Facilità d'uso
DON’T ¦ DON’T block or restrict Combustion Air Inlet Openings located around the lower portion of the water heater jacket. ¦ DON’T remove the Burner Access Door unless absolutely necessary. This should only be done by a qualified service technician. A new burner access door gasket must be installed on any burner access door that has been removed. ¦ DON’T install this water heater where standing water may occur. The base of the water heater is meant to be mounted on a dry surface. ¦ DON’T operate the water heater if the sight glass or burner access door grommet is damaged or broken. Hot and Cold Pipe Insulation Installation For increased energy efficiency, some water heaters have been supplied with two 24” sections of pipe insulation. Please install the insulation, according to the illustrations above, that best meets your requirements. Sight Glass Burner Access Door Grommet Installation checklist. Customer Service Troubleshooting Tips Care and Cleaning Operating Instructions Installation Instructions Safety Instructions Water Heater Location ¦ Close to area of vent. ¦ Indoors and protected from freezing temperatures. ¦ Proper clearance from combustible surfaces observed and water heater not installed on carpeted floor. ¦ Sufficient fresh air supply for proper operation of water heater. ¦ Air supply free of corrosive elements and flammable vapors. ¦ Provisions made to protect area from water damage. ¦ Sufficient room to service heater. ¦ Combustible materials, such as clothing, cleaning materials, rags, etc. clear of the base of the heater. ¦ Clearances from combustion air inlet openings observed (see page 7). Water Supply ¦ Water heater completely filled with water. ¦ Air purged from water heater and piping. ¦ Water connections tight and free of leaks. Gas Supply ¦ Gas line equipped with shut-off ¦ Soap and water solution used to valve, union and sediment trap. check all connections and fittings for possible gas leak. ¦ Approved pipe joint compound used. ¦ Gas Company inspected installation (if required). Relief Valve ¦ Temperature and Pressure Relief Valve properly installed and discharge line run to open drain. ¦ Discharge line protected from freezing. Venting ¦ Flue baffle properly hung in top of heater’s flue. ¦ Draft hood properly installed. ¦ Vent connector(s) pitched upward to chimney (1/4” per foot of length minimum). ¦ Vent connector(s) securely fastened together with screws. ¦ Single wall vent connector(s) at least 6” from combustible material. 14 Safety Instructions Installation Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Customer Service Local codes or plumbing authority requirements may vary from the instructions or diagrams provided in this manual and take precedent over these instructions. Tee fitting for vertical hot water supply lines Combination Potable and Space Heating Application Tee fitting must be installed as shown. This ensures that any air in the water lines will be purged through the domestic water faucets and showers. DANGER: When this system requires water for space heating at elevated temperatures (above 125°F [52°C]), a mixing or tempering valve must be installed in the hot water supply line to the house in order to reduce the scald hazard potential. DANGER: Any piping or components used in the installation of this water heater in a combination potable and space heating application must be suitable for use with drinking water. DANGER: If this water heater is installed in an application intended to supply domestic hot water needs and hot water for space heating purposes, do not connect the heater to an existing heating unit or components of a heating system that have previously been used with a non drinking water system. Toxic chemicals such as those used for boiler treatment may be present and will contaminate the drinking water supply causing possible health risks. Never introduce toxic chemicals, such as those used for boiler treatment, into this system. ! ! ! Tee fitting for horizontal hot water supply lines Hot water supply to house From HOT outlet on water heater From HOT outlet on water heater Hot water supply to heating unit Hot water supply to house Hot water supply to heating unit R E L I E F V A L V E COLD HOT Typical Piping Diagram for Combination Potable/Space Heating Installation Spring loaded check valve in heating unit hot water supply line and cold water return line (not supplied with water heater) NOTICE: This check valve is incorporated in some heating units. Refer to the installation instructions supplied with specific heating unit to determine if it is required. See diagrams above for proper pipe application for vertical or horizontal supply lines Gas line to water heater Cold water return line from heating unit Hot water supply line into heating unit Heating unit Isolation valve in cold water return line from heating unit (not supplied with water heater) Water heater jacket Temperature and pressure relief valve discharge line...
Questo manuale è adatto anche per i modelli :scaldabagno - AP13204-4 (1.53 mb)
scaldabagno - HG Series (1.53 mb)
scaldabagno - GP Series (1.53 mb)
scaldabagno - GG Series (1.53 mb)