Log:
valutazioni - 4, GPA: 3.3 ( )

Istruzioni per l'uso Chamberlain, Modello JOURNEYMAN HD-9240

Produttore : Chamberlain
File Size : 826.6 kb
File Nome : 595-5631-07.pdf
Lingua di insegnamento: enesfr
Vai a scaricare



Facilità d'uso


4 Installation .....................................................................................................5 Wall Mount ...............................................................................................5 Eave Mount ...............................................................................................5 Universal Adaptor.................................................................................... 6 Standard Wiring.......................................................................................6 Controlling Non-Motion Sensing Fixtures .............................................7 Finish Mounting ....................................................................................... 8 Specifications............................................................................................ 8 Test and Adjustment .................................................................................... 9 Expected Coverage .................................................................................10 Operation .................................................................................................... 12 Troubleshooting Guide.............................................................................. 13 JourneyMan® Lifetime Warranty ...............................................................14 -2-595-5631-07 Introduction Dear Consumer: We would like to thank you for purchasing this JourneyMan® product. We at DESA Specialty Products™ feel that you have purchased the most durable motion sensor available today. This JourneyMan® product will give you a lifetime worth of operation. We are so confident with the durability of this product that we are backing it with a Lifetime Warranty. Enhanced Performance Features . Rugged gripping teeth and finger screw provide full three-dimension adjustment of sensor head. . Eight silicon rubber gaskets seal internal components and controls from severe environmental conditions. . Stainless steel screws to prevent rust and corrosion. . Built in 1.25 Mega Watt surge protection. . A.S.I.C. (Application Specific Integrated Circuit) design allows more reliable performance. . Range Boost option to extend range for those hard to cover areas. . Extremely wide angle coverage (up to 270°). . Easy to control other lights with your JourneyMan® fixture (up to 1000 Watts total load). . Expanded lens area receives more infrared light improving detection sensitivity. . Pulse count technology reduces false sensing from wind and rain for professional reliability. . Automatic photocell deactivates unit in daylight to save energy. . Power outage reset. Turns light off automatically if turned on by power interruption or electrical storm. . Selectable light timer to set the time lights stay on after motion has been detected. . Sensitivity control allows adjustment of coverage range. . Manual override to turn lights on/off at your convenience with existing indoor wall switch. 595-5631-07 -3 Package Contents Additional Items Needed • Motion Sensor Light Fixture • Lens shield • Manual • Hardware Pack Gasket Hanger 1 Universal adaptor plate 4Wire nuts 2 #6-32 X 3/4" (19 mm) screws (for small rectangular boxes) 2 #8-32 X 3/8" (10 mm) screws (fixture to universal adaptor) 4 #8-32 X 3/4" (19 mm) screws (for circular or octagon boxes) 2 #10-24 X 1/2" (13 mm) screws (for water tight boxes) • Phillips screwdriver • Ladder • 2 Flood lamps, 150 Watts Maximum per lamp Fits All Junction Box Configurations Circular Horizontal rectangular Vertical rectangular Octagon -4- 595-5631-07 Installation CAUTION: BEFORE STARTING THE INSTALLATION, TURN THE POWER OFF AT THE CIRCUIT BREAKER. If you want to use the Manual Override feature you will need to install the fixture on a circuit controlled by a switch. Wall Mount Eave Mount . Loosen the thumbscrews holding the sensor . Loosen the thumbscrews holding the sensor head and lampheads. head and lampheads. . Adjust the various parts so that the fixture . Adjust the various parts so that the fixture looks similar to this illustration. looks similar to this illustration. . Finger tighten the thumbscrews at this time. . Finger tighten the thumbscrews at this time. 595-5631-07 -5 Universal Adaptor Standard Wiring If you are mounting the JourneyMan® fixture to a small rectangular box, you will need to use the universal adaptor as shown below. Other boxes may require the adaptor adjusted differently. If you are using a standard octagon box, the adaptor is probably not required. Use these holes and the #832 X 3/8" (10 mm) screws provided to secure the fixture. #6-32 screw CAUTION: If you have not already turned the power off at the breaker or fuse, do so now. Make sure the gasket is in place before connecting any wires. You may find it convenient to use the wire hanger provided to hold the fixture to the junction box during the wiring process. Connect the junction box wires to the fixture wires. Twist together and secure with wire...

Questo manuale è adatto anche per i modelli :
Video - JOURNEYMAN HD-9240 (826.6 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie