) or line-lock mode (LL). INT: Sets to internal 2:1 interlace. LL: Sets to Line-lock mode. !0 Back Light Compensation Mode Selector (BLC ON, OFF) Lets you select the mode according to the position of the object and light conditions on the screen. Caution: To prevent fire or electric shock hazard, use a UL listed cable (VW-1, style 1007) for the CONNECTIONS A. WV-CP240 (120V AC 60Hz) Installation of Auto Iris Lens DC 12 V or AC 24 V Input Terminal. Connect the power cord to an electrical outlet Connector of 120V AC 60Hz. Install the lens connector (YFE4191J100) when using a video drive ALC lens. B. WV-CP242 (12V DC) The installation should be made by qualified Connect the power cord to the DC 12V IN ter service personnel or system installers. minal on the rear panel of the WV-CP242. Cut the iris control cable at the edge of the lens connector to remove the existing lens connector and then remove the outer cable cover of the supplied connector as shown in the diagram. The pin assignment of the lens connector is as follows: Pin 1: Power source; +9 V DC, 50 mA max. Pin 2: Not used Pin 3: Video signal; 0.7 V[p-p]/40 k. Pin 4: Shield, ground MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS 12 V DC (10.5 V - 16 V) Resistance of copper wire [at 20°C (68°F)] Copper wire size (AWG) #24 (0.22mm2) #22 (0.33mm2) #20 (0.52mm2) #18 (0.83mm2) Resistance ./m 0.078 0.050 0.03. 0.018 Resistance ./ft 0.026 0.017 0.010 0.006 Solder the lens cable to the pins of the supplied connector. • Calculation of maximum cable length Pin 3 Pin 4 Pin 2 Rib Pin 1 Mounting the Lens between camera and power supply : Caution: 10.5V DC . VA . (R x 0.42 x L) . 16V DC Before you mount the lens, loosen the screw L : Cable length (meters) on the side of the camera, and rotate the flange-back adjusting ring clockwise until it R : Resistance of copper wire (./meter) stops. If the ring is not at the end, the inner VA : DC output voltage of power supply unit lens or CCD image sensor may be damaged. q Mount the lens by turning it clockwise on the VA . 12L standard = (meters) lens mount of the camera. 0.42 x R w Connect the lens cable to the auto iris lens VA . 16 connector on the side of the camera. L minimum = (meters) 0.42 x R VA . 10.5 L maximum = (meters) 0.42 x R C. WV-CP244 (24V AC 60Hz) Connect the power cable to the AC 24 V IN terminal on the rear panel of the WV-CP244. ON: Select this mode when a strong light such as a spotlight is in the background. OFF: Normal picture. Focus Fixing Screw w q cs c !1 Detail/Aperture Level Selector (SHARP, SOFT) The detail/aperture level can be selected with this selector. Set it to the desired position while observing the picture on the monitor. 24 V AC, 60 Hz Caution for Mounting the Lens (19.5 V - 28 V) SHARP: Normal position. SOFT: Select this position when a Quad The lens mount should be a C-mount or CS-mount System is connected to this camera. Recommended wire gauge sizes for 24 V AC line (1”-32UN) and the lens weight should be less than 450 g (0.99 lbs). If the lens is heavier, both the Copper wire size (AWG) #24 (0.22mm2) #22 (0.33mm2) #20 (0.52mm2) #18 (0.83mm2) Length of Cable (Approx.) (m) 95 150 255 425 (ft) 314 495 842 1 403 lens and camera should be secured by using the !2 Automatic Light Control/Electronic Light supporter. Lets you select the mode according to the Control Selector (ALC, ELC) The protrusion at the rear of the lens should be as lens type used. shown in the diagram. ALC: Select this mode when an auto iris lens (ALC lens) is used with this camera. ELC: Select this mode when a fixed iris lens Caution: or manual iris lens is used with this cam- To prevent fire or electric shock hazard, use era. a UL list...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie