Log:
valutazioni - 2, GPA: 4 ( )

Istruzioni per l'uso Rinnai, Modello QPA-09-0007

Produttore : Rinnai
File Size : 4.59 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


The drawing doesnot imply compliance with local building code requirements. It is theresponsibility of the engineer or contractor to ensure that the installation isin accordance with all local building codes. Confer with local buildingofficials before installation. 3 BC 120VLow voltage Q Series boilers2 boilers with DHW indirect tank123456910111213141516171819202122262DonotapplypowertN1/ tN2Com10KUnOSwComOutBoilDHW10A10AStageStage112210A10APowerNLP1BoilDHWPmp/ VlvBoilerDemandDemComDHWDemSetpDem87Boiler 2 Boiler 1 120VInput HeatingCirculator DHWCirculator DHWSensorOutdoorSensorOutdoorSensor120VInput SupplySensorOutdoorSensorNLHeat Demand FromThermostat/ zone control NL Note: See 2 boiler with DHW indirecttank drawing 120V RelayTPST 23 6 91 118 10 212223B1213CHDHW14151617192018NACylinder connectionThree way valve DHWsensor OutsideSensor BusController RoomTherm. On/ Off 212223B1213CHDHW14151617192018NACylinder connectionThree way valve DHWsensor OutsideSensor BusController RoomTherm. On/Off QEC-09- 0001 21 Boiler Applications Manual 800000026 Rev B A 4 B 3 CD 4 2 SCALESIZEDATE 1 SHEET DWG NO. REV A 2 1 D Approved By NTS BA 12/09/ 09EL Q Series BoilerSingle Zone Circuit with Priority DHW This drawing is the exclusiveproperty of Rinnai America Corporation, it may not bereproduced or given to third parties. 1 of 1 Rinnai America Corporation103 International DrivePeachtree City, GA 302691- 800- 621- 9419 Drawn By JG Tolerance Fraction = ± 1/ 16" x.x= ± 0.030x.xx= ± 0.015x.xxx= ± 0.005 This is not an engineering drawing; it is intended only as a guide and notas a replacement for professional engineering project drawings. Thisdrawing is not intended to describe a complete system. It is up to thecontractor or engineer to determine the necessary components andconfiguration of the particular system to be installed. The drawing doesnot imply compliance with local building code requirements. It is theresponsibility of the engineer or contractor to ensure that the installation isin accordance with all local building codes. Confer with local buildingofficials before installation. 3 BC 53H 4 N/ O 4 N/ C 6N/ O N N/ C 6 120 VACINPUT TT COM WR 24VAC 53H 4 N/ O 4 N/ C 6N/ O N N/ C 6 120 VACINPUT TT COM WR 24VAC T stat 120V DHWPump ZonePump DHWPumpRelay HeatingPumpRelay* * May substitute for multizone relay 120VLow voltage Q boilerSingle Zone Circuit with Priority DHWNote: See pipingdiagram Single ZonePriority DHW AquastatForDHW 21 22 23 24 26 2725 B 1 2 3 4 6 75 8 9 10 12 1311 N L LN N L N CH DHW L 14 15 16 17 19 2018 N A 120VPower supply 120VExternal pump 120VExternalcontroller 120V Cylinder connectionThree way valve DHWsensor OutsideSensor BusController RoomTherm. On/Off ExternalSafetycontact 24V~ 100mA QED-09- 0001 A 4 B 3 CD 4 2 SCALESIZEDATE 1 SHEET DWG NO. REV A 2 1 D Approved By NTS BA 12/09/ 09EL Q Series BoilerSingle Zone Circuit with Priority DHW This drawing is the exclusiveproperty of Rinnai America Corporation, it may not bereproduced or given to third p...

Questo manuale è adatto anche per i modelli :
scaldabagno - QPA-09-0002 (4.59 mb)
scaldabagno - QPA-09-0001 (4.59 mb)
scaldabagno - QPA-09-0003 (4.59 mb)
scaldabagno - QPA-09-0004 (4.59 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie